An Investigation of the Wild Rat Crown Incisor as an Indicator of Lead (Pb) Exposure Using Inductively Couple Plasma Mass Spectrometry (ICP-MS) and Laser Ablation ICP-MS

被引:9
|
作者
Kataba, Andrew [1 ,2 ]
Nakayama, Shouta M. M. [1 ]
Nakata, Hokuto [1 ]
Toyomaki, Haruya [1 ]
Yohannes, Yared B. [1 ,3 ]
Yabe, John [2 ]
Muzandu, Kaampwe [2 ]
Zyambo, Golden [2 ]
Kubota, Ayano [4 ]
Matsukawa, Takehisa [4 ]
Yokoyama, Kazuhito [4 ]
Ikenaka, Yoshinori [1 ,5 ]
Ishizuka, Mayumi [1 ]
机构
[1] Hokkaido Univ, Fac Vet Med, Lab Toxicol,Dept Environm Vet Sci, Kita Ku, Kita 18 Nishi 9, Sapporo, Hokkaido 0600818, Japan
[2] Univ Zambia, Sch Vet Med, POB 32379, Lusaka 10101, Zambia
[3] Univ Gondar, Coll Nat & Computat Sci, Dept Chem, POB 196, Gondar 6200, Ethiopia
[4] Juntendo Univ, Dept Epidemiol & Environm Hlth, Fac Med, Bunkyo Ku, 2-1-1 Hongo, Tokyo 1138421, Japan
[5] North West Univ, Sch Environm Sci & Dev, Water Res Grp, Private Bag X6001, ZA-2531 Potchefstroom, South Africa
关键词
lead; incisor; biomarker; sentinel; wild rodent;
D O I
10.3390/ijerph18020767
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Lead (Pb) is a metal toxicant of great public health concern. The present study investigated the applicability of the rat incisor in Pb exposure screening. The levels of lead in teeth (Pb-T) in the crown and root of incisors in laboratory Pb-exposed Sprague Dawley rats were quantified using inductively coupled plasma mass spectrometry (ICP-MS). The crown accumulated much Pb-T than the root of the Sprague Dawley rat incisor. The levels of lead in blood (Pb-B) were positively correlated with the Pb-T in the crown and root incisors of the Sprague Dawley rats. As an application of the Pb-T crown results in experimental rats, we subsequently analyzed the Pb-T in the crown incisors of Pb-exposed wild rats (Rattus rattus) sampled from residential sites within varying distances from an abandoned lead-zinc mine. The Pb-T accumulation in the crown of incisors of R. rattus rats decreased with increased distance away from the Pb-Zn mine. Furthermore, the Pb-T was strongly correlated (r = 0.85) with the Pb levels in the blood. Laser ablation ICP-MS Pb-T mappings revealed a homogenous distribution of Pb in the incisor with an increased intensity of Pb-T localized in the tip of the incisor crown bearing an enamel surface in both Sprague Dawley and R. rattus rats. These findings suggest that Pb-T in the crown incisor may be reflective of the rat's environmental habitat, thus a possible indicator of Pb exposure.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
  • [31] Matrix interference diagnostics for the automation of inductively coupled plasma mass spectrometry (ICP-MS)
    Tromp, JW
    Tremblay, RT
    Mermet, JM
    Salin, ED
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (06) : 617 - 625
  • [32] ION KINETIC ENERGIES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS)
    FULFORD, JE
    DOUGLAS, DJ
    APPLIED SPECTROSCOPY, 1986, 40 (07) : 971 - 974
  • [33] Determination of total mercury in urine by inductively coupled plasma mass spectrometry (ICP-MS)
    Parsons, Patrick J.
    Palmer, Christopher D.
    Caldwel, Kathleen L.
    Jones, Robert L.
    PLASMA SOURCE MASS SPECTROMETRY: CURRENT TRENDS AND FUTURE DEVELOPMENTS, 2005, (301): : 59 - 71
  • [34] Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): a Personal Odyssey III
    Longerich, Henry P.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (08) : 1181 - 1184
  • [35] Quantification of Quantum Dot Concentration Using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)
    Sewell, Sarah L.
    Higgins, Melinda M.
    Bell, Charleson S.
    Giorgio, Todd D.
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2011, 7 (05) : 685 - 690
  • [36] Label-free detection of biomolecules using inductively coupled plasma mass spectrometry (ICP-MS)
    Hu, Jianyu
    Yan, Xiaowen
    Chris Le, X.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (11) : 2625 - 2640
  • [37] Label-free detection of biomolecules using inductively coupled plasma mass spectrometry (ICP-MS)
    Jianyu Hu
    Xiaowen Yan
    X. Chris Le
    Analytical and Bioanalytical Chemistry, 2024, 416 : 2625 - 2640
  • [38] Key Steps in Method Development for Inductively Coupled Plasma-Tandem Mass Spectrometry (ICP-MS/MS)
    McCurdy, Ed
    Yamanaka, Michiko
    SPECTROSCOPY, 2022, 37 (02) : 42 - 45
  • [39] Photovoltaic module characterization using laser ablation ICP-MS
    Leach, Roger
    Celikay, Recep
    Stika, Katherine
    Raty, R.
    Westphal, Craig
    Brubaker, Wayne
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [40] Preparation of hair for measurement of elements by inductively coupled plasma-mass spectrometry (ICP-MS)
    Richard F. Puchyr
    Dean A. Bass
    Rob Gajewski
    Mishelle Calvin
    William Marquardt
    Karen Urek
    Mary Ellen Druyan
    David Quig
    Biological Trace Element Research, 1998, 62 : 167 - 182