Identification of Material Properties and Optimal Design of Magnetically Shielded Rooms

被引:7
|
作者
Canova, Aldo [1 ]
Freschi, Fabio [1 ]
Giaccone, Luca [1 ]
Repetto, Maurizio [1 ]
Solimene, Luigi [1 ]
机构
[1] Politecn Torino, Dipartimento Energia G Ferraris, I-10138 Turin, Italy
关键词
magnetic shielding; electromagnetic compatibility; multi-objective optimization; Rayleigh region;
D O I
10.3390/magnetochemistry7020023
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this paper, we propose an optimal design procedure for magnetically shielded rooms. Focusing on multi-layer ferromagnetic structures, where inner layers operate at very low magnetic field, we propose an identification method of the magnetic material characteristic in the Rayleigh region. A numerical model to simulate the shielding efficiency of a multi-layer ferromagnetic structure is presented and experimentally tested on different geometries and layer configurations. The fixed point iterative method is adopted to handle the nonlinearity of the magnetic material. In conclusion, the optimization of the design parameters of a MSR is discussed, using the Vector Immune System algorithm to minimize the magnetic field inside the room and the cost of the structure. The results highlight that a linear magnetic characteristic for the material is sufficient to identify the suitable geometry of the shield, but the nonlinear model in the Rayleigh region is of fundamental importance to determine a realistic shielding factor.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [1] Demagnetization of magnetically shielded rooms
    Thiel, F.
    Schnabel, A.
    Knappe-Grueneberg, S.
    Stollfuss, D.
    Burghoff, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (03):
  • [2] Numerical Modeling and Material Characterization for Multilayer Magnetically Shielded Room Design
    Canova, A.
    Freschi, F.
    Giaccone, L.
    Repetto, M.
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (03)
  • [3] Optimal Inverse Design of Magnetic Field Profiles in a Magnetically Shielded Cylinder
    Packer, M.
    Hobson, P. J.
    Holmes, N.
    Leggett, J.
    Glover, P.
    Brookes, M. J.
    Bowtell, R.
    Fromhold, T. M.
    PHYSICAL REVIEW APPLIED, 2020, 14 (05):
  • [4] NEW RESULTS IN ACTIVE NOISE COMPENSATION FOR MAGNETICALLY SHIELDED ROOMS
    TERBRAKE, HJM
    HUONKER, R
    ROGALLA, H
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1993, 4 (12) : 1370 - 1375
  • [5] Incremental permeability of Mu-metal in low fields for the design of multilayer-type magnetically shielded rooms
    Yamazaki, K
    Kato, K
    Muramatsu, K
    Haga, A
    Kobayashi, K
    Kamata, K
    Fujiwara, K
    Yamaguchi, T
    IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (10) : 4087 - 4089
  • [6] Low cost shielded rooms; From material to practical realisations
    Hebert, L
    De Schacht, J
    ELECTROMAGNETIC COMPATIBILITY 1998, 1998, : 419 - 422
  • [8] FEA simulations for low-frequency multi-layer magnetically shielded rooms
    Yang, Songnan
    Zhang, Xiaohui
    Gao, Jiuxiang
    Liu, Yuanyuan
    Zhang, Jinsheng
    Xi, Xiaoli
    AIP ADVANCES, 2022, 12 (08)
  • [9] Optimal structure of magnetic and conductive layers of a magnetically shielded room
    Yamazaki, Keita
    Muramatsu, Kazuhiro
    Hirayama, Masayuki
    Haga, Akira
    Torita, Fumihiko
    IEEE TRANSACTIONS ON MAGNETICS, 2006, 42 (10) : 3524 - 3526
  • [10] Evaluation of Conduction Property to Improve Performance of Conductive Shield Layer Installed in Magnetically Shielded Rooms
    Odawara, Shunya
    Sakakibara, Mitsuru
    Yoshimura, Keisuke
    Gotoh, Yuji
    2023 IEEE INTERNATIONAL MAGNETIC CONFERENCE, INTERMAG, 2023,