Seismic interaction in electrical substation equipment connected by non-linear rigid bus conductors

被引:25
|
作者
Song, Junho
Kiureghian, Armen Der [1 ]
Sackman, Jerome L.
机构
[1] Univ Calif Berkeley, Dept Civil & Environm Engn, Berkeley, CA 94720 USA
[2] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
来源
关键词
dynamic amplification; dynamic interaction; electrical equipment; electrical substation; equivalent linearization method; non-linear random vibrations; rigid bus conductors;
D O I
10.1002/eqe.620
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An important element within the power transmission lifeline is the electrical substation that typically consists of a complex set of equipment items interconnected through conductor buses or cables. If the connections are not sufficiently flexible, significant dynamic interaction may occur between the connected equipment items during a seismic event, which may result in damage and loss of the equipment. This paper investigates the interaction effect between electrical substation equipment items connected by non-linear rigid bus conductors. The equipment items are modelled as single-degree-of-freedom oscillators by use of appropriate shape functions. The hysteretic behaviours of rigid bus connectors are described by differential equation models fitted to experimental data. An efficient non-linear random vibration method is used to quantify the seismic interaction effect of the connected equipment items. Based on the developed analytical models and method, the effect of interaction in the connected equipment system is investigated through extensive parametric studies. The results lead to practical charts and guidelines for the seismic design of interconnected electrical substation equipment. Copyright (C) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:167 / 190
页数:24
相关论文
共 50 条
  • [11] Seismic performance of UHV composite post electrical equipment interconnected using a rigid bus with a sliding fitting
    He, Chang
    Zhang, Yue
    Xie, Qiang
    Yang, Zhenyu
    EARTHQUAKE SPECTRA, 2022, 38 (03) : 1705 - 1733
  • [12] Soil-Structure-Equipment Interaction and Influence Factors in an Underground Electrical Substation under Seismic Loads
    Wen, Bo
    Zhang, Lu
    Niu, Ditao
    Zhang, Muhua
    APPLIED SCIENCES-BASEL, 2017, 7 (10):
  • [13] Influence of flexible conductors on the seismic responses of interconnected electrical equipment
    Xie, Qiang
    He, Chang
    Yang, Zhenyu
    Xue, Songtao
    ENGINEERING STRUCTURES, 2019, 191 (148-161) : 148 - 161
  • [14] Seismic mitigation of substation cable connected equipment using friction pendulum systems
    Karami-Mohammadi, Reza
    Mirtaheri, Masoud
    Salkhordeh, Mojtaba
    Mosaffa, Erfan
    Mahdavi, Golsa
    Hariri-Ardebili, Mohammad Amin
    Structural Engineering and Mechanics, 2019, 72 (06): : 805 - 816
  • [15] Seismic mitigation of substation cable connected equipment using friction pendulum systems
    Karami-Mohammadi, Reza
    Mirtaheri, Masoud
    Salkhordeh, Mojtaba
    Mosaffa, Erfan
    Mahdavi, Golsa
    Hariri-Ardebili, Mohammad Amin
    STRUCTURAL ENGINEERING AND MECHANICS, 2019, 72 (06) : 785 - 796
  • [16] Seismic interaction in cable-connected equipment items
    Hong, KJ
    Kiureghian, AD
    Sackman, JL
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2001, 127 (11): : 1096 - 1105
  • [17] NON-LINEAR SEISMIC RESPONSE ANALYSIS OF SOIL STRUCTURE INTERACTION SYSTEMS
    TOKI, K
    MIURA, F
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1983, 11 (01): : 77 - 89
  • [18] ON THE EFFECTIVE SEISMIC INPUT FOR NON-LINEAR SOIL STRUCTURE INTERACTION SYSTEMS
    BIELAK, J
    CHRISTIANO, P
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1984, 12 (01): : 107 - 119
  • [19] Seismic behavior of flexible conductors connecting substation equipment - Part II: Shake table tests
    Ghalibafian, H
    Bhuyan, GS
    Ventura, C
    Rainer, JH
    Borthwick, D
    Stewart, RP
    Zhai, E
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) : 1680 - 1687
  • [20] NON-LINEAR COLLECTIVE EXCITATIONS IN SUPERIONIC CONDUCTORS
    BISHOP, AR
    JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1978, 11 (08): : L329 - L335