Parameter analysis of Earth-air heat exchangers over multi-layered soils in South Brazil

被引:14
|
作者
Domingues, A. M. B. [1 ]
Nobrega, E. S. B. [1 ]
Ramalho, J. V. A. [1 ]
Brum, R. S. [1 ]
Quadros, R. S. [1 ]
机构
[1] Univ Fed Pelotas UFPel, Programa Posgrad Modelagem Matemat, Campus Capao Leao S-N, BR-96160000 Pelotas, RS, Brazil
关键词
Earth-air heat exchanger; Multi-layered soils; Thermal performance; Numerical simulations; Sustainability; Parameter analysis;
D O I
10.1016/j.geothermics.2021.102074
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Earth-air heat exchangers (EAHE) represent a sustainable way to explore the soil to heat or cool buildings. Due to the Earth?s thermal inertia, its superficial layers can be used as a heat source or sink, respectively, in the winter or summer. Hence, the EAHE employ buried ducts where the air is forced to flow and exchange heat with the soil. Such devices demand little energy, as they can use low powered fans or passive techniques for natural convection. Recurrent issues in the literature of EAHE explore how to improve their performances by analyzing their operational parameters; soil, climate, and global economic prospects; the development and validation of complete or simplified simulation models. This paper presents parameter analysis of EAHE to increase their thermal potentials (which is also related to the efficiency and the prospects for thermal comfort) and the heat exchanges (linked with the economy) considering a Brazilian city in a subtropical climate. The research uses simulations based on a validated 1D model. It is compared with three others, including 3D ones, giving more accurate results. Unlike most works covering 1D models, the methodology proposed here allows the study of multi-layered soils. After assessing the soil temperature variations, the results point out that most of the local thermal potential is attainable at relatively low depths, with magnitude peaks of 5?C. The parameter analyses are focused on this target potential, addressing changes in the airspeed, length, and diameter of the ducts. For all cases, the goal was achieved, allowing to obtain annual efficiencies close to 90%. However, only the tests increasing the length also increased the quantity of heat exchanged (in about 20%) and, consequently, proved to be economically affordable.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Experimental and numerical analysis of an earth-air heat exchanger
    Vaz, Joaquim
    Sattler, Miguel A.
    dos Santos, Elizaldo D.
    Isoldi, Liercio A.
    ENERGY AND BUILDINGS, 2011, 43 (09) : 2476 - 2482
  • [22] Feasibility Study on the Application of Earth-Air Heat Exchangers in Archaeological Site Exhibition Facilities
    Fan, Liwen
    Zhang, Ruohan
    Xie, Huarong
    Xia, Changchang
    Li, Yonghui
    Hokoi, Shuichi
    MULTIPHYSICS AND MULTISCALE BUILDING PHYSICS, IBPC 2024, VOL 3, 2025, 554 : 179 - 184
  • [23] CLOSED GREENHOUSE HEATING IN AN ARID EGYPTIAN WINTER USING EARTH-AIR HEAT EXCHANGERS
    Hegazy, Anwar
    Subiantoro, Alison
    Norris, Stuart
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 11, 2021,
  • [24] Numerical and Experimental Analysis of an Earth-Air Heat Exchanger
    Diedrich, Carlos Henrique
    dos Santos, Gerson Henrique
    Carraro, Gustavo Chaves
    Dimbarre, Victor Vaurek
    Alves, Thiago Antonini
    ATMOSPHERE, 2023, 14 (07)
  • [25] Numerical Simulation of Vertical Helical Earth-Air Heat Exchangers: Multiobjective Performance Assessment
    Razera, Andre Luis
    Vaz, Igor Silva
    Kepes Rodrigues, Michel
    Domingues Dos Santos, Elizaldo
    Oliveira Rocha, Luiz Alberto
    Isoldi, Liércio Andre
    Defect and Diffusion Forum, 2024, 435 : 77 - 89
  • [26] Further realistic annual simulations of earth-air heat exchangers installations in a coastal city
    Hermes, V. F.
    Ramalho, J. V. A.
    Rocha, L. A. O.
    dos Santos, E. D.
    Marques, W. C.
    Costi, J.
    Rodrigues, M. K.
    Isoldi, L. A.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 37 (37)
  • [27] Buckling Analysis of Piles in Multi-Layered Soils
    Fenu, Luigi
    Congiu, Eleonora
    Deligia, Mariangela
    Giaccu, Gian Felice
    Hosseini, Alireza
    Serra, Mauro
    APPLIED SCIENCES-BASEL, 2021, 11 (22):
  • [28] Transient Models to Analyze the Influence of the Air Velocity and Ducts Diameter on the Performance of Earth-Air Heat Exchangers
    Brum, R. S.
    Ramalho, J. V. A.
    Rocha, L. A. O.
    Isoldi, L. A.
    dos Santos, E. D.
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2016, 43 (5-6) : 503 - 520
  • [29] Multi-Objective Numerical Analysis of Horizontal Rectilinear Earth-Air Heat Exchangers with Elliptical Cross Section Using Constructal Design and TOPSIS
    de Andrade, Ivanilton Reinato
    dos Santos, Elizaldo Domingues
    Zhang, Houlei
    Rocha, Luiz Alberto Oliveira
    Razera, Andre Luis
    Isoldi, Liercio Andre
    FLUIDS, 2024, 9 (11)
  • [30] In Situ Testing of Earth-Air Heat Exchangers: Under Slab vs. Under Yard
    Denowh, Chantz M.
    Amende, Kevin L.
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 1, 2014, 120