A comparison of capillary electrophoresis using indirect UV absorbance and ICP-MS detection with a self-aspirating nebulizer interface

被引:47
|
作者
Day, JA
Sutton, KL
Soman, RS
Caruso, JA [1 ]
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
[2] Univ Cincinnati, Dept Chem Technol, Cincinnati, OH 45206 USA
关键词
D O I
10.1039/a910268j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A comparison of capillary electrophoresis (CE) migration times using standard on-column UV detection and inductively coupled plasma mass spectrometry (ICP-MS) is presented for two different CE separations. The first is a separation of five arsenic compounds, four anionic species and one neutral, using reverse polarity in a chromate buffer with an electroosmotic flow modifier. The second CE separation employs normal polarity for the separation of eleven lanthanide cations using a hydroxyisobutyric acid (HIBA) buffer with an indirect UV detection reagent. The CE-ICP-MS interface is based on a tee design which introduces a sheath flow around the CE capillary using a self-aspirating make-up electrolyte with a microconcentric nebulizer (MCN-100). Migration times observed for CE-ICP-MS electropherograms are comparable to migration times acquired with UV detection, and may be adjusted by changes in the make-up liquid level position. The precision of peak areas (< 2%) and migration times (< 4%) obtained using CE-ICP-MS is comparable to that obtained using online UV absorbance detection. CE-ICP-MS limits of detection are in the low ng ml(-1) range for the analytes studied.
引用
收藏
页码:819 / 823
页数:5
相关论文
共 50 条
  • [31] Detection of transferrin isoforms in human serum:: comparison of UV and ICP-MS detection after CZE and HPLC separations
    Rodríguez, SA
    González, EB
    Llamas, GA
    Montes-Bayón, M
    Sanz-Medel, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (03) : 390 - 397
  • [32] Capillary electrophoresis analysis of peptides and proteins using a polyethyleneimine-coated capillary with UV and MS detection
    Jayo, Roxana G.
    Chen, David D. Y.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [33] Determination of arsenic speciation by capillary electrophoresis and ICP-MS using a movable reduction bed hydride generation system
    Tian, XD
    Zhuang, ZX
    Chen, B
    Wang, XR
    ATOMIC SPECTROSCOPY, 1999, 20 (04) : 127 - 133
  • [34] Interface development for coupling capillary electrophoresis (CE) and inductively coupled plasma - Mass spectrometry (ICP-MS): Application to plutonium speciation
    Baglan, N
    Delorme, A
    Aupiais, J
    PLUTONIUM FUTURES - THE SCIENCE, 2003, 673 : 393 - 395
  • [35] Separation and Determination of Carbohydrates in Food Samples by Capillary Electrophoresis Using Dynamically Coating the Capillary with Indirect UV Detection
    Ting-Fu Jiang
    Lei Chong
    Mei-E Yue
    Yuan-Hong Wang
    Zhi-Hua Lv
    Food Analytical Methods, 2015, 8 : 2588 - 2594
  • [36] Separation and Determination of Carbohydrates in Food Samples by Capillary Electrophoresis Using Dynamically Coating the Capillary with Indirect UV Detection
    Jiang, Ting-Fu
    Chong, Lei
    Yue, Mei-E
    Wang, Yuan-Hong
    Lv, Zhi-Hua
    FOOD ANALYTICAL METHODS, 2015, 8 (10) : 2588 - 2594
  • [37] Analysis of sugar phosphates and related compounds using capillary zone electrophoresis with indirect UV detection
    Ciringh, Y
    Lindsey, JS
    JOURNAL OF CHROMATOGRAPHY A, 1998, 816 (02) : 251 - 259
  • [38] QUANTITATIVE-DETERMINATION OF ORGANIC-SOLVENTS BY CAPILLARY ELECTROPHORESIS USING INDIRECT UV DETECTION
    ALTRIA, KD
    HOWELLS, JS
    JOURNAL OF CHROMATOGRAPHY A, 1995, 696 (02) : 341 - 348
  • [39] DETERMINATION OF QUATERNARY AMMONIUM-COMPOUNDS BY CAPILLARY ELECTROPHORESIS USING DIRECT AND INDIRECT UV DETECTION
    WEISS, CS
    HAZLETT, JS
    DATTA, MH
    DANZER, MH
    JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2): : 325 - 332
  • [40] Determination of small anions by capillary electrophoresis using indirect UV detection with sulphonated nitrosonaphthol dyes
    Siren, H
    Maattanen, A
    Riekkola, ML
    JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) : 293 - 301