Integration of BIM and Archibus for Facility Management (FM) in FKAAS, UTHM Building

被引:3
|
作者
Solla, M. [1 ,2 ]
Shaarani, A. S. M. [2 ]
Mustaffa, A. A. [3 ]
Ismail, L. H. [1 ]
机构
[1] Univ Tun Hussein Onn Malaysia, Fac Civil & Environm Engn, Dept Construct Engn & Architecture, Batu Pahat 86400, Johor, Malaysia
[2] Microcorp Sdn Bhd, Seri Kembangan 43300, Selangor, Malaysia
[3] Univ Tun Hussein Onn Malaysia, Fac Civil & Environm Engn, Dept Civil Engn, Batu Pahat 86400, Johor, Malaysia
关键词
D O I
10.1088/1755-1315/498/1/012088
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Building Information Modelling (BIM) can play a great role in improving the operation and maintenance (O&M) of building and facility management (FM) through the use of construction technology. BIM can be implemented in design, construction and facility management which provide a digital database of information management that can be easily shared between stakeholders. However, the use of BIM in O&M for FM is still limited in Malaysian construction. The aim of this study is to explore the integration of using BIM tools and FM software for space management as the primary key to facility management. FKAAS building located in UTHM has been used as the case study for this research. The main objective is to develop a 3D BIM model by using Revit Autodesk and integrate into ARCHIBUS software to manage spaces based on Sistem Kod Aset Tak Alih Kerajaan (SKATA). As a result, the data of the building can be used by the facility management to manage the building spaces in a more efficient way and enhance the building performance in future. This result can help the facility management of FKAAS building to manage spaces, space inventory and better performance and maintenance for FKAAS and other UTHM Buildings.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] BIM for CREM: Exploring the Benefit of Building Information Modelling for Facility Management in Corporate Real Estate Management
    Benn, Maximilian
    Stoy, Christian
    BUILDINGS, 2022, 12 (04)
  • [32] BIM Enabled Sustainable Facility Management
    Rahman, Md Motiar
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2021, 13 (07): : 101 - 107
  • [33] BIM Facility Management on Utility tunnel
    Szu-Min Kang
    Yayu Tseng
    and Richard Moh
    办公自动化, 2014, (S1) : 174 - 177
  • [34] A study on software architecture for effective BIM/GIS-based facility management data integration
    Kang, Tae Wook
    Hong, Chang Hee
    AUTOMATION IN CONSTRUCTION, 2015, 54 : 25 - 38
  • [35] Developing a Web-Based BIM Asset and Facility Management System of Building Digital Twins
    Yan, Jiayi
    Yin, Kai
    Lu, Qiuchen
    Shen, Xu
    COMPUTING IN CIVIL ENGINEERING 2021, 2022, : 490 - 497
  • [36] Integrated information management for the FM: Building information modelling and database integration for the Italian Public Administration
    Pinti, L.
    Bonelli, S.
    Brizzolari, A.
    Mirarchi, C.
    Dejaco, M. C.
    Kiviniemi, A.
    EWORK AND EBUSINESS IN ARCHITECTURE, ENGINEERING AND CONSTRUCTION, 2018, : 21 - 28
  • [37] Information Integration for Facility Management
    D'Urso, Ciro
    IT PROFESSIONAL, 2011, 13 (06) : 48 - 53
  • [38] Digital Management of Large Building Stocks: BIM and GIS Integration-Based Systems
    Mangia, Mattia
    Lazoi, Mariangela
    Mangialardi, Giovanna
    PRODUCT LIFECYCLE MANAGEMENT: GREEN AND BLUE TECHNOLOGIES TO SUPPORT SMART AND SUSTAINABLE ORGANIZATIONS, PT I, 2022, 639 : 133 - 150
  • [39] INTEGRATION OF REAL-TIME DATA IN BIM ENABLES FM PROCESSES
    Wills, Nadine
    Diaz, Joaquin
    BUILDING INFORMATION MODELLING (BIM) IN DESIGN, CONSTRUCTION AND OPERATIONS II, 2017, 169 : 127 - 133
  • [40] BIM and facility management in the chemical and pharmaceutical industry
    Meinen, H.
    Kock, K.
    Huebner, R.
    BAUINGENIEUR, 2024, 99 (05): : 165 - 171