Repeated 3D coronary MR angiography with navigator echo gating: Technical quality and consistency of image interpretation

被引:8
|
作者
Ikonen, AEJ
Manninen, HI
Vainio, P
Hirvonen, TPJ
Vanninen, RL
Matsi, PJ
Hartikainen, JEK
机构
[1] Kuopio Univ Hosp, Dept Clin Radiol, SF-70210 Kuopio, Finland
[2] Kuopio Univ Hosp, Dept Med, SF-70210 Kuopio, Finland
关键词
heart; vessels; arteries; coronary; stenosis; magnetic resonance imaging;
D O I
10.1097/00004728-200005000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the technical quality of 3D coronary MR angiography (CMRA) with navigator echo and the consistency of image interpretation in repeated imaging sessions. Fourteen subjects underwent CMRA, 10 of whom were imaged twice. The coronary arteries (96 segments) were analyzed twice for hemodynamically significant stenoses. Signal-to-noise and contrast-to-noise ratios varied considerably between the two imagings. Fat saturation was poor or satisfactory in 37%; in 15% of the slabs, the severity of artifacts was moderate; and the overall quality was good to excellent in only 42% of the imagings. The intraobserver reproducibility was good (kappa = 0.54), but the consistency of interpretation for repeated CMRA was only satisfactory (kappa = 0.43). Sensitivities of 84 and 84% and specificities of 70 and 62% were obtained for the two readings. Although the reproducibility of image reading is good, 3D CMRA with navigator echo provides only fair technical consistency, and the frequently compromised image quality impairs the clinical utility of this technique.
引用
收藏
页码:375 / 381
页数:7
相关论文
共 50 条
  • [21] Intraindividual comparison of 3D coronary MR angiography and coronary CT angiography
    Ozgun, Murat
    Rink, Michael
    Hoffmeier, Andreas
    Botnar, Rene M.
    Heindel, Walter
    Fischbach, Roman
    Maintz, David
    ACADEMIC RADIOLOGY, 2007, 14 (08) : 910 - 916
  • [22] Improved magnetization preparation for navigator steady-state free precession 3D coronary MR angiography
    Nguyen, TD
    Spincemaille, P
    Wang, Y
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (06) : 1297 - 1300
  • [23] MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique
    Langreck, H
    Schnackenburg, B
    Nehrke, K
    Boernert, P
    Wahl, A
    Paetsch, I
    Bornstedt, A
    Fleck, E
    Nagel, E
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (05) : 793 - 797
  • [24] Evaluation of coronary by-pass grafts patency with plain 3D navigator echo and breath-hold Gd-enhanced FISP MR angiography
    Parodi, R
    Sardanelli, F
    Molinari, G
    Caratti, A
    Zandrino, F
    Bruzzone, F
    RADIOLOGY, 1997, 205 : 53 - 53
  • [25] Comparison of gradient-echo and steady state free precession sequences for 3D-navigator MR angiography of coronary arteries
    Barkhausen, J
    Hunold, P
    Jochims, M
    Eggebrecht, H
    Sabin, GV
    Erbel, R
    Debatin, JF
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06): : 725 - 730
  • [26] Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator
    Henningsson, Markus
    Smink, Jouke
    Razavi, Reza
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 486 - 494
  • [27] The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography
    Spuentrup, E
    Stuber, M
    Botnar, RM
    Manning, WJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) : 311 - 318
  • [28] Submillimeter 3D coronary MR angiography with real-time navigator correction in 107 patients with suspected coronary artery disease
    Sommer, T
    Hofer, U
    Hackenbroch, M
    Meyer, C
    Flacke, S
    Schmiedel, A
    Schmitz, C
    Thiemann, K
    Omran, H
    Schild, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (04): : 459 - 466
  • [29] Angle-independent measure of motion for image-based gating in 3D coronary angiography
    Lehmann, Glen C.
    Holdsworth, David W.
    Drangova, Maria
    MEDICAL PHYSICS, 2006, 33 (05) : 1311 - 1320
  • [30] Accelerated isotropic resolution 3D image-based navigators for coronary MR angiography
    Nii O Addy
    Jieying Luo
    R Reeve Ingle
    Bob S Hu
    Dwight G Nishimura
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)