Biomimetic sensor chip monitoring real-time food degradation: correlating chemical deterioration with microbiological status

被引:1
|
作者
Ibrisimovic, Nadira [1 ,2 ]
Barth, Margit [1 ,2 ]
Bohrn, Ulrich [1 ,2 ]
Ibrisimovic, Mirza [1 ,2 ]
Pittner, Fritz [1 ,2 ]
机构
[1] Univ Vienna, Dept Biochem & Cell Biol, A-1030 Vienna, Austria
[2] MFPL, A-1030 Vienna, Austria
来源
MONATSHEFTE FUR CHEMIE | 2009年 / 140卷 / 08期
关键词
Biosensors; Sensors; Nanochemistry; Freshness sensor; Meat decay monitoring; Metal nanocluster sensor chip;
D O I
10.1007/s00706-009-0144-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Conventional tests currently in use for the detection and identification of food-borne pathogens and also of microbial food deterioration are time-consuming as they are based on conventional culturing techniques or monitoring environmental conditions like the increase of temperature or change in pH. These parameters do not reflect the real quality of the meat to be tested. The aim of our approach was to create a simple and cheap sensor providing reasonable sensitivity and selectivity to indicate the bacterial infection in real-time monitoring combined with a memory effect that cannot easily be corrupted. Thus, an optical thin film sensor chip was developed able to detect bacterial decay of food through a specific colour change. The design of the sensor relates to the phenomenon of "anomalous absorption'', which can best be described as a thin film enhanced absorption. A metal nanoparticle layer positioned at a well-defined distance to a smooth metal surface shows that the minimum of spectral reflectivity strongly depends on the thickness of the distance layer. This setup represents a special kind of reflection interference filter. In such a sensor setup a biomimetic polymer is integrated, which is degradable by lytic enzymes excreted by microorganisms in food decay. Meat deterioration under controlled conditions is correlated to the amount of enzymes secreted by microorganisms and the bacterial count. Thus, after incubation of the sensor setup with standard meat preparations, the enzymes released from decaying cell material change the thickness of the polymer layer and generate an easily visible colour change. This setup would be useful for integration into meat packaging.
引用
收藏
页码:941 / 945
页数:5
相关论文
共 50 条
  • [31] Chemical sensor offers sensitive real-time solution
    Hand, AJ
    PHOTONICS SPECTRA, 1999, 33 (02) : 42 - 42
  • [32] A Weak Electricigen-Based Bioelectrochemical Sensor for Real-Time Monitoring of Chemical Pollutants in Water
    Aiyer, Kartik
    Mukherjee, Debasa
    Doyle, Lucinda E.
    ACS APPLIED BIO MATERIALS, 2023, 6 (10) : 4105 - 4110
  • [33] A Chemical Approach for Real-time Monitoring Neuronal Activities
    Li, Qian
    Fan, Chunhai
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2020, 36 (04) : 729 - 730
  • [34] Real-time risk monitoring system for chemical plants
    Ky-Soo Kim
    Jae-Wook Ko
    Korean Journal of Chemical Engineering, 2005, 22 : 26 - 31
  • [35] Real-Time Water Quality Monitoring with Chemical Sensors
    Yaroshenko, Irina
    Kirsanov, Dmitry
    Marjanovic, Monika
    Lieberzeit, Peter A.
    Korostynska, Olga
    Mason, Alex
    Frau, Ilaria
    Legin, Andrey
    SENSORS, 2020, 20 (12) : 1 - 22
  • [36] Real-time monitoring and chemical profiling of a cultivation process
    Mortensen, Peter P.
    Bro, Rasmus
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2006, 84 (1-2) : 106 - 113
  • [37] Real-Time Risk Monitoring System for chemical plants
    Kim, KS
    Ko, JW
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2005, 22 (01) : 26 - 31
  • [38] A Chemical Approach for Real-time Monitoring Neuronal Activities
    Qian Li
    Chunhai Fan
    Chemical Research in Chinese Universities, 2020, 36 : 729 - 730
  • [39] Plasmoelectronic sensor for real-time on-chip wavelength selective biosensing
    Cheney, Alec
    Chen, Borui
    Zhang, Tianmu
    Thomay, Tim
    Cartwright, Alexander
    NANOSCALE IMAGING, SENSING, AND ACTUATION FOR BIOMEDICAL APPLICATIONS XIV, 2017, 10077
  • [40] The Making of "on-Chip PCR in Real-Time" for Food Quality Control
    Potrich C.
    Santini G.C.
    Lunelli L.
    Pasquardini L.
    Bertorelli R.
    de Sanctis V.
    Quattrone A.
    Pederzolli C.
    Potrich, C. (cpotrich@fbk.eu), 1600, Springer Science and Business Media, LLC (03): : 123 - 131