Quantification of palm oil bioactive compounds by ultra-high-performance supercritical fluid chromatography and chemometrics

被引:4
|
作者
de Souza Guedes, Luciana [1 ]
Santana, Cesar Costapinto [1 ]
Rutledge, Douglas Neil [2 ,3 ]
Pinto, Licarion [4 ]
Jardim, Isabel Cristina Sales Fontes [5 ]
de Melo, Lucilia Vilela [5 ]
Beppu, Marisa Masumi [1 ]
Breitkreitz, Marcia Cristina [5 ]
机构
[1] Univ Estadual Campinas, Sch Chem Engn, Ave Albert Einstein 500, BR-13083852 Campinas, SP, Brazil
[2] Univ Paris Saclay, INRAE, AgroParisTech, UMR SayFood, Paris, France
[3] Charles Sturt Univ, Natl Wine & Grape Ind Ctr, Wagga Wagga, NSW, Australia
[4] Univ Fed Pernambuco, Dept Fundamental Chem, Recife, PE, Brazil
[5] Univ Estadual Campinas, Inst Chem, Campinas, Brazil
来源
关键词
carotenoids; coenzyme Q10; MCR‐ ALS; palm oil; UHPSFC; MULTIVARIATE CURVE RESOLUTION; QUANTITATIVE-ANALYSIS; MINOR COMPONENTS; MCR-ALS; CAROTENOIDS; LIQUID; HPLC; CALIBRATION; EXTRACTION; IDENTIFICATION;
D O I
10.1002/cjce.23969
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Lycopene, beta-carotene, coenzyme Q10, and lutein are minor constituents of palm oil that are removed during biodiesel production to produce light-coloured oils. With the aim to investigate the recovery of these valuable compounds, a separation method was developed to quantify carotenoids and coenzyme Q10 in palm oil by ultra-high-performance supercritical fluid chromatography. Due to the presence of interferents, different clean-up procedures were evaluated; however, these approaches were ineffective and the separation method was developed without this step. The chemometric method multivariate curve resolution-alternating least squares was employed to properly quantify lycopene, beta-carotene, and coenzyme Q10 in the presence of interferents. Lutein was sufficiently resolved to be quantified by a univariate method. Lycopene concentration was below the limit of quantification 3.12 mu g/mL (3.12 x 10(-3) kg/m(3)). Beta-carotene concentration was determined as being 183.48 +/- 1.66 mu g/mL (183.48 +/- 1.66 x 10(-3) kg/m(3)). Coenzyme Q10 concentration was lower than the limit of detection 4.22 mu g/mL (4.22 x 10(-3) kg/m(3)) and lutein concentration 9.24 mu g/mL (9.24 x 10(-3) kg/m(3)) was below the limit of quantification. The study showed the analytical challenges associated with the separation and quantification of minor constituents of a highly complex matrix such as palm oil and demonstrated that the recovery of beta-carotene could be economically viable due to its wide range of application in industry.
引用
收藏
页码:S629 / S644
页数:16
相关论文
共 50 条
  • [41] Chemical Fingerprinting and Quantification of Chinese Cinnamomi Cortex by Ultra High Performance Liquid Chromatography Coupled with Chemometrics Methods
    Ma, Ninghui
    Ding, Yue
    Zhang, Yong
    Zhang, Tong
    Yi, Yaxiong
    Wang, Bing
    MOLECULES, 2018, 23 (09):
  • [42] Identification of chemical constituents in pomegranate seeds based on ultra-high-performance supercritical fluid chromatography coupled with quadrupole time-of-flight mass spectrometry
    Li, Guoping
    Chen, Jing
    Yang, Qing
    Yang, Xuexin
    Wang, Penglong
    Lei, Haimin
    Mi, Ma
    Ma, Qiang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (S1)
  • [43] Controlling the positive ion electrospray ionization of poly(ethylene glycols) when using ultra-high-performance supercritical fluid chromatography-mass spectrometry
    Cancho-Gonzalez, Sergio
    Ferguson, Paul
    Herniman, Julie M.
    Langley, G. John
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (20)
  • [44] Ultra-high performance supercritical fluid chromatography coupled with quadrupole-time-of-flight mass spectrometry as a performing tool for bioactive analysis
    Perrenoud, Alexandre Grand-Guillaume
    Guillarme, Davy
    Boccard, Julien
    Veuthey, Jean-Luc
    Barron, Denis
    Moco, Sofia
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1450 : 101 - 111
  • [45] Application of ultra-high performance supercritical fluid chromatography for the determination of carotenoids in dietary supplements
    Li, Bing
    Zhao, Haiyan
    Liu, Jing
    Liu, Wei
    Fan, Sai
    Wu, Guohua
    Zhao, Rong
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1425 : 287 - 292
  • [46] Ultra-high performance supercritical fluid chromatography in impurity control II: Method validation
    Plachka, Katerina
    Khalikova, Maria
    Babicova, Barbora
    Nemcova, Zdenka
    Roubickova, Lucie
    Svec, Frantisek
    Novakova, Lucie
    ANALYTICA CHIMICA ACTA, 2020, 1117 : 48 - 59
  • [47] The Effect of Pressure and Solvent on the Supercritical Fluid Chromatography Separation of Tocol Analogs in Palm Oil
    Ng, Mei Han
    Kushairi, Ahmad
    MOLECULES, 2017, 22 (09):
  • [48] ENHANCING THE SEPARATION AND PURIFICATION EFFICIENCY OF PALM OIL CAROTENES USING SUPERCRITICAL FLUID CHROMATOGRAPHY
    Han, Ng Mei
    Choo, Y. M.
    JOURNAL OF OIL PALM RESEARCH, 2015, 27 (04): : 387 - 392
  • [49] Development and validation of ultra-high performance supercritical fluid chromatography method for determination of illegal dyes and comparison to ultra-high performance liquid chromatography method
    Khalikova, Maria A.
    Satinsky, Dalibor
    Solich, Petr
    Novakova, Lucie
    ANALYTICA CHIMICA ACTA, 2015, 874 : 84 - 96
  • [50] Determination of Urolithin A in Health Products by Ultra-High-Performance Liquid Chromatography
    E, Yue
    Wang, Zhuang
    Nie, Jiahui
    MOLECULES, 2025, 30 (05):