Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function

被引:23
|
作者
Wintersperger, Bernd J. [1 ]
Sincleair, Spencer
Runge, Val M.
Dietrich, Olaf
Huber, Armin
Reiser, Maximilian F.
Schoenberg, Stefan O.
机构
[1] Univ Munich, Univ Hosp Grosshadern, Dept Clin Radiol, Munich, Germany
[2] Texas A&M Univ, Hlth Sci Ctr, Scott & White Clin & Hosp, Dept Radiol, Temple, TX USA
关键词
heart; volume; magnetic resonance (MR); cine study; volume measurement; parallel imaging;
D O I
10.1007/s00330-006-0259-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of our study was to evaluate the accuracy of a multislice cine magnetic resonance imaging (MRI) technique with parallel imaging in regard to global and regional left ventricular function. Forty-two individuals underwent cine MRI on a 1.5-tesla scanner. Cine MRI used a steady-state free precession technique and was performed as a single-slice technique (nonTSENSE cine) and an accelerated multislice technique (TSENSE cine) with five slices per breath-hold. End diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) were evaluated for all data sets and in regard to regional wall motion and regional wall motion analysis, and quantitative regional wall thickness and systolic thickening were also assessed. EDV, ESV, and EF based on TSENSE cine showed excellent correlation to the nonTSENSE cine approach ( all r(2)= 0.99, P< 0.001). While EDV evaluations showed a small underestimation for TSENSE cine, ESV and EF showed accurate results compared with nonTSENSE cine. Both readers showed good agreement (kappa= 0.72) in regional wall motion assessment comparing both techniques. Data acquisition for the multislice approach was significantly shorter (similar to 75%) that in single-slice cine. We conclude that accurate evaluation of regional wall motion and left ventricular EF is possible using accelerated multislice cine MR with high spatial and temporal resolution.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 50 条
  • [21] Artifact-free black-blood cine cardiac imaging in a single breath-hold
    Fahmy, Ahmed S.
    Pan, Li
    Osman, Nael F.
    MAGNETIC RESONANCE IMAGING, 2006, 24 (10) : 1303 - 1310
  • [22] T2 weighted liver Magnetic Resonance imaging using functional residual capacity breath-hold with multi breath-hold
    Tabuchi, A.
    Katsuda, T.
    Gotanda, R.
    Gotanda, T.
    Yamamoto, K.
    Mitani, M.
    Takeda, Y.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1598 - 1602
  • [23] Cardiac function during breath-hold diving in humans: An echocardiographic study
    Marabotti, C.
    Belardinelli, A.
    L'abbate, A.
    Scalzini, A.
    Chiesa, F.
    Cialoni, D.
    Passera, M.
    Bedini, R.
    UNDERSEA & HYPERBARIC MEDICINE, 2008, 35 (02): : 83 - 90
  • [24] Effect of variable breath-hold positions during cardiac magnetic resonance on measures of left ventricular mechanics
    Sean M Hamlet
    Gregory J Wehner
    Jonathan D Suever
    David Powell
    Christopher M Haggerty
    Linyuan Jing
    Xiaodong Zhong
    Frederick H Epstein
    Brandon K Fornwalt
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [25] Single-Breath-Hold Evaluation of Cardiac Function with Use of Time-Resolved Parallel Cardiac Magnetic Resonance
    Krumm, Patrick
    Keuler, Jonas D.
    Mangold, Stefanie
    Zitzelsberger, Tanja
    Ruff, Christer A.
    Klumpp, Bernhard D.
    Martirosian, Petros
    Nikolaou, Konstantin
    Burgstahler, Christof
    Kramer, Ulrich
    TEXAS HEART INSTITUTE JOURNAL, 2017, 44 (04): : 252 - 259
  • [26] Quantitative evaluation of ventricular function with velocity mapping and breath-hold cine MRI in patients with redo surgery for tetralogy of fallot
    Dymarkowski, S
    Eyskens, B
    Gewillig, M
    Bogaert, JG
    RADIOLOGY, 1998, 209P : 262 - 262
  • [27] Global cardiac function using fast breath-hold MRI: Validation of new acquisition and analysis techniques
    Bloomgarden, DC
    Fayad, ZA
    Ferrari, VA
    Chin, B
    Sutton, MGSJ
    Axel, L
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) : 683 - 692
  • [28] A single breath-hold for analysis of systolic and diastolic cardiac function: TGRAPPA accelerated multiplanar Cine MR imaging at 3 Tesla
    Torleif A Sandner
    Daniel Theisen
    Kerstin U Bauner
    Konstantin Nikolaou
    Maximilian F Reiser
    Bernd J Wintersperger
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [29] EVALUATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH BREATH-HOLD CINE MR-IMAGING
    SAKUMA, H
    FUJITA, N
    FOO, TKF
    CAPUTO, GR
    NELSON, SJ
    HARTIALA, J
    SHIMAKAWA, A
    HIGGINS, CB
    RADIOLOGY, 1993, 188 (02) : 377 - 380
  • [30] EVALUATION OF CARDIAC MOTION AND FUNCTION BY CINE MAGNETIC-RESONANCE-IMAGING
    KONDO, T
    KUROKAWA, H
    ANNO, H
    OKAMURA, M
    ANNO, N
    SAKAKURA, K
    TOKUDA, M
    HISHIDA, H
    WATANABE, Y
    MIZUNO, Y
    SUGIISHI, M
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1992, 56 (06): : 632 - 638