The third type DC flow in pulse tube cryocooler

被引:6
|
作者
Zhou Yuan [1 ]
Gu Chao [1 ,2 ]
Cai HuiKun [1 ,2 ]
机构
[1] Chinese Acad Sci, Key Lab Cryogen, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
pulse tube cryocooler; DC flow; fluid network theory; flow resistance; REFRIGERATORS;
D O I
10.1007/s11431-009-0287-x
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
New phenomena discovered in the experimental research of the ultra-high frequency pulse tube cryocooler were presented. The cause of the new phenomena was analyzed and the third type DC flow was discovered in the pulse tube cryocooler. The third type DID flow not only deteriorated cooling capacity but also led to temperature instability of the pulse tube cryocooler. From the fluid network theory and the simple regenerator model, the root of the third type DC flow was concisely investigated in theory. The asymmetric resistance of oscillating flow in pulse tube cryocooler was the key mechanism of the third type DID flow. Some suppression methods were briefly discussed.
引用
收藏
页码:3491 / 3496
页数:6
相关论文
共 50 条
  • [21] Study on the flow nonuniformity in a high capacity Stirling pulse tube cryocooler
    You, X.
    Zhi, X.
    Duan, C.
    Jiang, X.
    Qiu, L.
    Li, J.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
  • [22] Experimental study of the oscillating flow characteristics for a regenerator in a pulse tube cryocooler
    Ju, YL
    Jiang, Y
    Zhou, Y
    CRYOGENICS, 1998, 38 (06) : 649 - 656
  • [23] The Numerical Simulation and Experimental Study on a VM Type Pulse Tube Cryocooler
    Dai, Wei (cryodw@mail.ipc.ac.cn), 1600, Science Press (38):
  • [24] Recent Development Status of Stirling Type Pulse Tube Cryocooler for HTS
    Hiratsuka, Y.
    Nakano, K.
    Kato, T.
    11TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2013), PTS 1-4, 2014, 507
  • [25] Performance of a miniature pulse tube cryocooler
    Matsumoto, N.
    Yasukawa, Y.
    Ohshima, K.
    Minematsu, S.
    Takeuchi, T.
    Yoshizawa, K.
    Matsushita, T.
    Mizoguchi, Y.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 712 - +
  • [26] A pulse tube cryocooler for telecommunications applications
    Martin, JL
    Corey, JA
    Martin, CM
    CRYOCOOLERS 10, 1999, : 181 - 189
  • [27] PULSE TUBE REFRIGERATOR - AN ALTERNATIVE CRYOCOOLER
    RICHARDSON, RN
    CRYOGENICS, 1986, 26 (06) : 331 - 340
  • [28] Optimization of regenerator in high capacity Stirling type pulse tube cryocooler
    Imura, J.
    Iwata, N.
    Yamamoto, H.
    Ohashi, Y.
    Nomachi, H.
    Okumura, N.
    Nagaya, S.
    Tamada, T.
    Hirano, N.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2008, 468 (15-20): : 2178 - 2180
  • [29] Advances on a cryogen-free Vuilleumier type pulse tube cryocooler
    Wang, Yanan
    Zhao, Yuejing
    Zhang, Yibing
    Wang, Xiaotao
    Vanapalli, Srinivas
    Dai, Wei
    Li, Haibing
    Luo, Ercang
    CRYOGENICS, 2017, 82 : 62 - 67
  • [30] Development of the miniature pulse tube cryocooler
    Matsumoto, N
    Yasukawa, Y
    Ohshima, K
    Toyama, K
    Tsukahara, Y
    Kamoshita, T
    Takeuchi, T
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1339 - 1346