Amperometric sensing of catechol using a glassy carbon electrode modified with ferrocene covalently immobilized on graphene oxide

被引:45
|
作者
Elancheziyan, Mari [1 ]
Manoj, Devaraj [1 ]
Saravanakumar, Duraisamy [1 ]
Thenmozhi, Kathavarayan [1 ]
Senthilkumar, Sellappan [1 ]
机构
[1] VIT Univ, Sch Adv Sci, Dept Chem, Vellore 632014, Tamil Nadu, India
关键词
Electrochemical sensor; Nonenzymatic sensor; Cyclic voltammetry; Electrochemical impedance spectroscopy; Silanization; Water analysis; GOLD NANOPARTICLES; FUNCTIONALIZED GRAPHENE; AU NANOPARTICLES; QUANTUM DOTS; COMPOSITE; ACID; POLYDOPAMINE; TYROSINASE; BIOSENSOR;
D O I
10.1007/s00604-017-2312-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors report on a nonenzymatic catechol sensor that is based on the immobilization of ferrocene (Fc) on graphene oxide (GO). A glassy carbon electrode (GCE) was modified with GO which then was silanized with (3-aminopropyl) trimethoxysilane. Ferrocenecarboxaldehyde was then immobilized on GO via formation of a Schiff base. The immobilization process was monitored stepwise by using FTIR spectroscopy, X-ray diffraction, cyclic voltammetry (CV) and electrochemical impedance spectroscopy. Investigation of the modified electrode by CV revealed a pair of well- defined redox peaks with anodic and cathodic peak potentials at +0.380 and +0.277 V, corresponding to the Fc/Fc(+) redox couple. The Fc modified electrode exhibits excellent electrocatalytic activity towards the oxidation of catechol at a typical working voltage of +0.45 V (vs. Ag/AgCl). The response is linear in the 3 to 112 mu M catechol concentration range, the detection limit is 1.1 mu M, and the sensitivity is 1184.3 mu A.mM(-1).cm(-2). The sensor is stable, reproducible and reasonably selective. It was successfully applied to the determination of catechol in spiked tap water and lake water samples.
引用
收藏
页码:2925 / 2932
页数:8
相关论文
共 50 条
  • [1] Amperometric sensing of catechol using a glassy carbon electrode modified with ferrocene covalently immobilized on graphene oxide
    Mari Elancheziyan
    Devaraj Manoj
    Duraisamy Saravanakumar
    Kathavarayan Thenmozhi
    Sellappan Senthilkumar
    Microchimica Acta, 2017, 184 : 2925 - 2932
  • [2] Amperometric Sensing of Hydrogen Peroxide Using Graphene Oxide-Alizarin Modified Glassy Carbon Electrode
    Muhammet, Sinan Mithat
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):
  • [3] Photoelectrochemical amperometric sensing of cyanide using a glassy carbon electrode modified with graphene oxide and titanium dioxide nanoparticles
    Rahman Hallaj
    Nasibeh Haghighi
    Microchimica Acta, 2017, 184 : 3581 - 3590
  • [4] Photoelectrochemical amperometric sensing of cyanide using a glassy carbon electrode modified with graphene oxide and titanium dioxide nanoparticles
    Hallaj, Rahman
    Haghighi, Nasibeh
    MICROCHIMICA ACTA, 2017, 184 (09) : 3581 - 3590
  • [5] Amperometric Determination of Acetaminophen (paracetamol) Using Graphene Oxide Modified Glassy Carbon Electrode
    Alagarsamy, Periyalagan
    Settu, Ramki
    Chen, Shen-Ming
    Chen, Tse-Wei
    Hong, In-Seok
    Rao, Mettu Mallikarjuna
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (08): : 7930 - 7938
  • [6] Amperometric sensing of hydroquinone using a glassy carbon electrode modified with a composite consisting of graphene and molybdenum disulfide
    Huayu Huang
    Jiangyi Zhang
    Meimei Cheng
    Kunping Liu
    Xingyu Wang
    Microchimica Acta, 2017, 184 : 4803 - 4808
  • [7] Amperometric sensing of hydroquinone using a glassy carbon electrode modified with a composite consisting of graphene and molybdenum disulfide
    Huang, Huayu
    Zhang, Jiangyi
    Cheng, Meimei
    Liu, Kunping
    Wang, Xingyu
    MICROCHIMICA ACTA, 2017, 184 (12) : 4803 - 4808
  • [8] Ferrocene/graphene modified glassy carbon electrode for Chloromycetin detection
    Hu, Lin
    Zhou, Xiaoqin
    Li, Jinqing
    Bai, Tongtong
    Tang, Juan
    Zhou, Tao
    Cui, Qujin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (01): : 396 - 409
  • [9] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    Noor, An'amt Mohamed
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2016, 183 (02) : 911 - 916
  • [10] Amperometric sensing of ascorbic acid by using a glassy carbon electrode modified with mesoporous carbon nanorods
    Li, Xiuxiu
    Liu, Jingju
    Sun, Mimi
    Sha, Tianze
    Bo, Xiangjie
    Zhou, Ming
    MICROCHIMICA ACTA, 2018, 185 (10)