DEVELOPMENT OF R290 TRANSPORT REFRIGERATION SYSTEM

被引:10
|
作者
Colbourne, D. [1 ]
Solomon, P. [2 ]
Wilson, R. [2 ]
de Swardt, L. [2 ]
Schuster, M. [1 ]
Oppelt, D. [1 ]
Gloel, J. [1 ]
机构
[1] GIZ Proklima, Dag Hammarskjold Weg 1-5, D-65760 Eschborn, Germany
[2] Transfrig SA Pty Ltd, POB 1365, ZA-2054 Kelvin, Sandton, South Africa
关键词
hydrocarbon refrigerant; R290; transport refrigeration; safety; risk mitigation;
D O I
10.18462/iir.gl.2016.1002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Transport refrigeration systems for small and large trucks have been developed using R290. They are electrically driven via a diesel engine and alternator and include a variable speed drive for capacity control. For the design of the systems the main aspects addressed were circuit optimisation and integration of safety measures. Circuit optimisation comprised system simulations in order to select compressors and redesign of heat exchangers in order to achieve the same cooling capacities as R404A, whilst maximising improvement in COP and reducing refrigerant charge as much as possible. Subsequent to this, measurements were carried out to validate the performance with R290. In order to mitigate the flammability risk of using R290, several aspects were addressed. In terms of the equipment redesign, other than charge size reduction, the main changes were to remove potential sources of ignition or apply pre-ventilation to remove any build-up of potentially flammable mixtures. Additionally, a leak identification feature was integrated into the system controls whereby a suspected substantial leak would result in a shut-down of the system and a warning signal to ensure no additional refrigerant can leak into the refrigerated space. Extensive leak simulation tests were carried out to characterise the development of potentially flammable concentrations around the condensing unit and surrounding area, within the refrigerated and adjacent spaces. Conformity to the relevant parts of EN 378 and the essential health and safety requirements of the Atex (equipment) directive were confirmed.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 50 条
  • [21] Refrigeration system development with limited charge of flammable Refrigerant, R-290
    Jones, Alan
    Wolf, Arne
    Kwark, Sang Muk
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 34
  • [22] Thermodynamic comparison of various refrigerants for an on-board R290 refrigeration system with economizer subcooling in small fishing boats
    Singha, Prosenjit
    Das, Chayan
    Koster, Lukas
    Kochunni, Sarun Kumar
    Dasgupta, Mani Sankar
    Widell, Kristina Norne
    Bhattacharyya, Souvik
    Hafner, Armin
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 60
  • [23] Investigation of R290/R170 substituting R22/R23 in cascade refrigeration cycle
    Xie, Y. B.
    Liu, Ch T.
    Lun, L. Y.
    Zhang, X. D.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 509 - 513
  • [24] Experimental analysis on R290 solubility and R290/oil mixture viscosity in oil sump of the rotary compressor
    Wu, Jianhua
    Chen, Zhenhua
    Lin, Jie
    Li, Jinbo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 94 : 24 - 32
  • [25] Thermodynamic analysis and performance optimization on an ultra-low-temperature cascade refrigeration system using refrigerants R290 and R170
    Ji, Shenrui
    Liu, Zhan
    Li, Jiafeng
    Wang, Tao
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2024,
  • [26] Conventional and advanced exergy analysis of parallel and series compression-ejection hybrid refrigeration system for a household refrigerator with R290
    Zhao, Hongxia
    Yuan, Tianpeng
    Gao, Jia
    Wang, Xinli
    Yan, Jia
    ENERGY, 2019, 166 : 845 - 861
  • [27] THE PERFORMANCE EVALUATION OF R744 TRANSCRITICAL EJECTOR AND R290/R744 CASCADE REFRIGERATION SYSTEMS FOR TURKEY
    Yilmaz, Deniz
    Yilmaz, Baris
    Mancuhan, Ebru
    THERMAL SCIENCE, 2019, 23 (06): : 4031 - 4041
  • [28] Performance analysis of an ejector enhanced refrigeration cycle with R290/R600a for application in domestic refrigerator/freezers
    Chen, Qi
    Yan, Gang
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2017, 120 : 581 - 592
  • [29] Performance evaluation on an internal auto-cascade refrigeration cycle with mixture refrigerant R290/R600a
    Yan, Gang
    Hu, Hui
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2015, 75 : 994 - 1000
  • [30] Thermodynamic analysis on a modified ejector expansion refrigeration cycle with zeotropic mixture (R290/R600a) for freezers
    Yan, Gang
    Bai, Tao
    Yu, Jianlin
    ENERGY, 2016, 95 : 144 - 154