The effect of positional realignment on dose delivery to the prostate and organs-at-risk for 3DCRT

被引:19
|
作者
Wang, Zhou [1 ]
Rajagopalan, Balu [1 ]
Malhotra, Harish K. [1 ]
Kuettel, Michael R. [1 ]
Podgorsak, Matthew B. [1 ]
机构
[1] Roswell Pk Canc Inst, Dept Radiat Med, Buffalo, NY 14263 USA
关键词
prostate carcinoma; organ motion; ultrasound guidance; 3D conformal radiotherapy; BEAM RADIATION-THERAPY; RADIOTHERAPY; CANCER; MOTION; MARKERS; DISTRIBUTIONS; LOCALIZATION; CARCINOMA;
D O I
10.1016/j.meddos.2006.08.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In this study, we evaluate the impact of daily image-guided patient repositioning on dose delivery to prostate and sensitive organs in the treatment of prostate carcinoma with 3-dimensional conformal radiation therapy (3DCRT). Five patients with substantial ultrasound-documented interfractional prostate motion during their 3DCRT treatment course were selected. Starting with the original treatment plan, 2 additional plans were retrospectively generated for each patient. In one set, organ contours were moved for each fraction, thus simulating positioning with misalignment caused by organ motion if ultrasound guidance were not used. In a second set of plans, the isocenter was shifted, as were the organ contours, simulating realignment based on the ultrasound image. In all cases, the number of planned monitor units was set to those of the original plan. For a given patient, isodose distributions, dose-volume histograms (DVHs), equivalent uniform dose (EUD) for prostate, and generalized equivalent uniform dose (gEUDs) for bladder and rectum were calculated for each fraction and then combined for each shift condition. In all reconstructed plans, the results show no substantial changes in dose coverage of the prostate (< 0.21 % change in EUD) compared to the original plan. However, in some cases with no realignment, a larger volume of the bladder or rectum gets higher dose, with the consequent gEUD for each organ significantly greater compared to the original plan. (C) 2007 American Association of Medical Dosimetrists.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [32] Outcome of prostate cancer patients treated with 3DCRT: impact of rectal/bladder preparation
    Maggio, A.
    Garibaldi, E.
    Gabriele, D.
    Bresciani, S.
    Delmastro, E.
    Di Dia, A.
    Miranti, A.
    Poli, M.
    Gabriele, P.
    Stasi, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S351 - S352
  • [33] Hypofractionation with VMAT versus 3DCRT in Post-operative Patients with Prostate Cancer
    Alongi, Filippo
    Cozzi, Luca
    Fogliata, Antonella
    Iftode, Cristina
    Comito, Tiziana
    Clivio, Alessandro
    Villa, Elisa
    Lobefalo, Francesca
    Navarria, Piera
    Reggiori, Giacomo
    Mancosu, Pietro
    Clerici, Elena
    Tomatis, Stefano
    Taverna, Gianluigi
    Graziotti, Pierpaolo
    Scorsetti, Marta
    ANTICANCER RESEARCH, 2013, 33 (10) : 4537 - 4543
  • [34] Toxicity evaluation in adjuvant hypofractionated IMRT versus conventional 3DCRT in prostate cancer
    Russo, D.
    Leone, A.
    Papaleo, A.
    Cavalera, E.
    Di Paola, G.
    Ricci, F. P.
    Chiuri, V. E.
    Accettura, C.
    Santantonio, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S96 - S97
  • [35] MONITORING OF RADIOTHERAPY RESULTS USING 3DCRT TECHNIQUE FOR LOCAL PROSTATE CANCER WITH PSA
    Dorchin, M.
    Zein, Z. M.
    Chamssuddin, C. A. K.
    Soleiman, S. S.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2015, 25 (09) : 1545 - 1545
  • [36] THE CLINICAL IMPACT OF DIFFERENCES IN PHOTON DOSE ALGORITHMS: 3DCRT AND SBRT OF LUNG TUMOURS
    Chandrasekaran, M.
    Panettieri, V.
    Baker, C.
    Nahum, A. E.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S427 - S428
  • [37] Dose gradients for IMRT larger? - 3-D analysis of the generalized dose gradient for IMRT and 3DCRT plans
    Fraass, B
    McShan, D
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S41 - S42
  • [38] IMRT versus conventional 3DCRT on prostate and normal tissue dosimetry using an endorectal balloon for prostate immobilization
    Vlachaki, MT
    Teslow, TN
    Amosson, C
    Uy, NW
    Ahmad, S
    MEDICAL DOSIMETRY, 2005, 30 (02) : 69 - 75
  • [39] DOSE-EFFECT RELATIONSHIPS FOR ORGANS-AT-RISK RELATED TO EMPTYING OF ALL STOOLS INTO CLOTHING WITHOUT FOREWARNING
    Alevronta, E.
    Lind, H.
    Al-Abany, M.
    Waldenstrom, A. C.
    Olsson, C.
    Dunberger, G.
    Mavroidis, P.
    Onelov, E.
    Nyberg, T.
    Johansson, K. A.
    Avall-Lundqvist, E.
    Steineck, G.
    Lind, B.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S98 - S98
  • [40] Is there a role for radiation therapists in the delineation of organs-at-risk in conformal radiotherapy for prostate cancer?
    Fitzpatrick, K
    Kelly, C
    Thirion, P
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S99 - S100