On the stability of the zinc x-ray laser beam quality using a half cavity

被引:0
|
作者
Präg, AR [1 ]
Mocek, T [1 ]
Kozlová, M [1 ]
Rus, B [1 ]
机构
[1] Acad Sci Czech Republ, Inst Phys, Prague 18221 8, Czech Republic
来源
X-RAY LASERS 2002 | 2002年 / 641卷
关键词
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
At the Prague Asterix Laser System Center (PALS) the Asterix laser delivering up to 700 J in 0.5 ns is used as a pump source for x-ray laser experiments and applications. The prepulse technique was applied which is known to improve the neon-like x-ray laser at the J = 0-1 transition dramatically. Since Zri slab targets were used the output wavelength was 21.2 nm. A prepulse having up to 20 J precedes the main pulse by 10 ns. The main beam and the prepulse beam are focussed by two different optical systems separately and their foci are superimposed at the target surface. By implementing a half-cavity for double-pass amplification using a Mo/Si multilayer mirror - which can be used for 100 shots - the x-ray laser output was more than 10 times stronger than at the single pass in a 3 cm long plasma. Double-pass amplification was observed to be most efficient when the pump pulse was at least 150 ps longer than the round trip time (approximate to 260 ps) in the half-cavity. Under this fundamental condition the x-ray laser reached saturation in the double-pass regime containing similar to4mJ energy which was proved to be enough for applications. In this contribution, the x-ray laser features like divergence in two dimensions, the beam quality (symmetry), and the pointing angle are investigated over 110 shots. To characterize the stability of the x-ray laser the shot distribution, the mean value and the standard deviation for these parameters are evaluated. For 18 shots of a one-day-series these values are given, and a statistical analysis carrying out a chi-squared test characterize the Zn x-ray laser as a robust tool suitable for future applications.
引用
收藏
页码:174 / 181
页数:8
相关论文
共 50 条
  • [21] X-ray optics for the cavity-based X-ray free-electron laser
    Liu, Peifan
    Pradhan, Paresh
    Shi, Xianbo
    Shu, Deming
    Kauchha, Keshab
    Qiao, Zhi
    Tamasaku, Kenji
    Osaka, Taito
    Zhu, Diling
    Sato, Takahiro
    MacArthur, James
    Huang, XianRong
    Assoufid, Lahsen
    White, Marion
    Kim, Kwang-Je
    Shvyd'ko, Yuri
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 : 751 - 762
  • [22] Long-term stability of beam quality and output of conventional X-ray units
    Fukuda A.
    Matsubara K.
    Miyati T.
    Radiological Physics and Technology, 2015, 8 (1) : 26 - 29
  • [23] Cavity based x-ray free electron laser demonstrator at the European X-ray Free Electron Laser facility
    Rauer, Patrick
    Decking, Winfried
    Lipka, Dirk
    Thoden, Daniel
    Wohlenberg, Torsten
    Bahns, Immo
    Brueggmann, Ulf
    Casalbuoni, Sara
    Di Felice, Massimiliano
    Dommach, Martin
    Gruenert, Jan
    Karabekyan, Suren
    Koch, Andreas
    La Civita, Daniele
    Rio, Benoit
    Samoylova, Liubov
    Sinn, Harald
    Vannoni, Maurizio
    Youngman, Christopher
    Hillert, Wolfgang
    Rossbach, Joerg
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2023, 26 (02)
  • [24] Quality assessment of sapphire wafers for X-ray crystal optics using white beam Synchrotron X-Ray Topography
    Chen, WM
    McNally, PJ
    Shvydko, YV
    Tuomi, T
    Lerche, M
    Danilewsky, AN
    Kanatharana, J
    Lowney, D
    O'Hare, M
    Knuuttila, L
    Riikonen, J
    Rantamäki, R
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2001, 186 (03): : 365 - 371
  • [25] Effect of Optics Contamination on X-ray Free-Electron Laser Beam Quality
    Tong Yajun
    Liu Fang
    Fan Jiadong
    Jin Limin
    Dong Xiaohao
    Yu Xiaojiang
    Jiang Huaidong
    Liu Zhi
    ACTA OPTICA SINICA, 2022, 42 (11)
  • [26] X-ray tube stability and beam integrity characterization
    Pantazis, TJ
    SPECTROSCOPY, 2004, : 11 - 11
  • [27] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [28] X-ray diagnostics for the cavity-based x-ray free-electron laser project
    Liu, Peifan
    Pradhan, Paresh
    Miceli, Antonino
    Walko, Donald A.
    Shu, Deming
    Sullivan, Joseph
    Lang, Keenan
    Rivers, Mark
    Balcazar, Mario
    Li, Kenan
    Margraf, Rachel
    Halavanau, Aliaksei
    Sakdinawat, Anne
    Sato, Takahiro
    Zhu, Diling
    Ko, Yuri Shvyd '
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2024, 27 (11)
  • [29] Operando X-Ray Tomoscopy of Laser Beam Welding
    Kamm, Paul Hans
    Boerner, Stephan
    Neu, Tillmann Robert
    Schlepuetz, Christian Matthias
    Dittrich, Dirk
    Banhart, John
    Garcia-Moreno, Francisco
    ADVANCED SCIENCE, 2025, 12 (09)
  • [30] A saturated X-ray laser beam at 7 nanometers
    Zhang, J
    MacPhee, AG
    Lin, J
    Wolfrum, E
    Smith, R
    Danson, C
    Key, MH
    Lewis, CLS
    Neely, D
    Nilsen, J
    Pert, GJ
    Tallents, GJ
    Wark, JS
    SCIENCE, 1997, 276 (5315) : 1097 - 1100