Amperometric sensing of catechol using a glassy carbon electrode modified with ferrocene covalently immobilized on graphene oxide

被引:45
|
作者
Elancheziyan, Mari [1 ]
Manoj, Devaraj [1 ]
Saravanakumar, Duraisamy [1 ]
Thenmozhi, Kathavarayan [1 ]
Senthilkumar, Sellappan [1 ]
机构
[1] VIT Univ, Sch Adv Sci, Dept Chem, Vellore 632014, Tamil Nadu, India
关键词
Electrochemical sensor; Nonenzymatic sensor; Cyclic voltammetry; Electrochemical impedance spectroscopy; Silanization; Water analysis; GOLD NANOPARTICLES; FUNCTIONALIZED GRAPHENE; AU NANOPARTICLES; QUANTUM DOTS; COMPOSITE; ACID; POLYDOPAMINE; TYROSINASE; BIOSENSOR;
D O I
10.1007/s00604-017-2312-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors report on a nonenzymatic catechol sensor that is based on the immobilization of ferrocene (Fc) on graphene oxide (GO). A glassy carbon electrode (GCE) was modified with GO which then was silanized with (3-aminopropyl) trimethoxysilane. Ferrocenecarboxaldehyde was then immobilized on GO via formation of a Schiff base. The immobilization process was monitored stepwise by using FTIR spectroscopy, X-ray diffraction, cyclic voltammetry (CV) and electrochemical impedance spectroscopy. Investigation of the modified electrode by CV revealed a pair of well- defined redox peaks with anodic and cathodic peak potentials at +0.380 and +0.277 V, corresponding to the Fc/Fc(+) redox couple. The Fc modified electrode exhibits excellent electrocatalytic activity towards the oxidation of catechol at a typical working voltage of +0.45 V (vs. Ag/AgCl). The response is linear in the 3 to 112 mu M catechol concentration range, the detection limit is 1.1 mu M, and the sensitivity is 1184.3 mu A.mM(-1).cm(-2). The sensor is stable, reproducible and reasonably selective. It was successfully applied to the determination of catechol in spiked tap water and lake water samples.
引用
收藏
页码:2925 / 2932
页数:8
相关论文
共 50 条
  • [41] A glassy carbon electrode modified with graphene oxide decorated silver phosphate nanodentrites for amperometric determination of dissolved hydrazine
    Kohila rani Karuppasamy
    Rajkumar Devasenathipathy
    Sea-Fue Wang
    Microchimica Acta, 2017, 184 : 2569 - 2577
  • [42] Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion
    Yusoff, Norazriena
    Rameshkumar, Perumal
    Shahid, Muhammad Mehmood
    Huang, Sheng-Tung
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2017, 184 (09) : 3291 - 3299
  • [43] Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion
    Norazriena Yusoff
    Perumal Rameshkumar
    Muhammad Mehmood Shahid
    Sheng-Tung Huang
    Nay Ming Huang
    Microchimica Acta, 2017, 184 : 3291 - 3299
  • [44] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Wang, Yazhen
    Song, Bin
    Xu, Junhui
    Hu, Shengshui
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 711 - 718
  • [45] Sensing of doxorubicin hydrochloride using graphene quantum dot modified glassy carbon electrode
    Hasanzadeh, Mohammad
    Hashemzadeh, Nastaran
    Shadjou, Nasrin
    Eivazi-Ziaei, Jamal
    Khoubnasabjafari, Maryam
    Jouyban, Abolghasem
    JOURNAL OF MOLECULAR LIQUIDS, 2016, 221 : 354 - 357
  • [46] Self-assembled Graphene for Determination of Catechol in Wastewater at Modified Glassy Carbon Electrode
    Chen, Meifeng
    Ma, Xinying
    Li, Xia
    ADVANCED MATERIALS AND ENGINEERING APPLICATIONS, 2012, 161 : 255 - 259
  • [47] Graphene-based Heterostructure Modified Glassy Carbon Electrode for Sensitive Detection of Catechol
    Lei, Peng
    Wei, Peng-Jia
    Wu, Ni
    Li, Ming-Lu
    Shuang, Shao-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2025, 53 (01) : 65 - 73
  • [48] Electrochemical determination of caffeine in beverage using graphene oxide modified glassy carbon electrode
    Murugan, E.
    Poongan, A.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2021, 28 (05) : 528 - 536
  • [49] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Sharma, Vimal
    Hynek, David
    Trnkova, Libuse
    Hemzal, Dusan
    Marik, Marian
    Kizek, Rene
    Hubalek, Jaromir
    MICROCHIMICA ACTA, 2016, 183 (04) : 1299 - 1306
  • [50] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Vimal Sharma
    David Hynek
    Libuse Trnkova
    Dusan Hemzal
    Marian Marik
    Rene Kizek
    Jaromir Hubalek
    Microchimica Acta, 2016, 183 : 1299 - 1306