Eligibility for subcutaneous implantable cardioverter-defibrillator in adults with congenital heart disease

被引:13
|
作者
Zormpas, Christos [1 ,2 ]
Silber-Peest, Ann Sophie [2 ]
Eiringhaus, Jorg [1 ,2 ]
Hillmann, Henrike A. K. [1 ,2 ]
Hohmann, Stephan [1 ,2 ]
Muller-Leisse, Johanna [1 ,2 ]
Westhoff-Bleck, Mechthild [2 ]
Veltmann, Christian [1 ,2 ]
Duncker, David [1 ,2 ]
机构
[1] Hannover Med Sch, Hannover Heart Rhythm Ctr, Dept Cardiol & Angiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Hannover Med Sch, Dept Cardiol & Angiol, Hannover, Germany
来源
ESC HEART FAILURE | 2021年 / 8卷 / 02期
关键词
Subcutaneous implantable cardioverter-defibrillator; Adult congenital heart disease; S-ICD screening test; Tetralogy of Fallot; SUDDEN CARDIAC DEATH; YOUNG-ADULTS; ELECTROCARDIOGRAM; ARRHYTHMIAS; EXPERIENCE; MANAGEMENT; TETRALOGY; PACEMAKER; CHILDREN; THERAPY;
D O I
10.1002/ehf2.13243
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Patients with adult congenital heart disease (ACHD) carry an increased risk for sudden cardiac death. Implantable cardioverter-defibrillator (ICD) therapy may be challenging in these patients due to anatomical barriers, repeated cardiac surgery, or complicated transvenous access. Thus, the subcutaneous ICD (S-ICD) can be a promising alternative in this patient population. Patients with ACHD show significant electrocardiogram (ECG) abnormalities, which could affect S-ICD sensing because it depends on surface ECG. Methods and results One hundred patients with ACHD were screened for S-ICD eligibility. Standard ECG-based screening test and automated S-ICD screening test were performed in all patients. Sixty-six patients (66%) were male. Underlying congenital heart disease (CHD) was mainly CHD of great complexity (71%) and moderate complexity (29%), including repaired tetralogy of Fallot (20%), which was the most common entity. Thirty-seven patients (37%) already had a pacemaker (23%) or ICD (14%) implanted. Automated screening test identified 83 patients (83%) eligible for S-ICD implantation in either left parasternal position (78%) or right parasternal position (75%). Absence of sinus rhythm, QRS duration, and a paced QRS complex were associated with S-ICD screening failure in univariate analysis. Receiver operating characteristic curve and multivariate analysis revealed a QRS duration >= 148 ms as the only independent predictor for S-ICD screening failure. Conclusions Patients with ACHD show satisfactory eligibility rates (83%) for S-ICD implantation utilizing the automated screening test, including patients with CHD of high complexity. S-ICD therapy should be considered with caution in ACHD patients with a QRS duration >= 148 ms and/or need for ventricular pacing.
引用
收藏
页码:1502 / 1508
页数:7
相关论文
共 50 条
  • [21] The Subcutaneous Implantable Cardioverter-Defibrillator: A Patient Perspective
    Nesti, Martina
    Russo, Vincenzo
    Palama, Zefferino
    Panchetti, Luca
    Garibaldi, Silvia
    Startari, Umberto
    Mirizzi, Gianluca
    Piacenti, Marcello
    Rossi, Andrea
    Sciarra, Luigi
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (20)
  • [22] Subserratus implantation of the subcutaneous implantable cardioverter-defibrillator
    Smietana, Jeffrey
    Frankel, David S.
    Serletti, Joseph M.
    Arkles, Jeffrey
    Pothineni, Naga Venkata K.
    Marchlinski, Francis E.
    Schaller, Robert D.
    HEART RHYTHM, 2021, 18 (10) : 1799 - 1804
  • [23] Development of an Entirely Subcutaneous Implantable Cardioverter-Defibrillator
    Lupo, Pier Paolo
    Pelissero, Gabriele
    Ali, Hussam
    Sanghera, Rick
    Cappato, Riccardo
    PROGRESS IN CARDIOVASCULAR DISEASES, 2012, 54 (06) : 493 - 497
  • [24] Subcutaneous implantable cardioverter-defibrillator: Initial experience
    Galvao, Pedro
    Cavaco, Diogo
    Adragao, Pedro
    Costa, Francisco
    Carmo, Pedro
    Morgado, Francisco
    Bernardo, Ricardo
    Nunes, Manuela
    Abecasis, Miguel
    Neves, Jose
    Mendes, Miguel
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2014, 33 (09) : 511 - 517
  • [25] Subcutaneous implantable cardioverter-defibrillator: the impedance of air
    Akhtar, Zaki
    Leung, Lisa W. M.
    Gallagher, Mark M.
    Zuberi, Zia
    EUROPACE, 2022, 24 (01): : 30 - 30
  • [26] Technique for subcutaneous implantable cardioverter-defibrillator extraction
    Ip, James E.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (05) : 789 - 791
  • [27] Brugada Syndrome and the Subcutaneous Implantable Cardioverter-Defibrillator
    Nordkamp, Louise R. A. Olde
    Conte, Giulio
    Rosenmoller, Boudewijn R. A. M.
    Warnaars, Joppe L. F.
    Tan, Hanno L.
    Caputo, Maria L.
    Regoli, Francois
    Moccetti, Tiziano
    Auricchio, Angelo
    Knops, Reinoud E.
    Wilde, Arthur A. M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (06) : 665 - 666
  • [28] Evaluation of a novel automatic screening tool for determining eligibility for a subcutaneous implantable cardioverter-defibrillator
    Sakhi, Rafi
    Yap, Sing-Chien
    Michels, Michelle
    Schinkel, Arend F. L.
    Kauling, R. Martijn
    Roos-Hesselink, Jolien W.
    Theuns, Dominic A. M. J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 272 : 97 - 101
  • [29] Brugada syndrome: Eligibility for subcutaneous implantable cardioverter-defibrillator after exercise stress test
    von Hafe, Pedro
    Faria, Bebiana
    Dias, Geraldo
    Cardoso, Filipa
    Alves, Maria Jose
    Alves, Assuncao
    Rodrigues, Bernardete
    Ribeiro, Silvia
    Sanfins, Victor
    Lourenco, Antonio
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2021, 40 (01) : 33 - 38
  • [30] Subcutaneous implantable cardioverter-defibrillator in a young woman
    Calvagna, Giuseppe Mario
    Ceresa, Fabrizio
    Patane, Salvatore
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 175 (02) : E30 - E32