Identification of Material Properties and Optimal Design of Magnetically Shielded Rooms

被引:7
|
作者
Canova, Aldo [1 ]
Freschi, Fabio [1 ]
Giaccone, Luca [1 ]
Repetto, Maurizio [1 ]
Solimene, Luigi [1 ]
机构
[1] Politecn Torino, Dipartimento Energia G Ferraris, I-10138 Turin, Italy
关键词
magnetic shielding; electromagnetic compatibility; multi-objective optimization; Rayleigh region;
D O I
10.3390/magnetochemistry7020023
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this paper, we propose an optimal design procedure for magnetically shielded rooms. Focusing on multi-layer ferromagnetic structures, where inner layers operate at very low magnetic field, we propose an identification method of the magnetic material characteristic in the Rayleigh region. A numerical model to simulate the shielding efficiency of a multi-layer ferromagnetic structure is presented and experimentally tested on different geometries and layer configurations. The fixed point iterative method is adopted to handle the nonlinearity of the magnetic material. In conclusion, the optimization of the design parameters of a MSR is discussed, using the Vector Immune System algorithm to minimize the magnetic field inside the room and the cost of the structure. The results highlight that a linear magnetic characteristic for the material is sufficient to identify the suitable geometry of the shield, but the nonlinear model in the Rayleigh region is of fundamental importance to determine a realistic shielding factor.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [41] Modeling of Leakage Magnetic Field of Electric Machines Using Blocks With Magnetizations for Design of Magnetically Shielded Room
    Muramatsu, Kazuhiro
    Gao, Yanhui
    Moriyama, Yusuke
    Dozono, Hiroshi
    Nishino, Takaaki
    Miura, Kazuyuki
    IEEE TRANSACTIONS ON MAGNETICS, 2017, 53 (06)
  • [42] Design of Bi-planar coil to suppress radial magnetic field in magnetically shielded cylinder for magnetocardiography
    Xie, Xiaoxuan
    Zhou, Xiangyang
    Zhao, Fengwen
    Wang, Weiqian
    Yin, Chuanming
    Sun, Jinji
    PHYSICA SCRIPTA, 2024, 99 (10)
  • [43] Design and Test of a Magnetic-Field Compensation Coil Without Interference With the Door of a Magnetically Shielded Room
    Liu, Xikai
    Wu, Chen
    Zhang, Lu
    Wen, Tong
    Zheng, Shiqiang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [44] Method for Evaluating Shielding Factor of Double Layered Magnetically-Shielded Rooms for Uniform Magnetic Field Using Exciting Coils Placed on One Side
    Odawara, Shunya
    Muramatsu, Kazuhiro
    Komori, Shogo
    Kamata, Kiyotaka
    Yamazaki, Keita
    Yamaguchi, Takao
    Sakakibara, Mitsuru
    Shinnoh, Toshifumi
    Simokawa, Masao
    Ishikawa, Noboru
    Meguro, Takashi
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (06) : 2357 - 2360
  • [45] Optimal design by means of material derivative
    Krawczyk, A
    Kwiatkowska, A
    Sikora, J
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 1998, 17 (1-3) : 155 - 159
  • [46] Optimal design by means of material derivative
    Krawczyk, Andrzej
    Kwiatkowska, Anna
    Sikora, Jan
    COMPEL - The International Journal for Computation and Mathematics in Electrical and Electronic Engineering, 1998, 17 (01): : 155 - 159
  • [47] Method for evaluating shielding factor of double layered magnetically-shielded rooms for uniform magnetic field using exciting coils placed on one side
    Department of Electrical and Electronic Engineering, Saga Univ., Saga 840-8502, Japan
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    IEEE Trans Magn, 6 (2357-2360):
  • [48] Optimal Design of Material Carrying Mechanism
    Lv, Chuanyi
    Bai, Xue
    Yang, Xianhai
    PROCEEDINGS OF 2009 INTERNATIONAL CONFERENCE ON INFORMATION, ELECTRONIC AND COMPUTER SCIENCE, VOLS I AND II, 2009, : 253 - 256
  • [49] Optimal Design of Self-Shielded Biplanar Coil Assembly With Miniaturized Structure
    Tang, Shuo
    Lu, Jixi
    Sun, Bowen
    Wang, Shuying
    Wang, Kun
    Zhang, Xu
    Li, Bo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [50] OPTIMAL-DESIGN OF A SELF SHIELDED MAGNETIC-RESONANCE-IMAGING MAGNET
    SOUZA, M
    VIDIGAL, C
    TAQUIN, J
    SAUZADE, M
    JOURNAL DE PHYSIQUE III, 1993, 3 (11): : 2121 - 2132