An Investigation of the Wild Rat Crown Incisor as an Indicator of Lead (Pb) Exposure Using Inductively Couple Plasma Mass Spectrometry (ICP-MS) and Laser Ablation ICP-MS

被引:9
|
作者
Kataba, Andrew [1 ,2 ]
Nakayama, Shouta M. M. [1 ]
Nakata, Hokuto [1 ]
Toyomaki, Haruya [1 ]
Yohannes, Yared B. [1 ,3 ]
Yabe, John [2 ]
Muzandu, Kaampwe [2 ]
Zyambo, Golden [2 ]
Kubota, Ayano [4 ]
Matsukawa, Takehisa [4 ]
Yokoyama, Kazuhito [4 ]
Ikenaka, Yoshinori [1 ,5 ]
Ishizuka, Mayumi [1 ]
机构
[1] Hokkaido Univ, Fac Vet Med, Lab Toxicol,Dept Environm Vet Sci, Kita Ku, Kita 18 Nishi 9, Sapporo, Hokkaido 0600818, Japan
[2] Univ Zambia, Sch Vet Med, POB 32379, Lusaka 10101, Zambia
[3] Univ Gondar, Coll Nat & Computat Sci, Dept Chem, POB 196, Gondar 6200, Ethiopia
[4] Juntendo Univ, Dept Epidemiol & Environm Hlth, Fac Med, Bunkyo Ku, 2-1-1 Hongo, Tokyo 1138421, Japan
[5] North West Univ, Sch Environm Sci & Dev, Water Res Grp, Private Bag X6001, ZA-2531 Potchefstroom, South Africa
关键词
lead; incisor; biomarker; sentinel; wild rodent;
D O I
10.3390/ijerph18020767
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Lead (Pb) is a metal toxicant of great public health concern. The present study investigated the applicability of the rat incisor in Pb exposure screening. The levels of lead in teeth (Pb-T) in the crown and root of incisors in laboratory Pb-exposed Sprague Dawley rats were quantified using inductively coupled plasma mass spectrometry (ICP-MS). The crown accumulated much Pb-T than the root of the Sprague Dawley rat incisor. The levels of lead in blood (Pb-B) were positively correlated with the Pb-T in the crown and root incisors of the Sprague Dawley rats. As an application of the Pb-T crown results in experimental rats, we subsequently analyzed the Pb-T in the crown incisors of Pb-exposed wild rats (Rattus rattus) sampled from residential sites within varying distances from an abandoned lead-zinc mine. The Pb-T accumulation in the crown of incisors of R. rattus rats decreased with increased distance away from the Pb-Zn mine. Furthermore, the Pb-T was strongly correlated (r = 0.85) with the Pb levels in the blood. Laser ablation ICP-MS Pb-T mappings revealed a homogenous distribution of Pb in the incisor with an increased intensity of Pb-T localized in the tip of the incisor crown bearing an enamel surface in both Sprague Dawley and R. rattus rats. These findings suggest that Pb-T in the crown incisor may be reflective of the rat's environmental habitat, thus a possible indicator of Pb exposure.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
  • [1] Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS for isotope analysis of long-lived radionuclides
    Becker, JS
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) : 183 - 195
  • [2] ANALYSIS OF MATERIALS BY LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS)
    ARROWSMITH, P
    ADVANCED CHARACTERIZATION TECHNIQUES CERAMICS, 1988, 5 : 87 - 101
  • [3] Analysis and comparison of glass fragments by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and ICP-MS
    Trejos, T
    Montero, S
    Almirall, JR
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (08) : 1255 - 1264
  • [4] Analysis and comparison of glass fragments by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and ICP-MS
    Tatiana Trejos
    Shirly Montero
    José R. Almirall
    Analytical and Bioanalytical Chemistry, 2003, 376 : 1255 - 1264
  • [5] Neptunium determination by inductively coupled plasma mass spectrometry (ICP-MS)
    D. E. Vance
    V. F. Belt
    T. J. Oatts
    D. K. Mann
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 234 : 143 - 147
  • [6] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    Tonouchi, S
    Habuki, H
    Katoh, K
    Yamazaki, K
    Hashimoto, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 252 (02) : 367 - 371
  • [7] INDUCTIVELY-COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS)
    DOUGLAS, DJ
    HOUK, RS
    PROGRESS IN ANALYTICAL ATOMIC SPECTROSCOPY, 1985, 8 (01): : 1 - 18
  • [8] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    S. Tonouchi
    H. Habuki
    K. Katoh
    K. Yamazaki
    T. Hashimoto
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 252 : 367 - 371
  • [9] Neptunium determination by inductively coupled plasma mass spectrometry (ICP-MS)
    Vance, DE
    Belt, VF
    Oatts, TJ
    Mann, DK
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 234 (1-2) : 143 - 146
  • [10] DETERMINATION OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS)
    LONGERICH, HP
    FRYER, BJ
    STRONG, DF
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) : 39 - 48