Multimodalities imaging for target volume definition in radiotherapy

被引:0
|
作者
Daisne, Jean-Francois
Gregoire, Vincent
机构
[1] Clin Univ St Luc, Serv Radiotherapie Oncol, B-1200 Brussels, Belgium
[2] Clin Univ St Luc, Unite Imagerie Mol & Radiotherapie Expt, B-1200 Brussels, Belgium
关键词
conformal radiotherapy; computed tomography; magnetic resonance imaging; positron emission tomography; target volume;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Modern radiotherapy delivery nowadays relies on tridimensional, conformal techniques. The aim is to better target the tumor while decreasing the dose administered to surrounding normal tissues. Gold standard imaging modality remains computed-tomography (CT) scanner. However, the intrinsic lack of contrast between soft tissues leads to high variabilities in target definition. The risks are : a geographical miss with tumor underirradiation on the one hand, and a tumor overestimation with undue normal tissues irradiation on the other hand. Alternative imaging modalities like magnetic resonance imaging and functional positron emission tomography could theoretically overcome the lack of soft tissues contrast of CT However, the fusion of the different imaging modalities images requires the use of sophisticated computer algorithms. We will briefly review them. We will then review the different clinical results reported with multi-modalities imaging for tumors of the head, neck, lung, esophagus, cervix and lymphomas, Finally, we will briefly give practical recommendations for multi-modality imaging in radiotherapy treatment planning process.
引用
收藏
页码:1175 / 1182
页数:8
相关论文
共 50 条
  • [31] Radiotherapy planning: PET/CT scanner performances in the definition of gross tumour volume and clinical target volume
    Brianzoni, E
    Rossi, G
    Ancidei, S
    Berbellini, A
    Capoccetti, F
    Cidda, C
    D'Avenia, P
    Fattori, S
    Montini, GC
    Valentini, G
    Proietti, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (12) : 1392 - 1399
  • [32] Positron emission tomography with computed tomography imaging (PET/CT) for the radiotherapy planning definition of the biological target volume: PART 1
    Alongi, Pierpaolo
    Laudicella, Riccardo
    Desideri, Isacco
    Chiaravalloti, Agostino
    Borghetti, Paolo
    Quartuccio, Natale
    Fiore, Michele
    Evangelista, Laura
    Marino, Lorenza
    Caobelli, Federico
    Tuscano, Carmelo
    Mapelli, Paola
    Lancellotta, Valentina
    Annunziata, Salvatore
    Ricci, Maria
    Ciurlia, Elisa
    Fiorentino, Alba
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2019, 140 : 74 - 79
  • [33] Positron emission tomography with computed tomography imaging (PET/CT) for the radiotherapy planning definition of the biological target volume: PART 2
    Fiorentino, Alba
    Laudicella, Riccardo
    Ciurlia, Elisa
    Annunziata, Salvatore
    Lancellotta, Valentina
    Mapelli, Paola
    Tuscano, Carmelo
    Caobelli, Federico
    Evangelista, Laura
    Marino, Lorenza
    Quartuccio, Natale
    Fiore, Michele
    Borghetti, Paolo
    Chiaravalloti, Agostino
    Ricci, Maria
    Desideri, Isacco
    Alongi, Pierpaolo
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2019, 139 : 117 - 124
  • [34] 4D imaging for target definition in stereotactic radiotherapy for lung cancer
    Slotman, Ben J.
    Lagerwaard, Frank J.
    Senan, Suresh
    ACTA ONCOLOGICA, 2006, 45 (07) : 966 - 972
  • [35] Optimization of target volume definition in stereotactic intensity-modulated radiotherapy of the pituitary gland
    Alheit, H
    Böhme, C
    Geyer, P
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 38 - 38
  • [36] PATIENT POSITIONING CONTROL VERYFICATION IN RADIOTHERAPY - THE BASIS OF MARGIN DEFINITION FOR CLINICAL TARGET VOLUME
    Kieltyka, B.
    Rawojc, K.
    Pabis, M.
    Olearski, K.
    Bochenek-Cibor, J.
    Grabowska, K.
    Kisielewicz, K.
    ACTA PHYSICA POLONICA B, 2017, 48 (10): : 1749 - 1756
  • [37] Application of gated FDG PET/CT in target volume definition for radiotherapy in esophageal cancer
    Pierre, Gustin
    Christine, Menard
    Eleonor, Rivin del Campo
    Romain, Seban
    Guillaume, Peyraga
    Olivier, Morel
    Camille, Guillerminet
    Amaury, Paumier
    ANNALS OF ONCOLOGY, 2017, 28
  • [38] FDG based hypoxic biological target volume definition for radiotherapy treatment planning of NSCLC
    Devic, S.
    Tomic, N.
    Faria, S.
    Dean, G.
    Lisbona, R.
    Podgorsak, E.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S202 - S202
  • [39] Microinvasion in hepatocellular carcinoma: predictive factor and application for definition of clinical target volume for radiotherapy
    Yan, Huamei
    Liu, Lili
    Wang, Donghui
    Xu, Jianliang
    Sun, Yaling
    Liang, Shaobo
    Huang, Yongheng
    Hao, Xinzhao
    Lin, Nan
    Xu, Xiangying
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2024, 22 (01)
  • [40] Evaluation of irregular breathing effects on internal target volume definition for lung cancer radiotherapy
    Wikstrom, Kenneth A.
    Isacsson, Ulf M.
    Pinto, Marta C.
    Nilsson, Kristina M.
    Ahnesjo, Anders
    MEDICAL PHYSICS, 2021, 48 (05) : 2136 - 2144