Repeated 3D coronary MR angiography with navigator echo gating: Technical quality and consistency of image interpretation

被引:8
|
作者
Ikonen, AEJ
Manninen, HI
Vainio, P
Hirvonen, TPJ
Vanninen, RL
Matsi, PJ
Hartikainen, JEK
机构
[1] Kuopio Univ Hosp, Dept Clin Radiol, SF-70210 Kuopio, Finland
[2] Kuopio Univ Hosp, Dept Med, SF-70210 Kuopio, Finland
关键词
heart; vessels; arteries; coronary; stenosis; magnetic resonance imaging;
D O I
10.1097/00004728-200005000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the technical quality of 3D coronary MR angiography (CMRA) with navigator echo and the consistency of image interpretation in repeated imaging sessions. Fourteen subjects underwent CMRA, 10 of whom were imaged twice. The coronary arteries (96 segments) were analyzed twice for hemodynamically significant stenoses. Signal-to-noise and contrast-to-noise ratios varied considerably between the two imagings. Fat saturation was poor or satisfactory in 37%; in 15% of the slabs, the severity of artifacts was moderate; and the overall quality was good to excellent in only 42% of the imagings. The intraobserver reproducibility was good (kappa = 0.54), but the consistency of interpretation for repeated CMRA was only satisfactory (kappa = 0.43). Sensitivities of 84 and 84% and specificities of 70 and 62% were obtained for the two readings. Although the reproducibility of image reading is good, 3D CMRA with navigator echo provides only fair technical consistency, and the frequently compromised image quality impairs the clinical utility of this technique.
引用
收藏
页码:375 / 381
页数:7
相关论文
共 50 条
  • [1] Navigator echo ECG triggered coronary MRA: Reproducibility of image interpretation and consistency of technical quality in two repeated imaging sessions
    Ikonen, AE
    Manninen, HI
    Hartikainen, JE
    Hirvonen, TP
    Vanninen, RL
    Vainio, PA
    RADIOLOGY, 1998, 209P : 306 - 306
  • [2] Navigator-echo-based respiratory gating for 3D-MR coronary angiography
    Valassis, G
    Nikolaou, K
    Gonschior, P
    Huber, A
    Reiser, M
    EUROPEAN HEART JOURNAL, 2000, 21 : 509 - 509
  • [3] A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography
    Du, YPP
    McVeigh, ER
    Bluemke, DA
    Silber, HA
    Foo, TKF
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2001, 17 (04): : 287 - 294
  • [4] A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography
    Yiping P. Du
    Elliot R. McVeigh
    David A. Bluemke
    Harry A. Silber
    Thomas K.F. Foo
    The International Journal of Cardiovascular Imaging, 2001, 17 : 287 - 294
  • [5] 3D navigator echo MR coronary angiography (MRCA) in detecting stenoses of major epicardial coronary arteries
    Sardanelli, F
    Parodi, RC
    Molinari, G
    Guglielmino, G
    Rescinito, G
    Caponnetto, S
    RADIOLOGY, 1997, 205 : 51 - 51
  • [6] A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography - Editorial comment
    Bunce, NH
    Jhooti, P
    Underwood, SR
    Pennell, DJ
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2001, 17 (04): : 295 - 296
  • [7] 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography
    Hackenbroch, M
    Nehrke, K
    Gieseke, J
    Meyer, C
    Tiemann, K
    Litt, H
    Dewald, O
    Naehle, CP
    Schild, H
    Sommer, T
    EUROPEAN RADIOLOGY, 2005, 15 (08) : 1598 - 1606
  • [8] 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography
    M. Hackenbroch
    K. Nehrke
    J. Gieseke
    C. Meyer
    K. Tiemann
    H. Litt
    O. Dewald
    C. P. Naehle
    H. Schild
    T. Sommer
    European Radiology, 2005, 15 : 1598 - 1606
  • [9] 3D MR angiography of pulmonary arteries using realtime navigator gating and magnetization preparation
    Wang, Y
    Rossman, PJ
    Grimm, RC
    Wilman, AH
    Riederer, SJ
    Ehman, RL
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 579 - 587
  • [10] Prospective navigator gating with a dual acceptance window technique to reduce respiratory motion artifacts in 3D MR coronary angiography
    Du, YPP
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (02): : 157 - 162