Dual energy X-ray absorptiometry body composition and aging in a population-based older cohort

被引:41
|
作者
Shaw, K. A.
Srikanth, V. K.
Fryer, J. L.
Blizzard, L.
Dwyer, T.
Venn, A. J.
机构
[1] Univ Tasmania, Menzies Res Inst, Hobart, Tas 7000, Australia
[2] Monash Univ, Dept Med, Monash Med Ctr, Clayton, Vic 3168, Australia
[3] Workcover New S Wales, Newcastle, NSW, Australia
[4] Murdoch Childrens Res Inst, Parkville, Vic, Australia
基金
英国医学研究理事会;
关键词
body composition; DXA; epidemiology; population based; aging;
D O I
10.1038/sj.ijo.0803417
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aims of this cross-sectional study were ( 1) to examine the effect of age on body composition in older adults using dual-energy X-ray absorptiometry (DXA) and (2) to evaluate the agreement of DXA with standard indirect anthropometric measures (body mass index (BMI), waist circumference and waist-to-hip ratio (WHR)). Research methods and procedures: A population-based sample of 731 adults aged between 50 and 79 years underwent measurement of BMI, waist circumference, WHR, DXA total body fat mass, DXA % total body fat, DXA % trunk fat and DXA lean body mass. Linear regression was used to test for trend in measures of body composition between age categories in men and women. Partial correlations and Bland-Altman analysis were used to examine the agreement of DXA measures with indirect measures. Results: DXA lean body mass decreased significantly with increasing age in both sexes (P < 0.05). In males, BMI (P=0.01) and body weight (P < 0.01) decreased with age, and in females, WHR (P=0.05), DXA % total fat (P=0.02) and DXA % trunk fat (P=0.05) increased with age. There was good agreement between DXA measures of fatness and indirect anthropometric measures, except for WHR, which showed greater variability in its comparisons with DXA. Conclusion: Using the highly sensitive and direct DXA method of measuring body composition, a decline in lean body mass and an increase in adiposity was observed with aging. Except for WHR, indirect anthropometric measures generally showed high levels of agreement with DXA fat measures in this older cohort.
引用
收藏
页码:279 / 284
页数:6
相关论文
共 50 条
  • [31] Dual-energy X-ray absorptiometry study of body composition in patients with lipodystrophy
    Valerio, Cynthia M.
    Godoy-Matos, Amelio
    Moreira, Rodrigo O.
    Carraro, Lucia
    Guedes, Erika P.
    Moises, Regina S.
    Mory, Patricia B.
    de Souza, Luciana Lopes
    Russo, Luis Augusto
    Melazzi, Ana Claudia
    DIABETES CARE, 2007, 30 (07) : 1857 - 1859
  • [32] Dual-energy X-ray absorptiometry body composition in patients with secondary osteoporosis
    Messina, Carmelo
    Monaco, Cristian Giuseppe
    Ulivieri, Fabio Massimo
    Sardanelli, Francesco
    Sconfienza, Luca Maria
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (08) : 1493 - 1498
  • [33] Body composition with dual energy X-ray absorptiometry: from basics to new tools
    Messina, Carmelo
    Albano, Domenico
    Gitto, Salvatore
    Tofanelli, Laura
    Bazzocchi, Alberto
    Ulivieri, Fabio Massimo
    Guglielmi, Giuseppe
    Sconfienza, Luca Maria
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (08) : 1687 - 1698
  • [34] Calibration of dual-energy x-ray absorptiometry estimating pig body composition
    Kipper, M.
    Marcoux, M.
    Andretta, I
    Pomar, C.
    ENERGY AND PROTEIN METABOLISM AND NUTRITION, 2019, 138 : 427 - 429
  • [35] Body composition analysis of growing pigs by dual energy X-ray absorptiometry.
    Mitchell, AD
    Scholz, AM
    FASEB JOURNAL, 1996, 10 (03): : 1203 - 1203
  • [36] Fan beam dual energy X-ray absorptiometry body composition measurements in piglets
    Chauhan, S
    Koo, WWK
    Hammami, M
    Hockman, EM
    JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2003, 22 (05) : 408 - 414
  • [37] ASSESSMENT OF WHOLE-BODY COMPOSITION WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    SLOSMAN, DO
    CASEZ, JP
    PICHARD, C
    ROCHAT, T
    FERY, F
    RIZZOLI, R
    BONJOUR, JP
    MORABIA, A
    DONATH, A
    RADIOLOGY, 1992, 185 (02) : 593 - 598
  • [38] Measurement of body composition in preterm infants by means of dual energy x-ray absorptiometry
    Hernandez Martinez, A. C.
    Escabias del Pozo, C.
    Coya Vina, J.
    Marin Ferrer, M. D.
    Couto Caro, R.
    Rodado Marina, S.
    Coronado Poggio, M.
    de Pipaon Marcos, M. Saenz
    Dorronsoro Martin, I.
    Martin Curto, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S363 - S363
  • [39] Comparison of two phantoms for body composition with dual-energy X-ray absorptiometry
    Diessel, E
    Shepherd, JA
    Fuerst, T
    Gonzalez, M
    Genant, HK
    Carew, B
    Looker, A
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 107 - 110
  • [40] Precision of the Hologic Horizon A dual energy X-ray absorptiometry in the assessment of body composition
    Cheung, Y. M.
    Roff, G.
    Grossmann, M.
    OBESITY RESEARCH & CLINICAL PRACTICE, 2020, 14 (06) : 514 - 518