A model-based algorithm to correct for the loss of backscatter in superficial X-ray radiation therapy

被引:2
|
作者
Harwood, Jeffrey R. [1 ]
Nelli, Flavio E. [1 ]
机构
[1] Univ Hosp Geelong, Andrew Love Canc Ctr, 70 Swanston St, Geelong, Vic 3220, Australia
关键词
Backscatter; Superficial X-ray therapy; Gafchromic film; Monte Carlo; DOSE REDUCTION; MM AL; RADIOTHERAPY; DOSIMETRY;
D O I
10.1016/j.ejmp.2019.08.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dosimetry protocols for superficial X-rays prescribe the determination of kerma on the surface of a phantom through the use of a backscatter factor (B-w) that accounts for the effect of phantom scatter. B-w values corresponding to full-scatter phantoms are provided by these protocols. In practice, clinical situations arise wherein there is insufficient scattering material downstream, resulting in published B-w values that overestimate the amount of occurring scatter. To provide an accurate dose calculation the backscatter values need to be corrected for any reduction in scattered radiation. Estimating the change of B-w in situations with incomplete backscatter has previously been achieved by direct measurements or Monte Carlo modelling. For increasing the accuracy of clinical dosimetries, we developed a physical model to deduce an algorithm for calculating backscatter factors in situations with reduced downstream scattering medium. The predictions of the model were validated by comparison with published data, Monte Carlo simulations and film-based measurements for beams with a half-value layer of 0.8, 2 and 4 mm Al. Our algorithm accurately predicts the effect of partial scatter conditions with suitable precision. Its reliability, combined with the simplicity of calculation, makes this methodology suitable to be incorporated into routine clinical dosimetry. The algorithm's underlying physical model provides an intuitive understanding of the effects of field size and beam energy on backscatter reduction, permitting a rational management of this effect.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [21] Model-based segmentation of reconstructed dental X-ray volumes
    Antila, Kari
    Lilja, Mikko
    Kalke, Martti
    Lotjonen, Jyrki
    2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 1933 - +
  • [22] Model-based sphere localization (MBSL) in x-ray projections
    Sawall, Stefan
    Maier, Joscha
    Leinweber, Carsten
    Funck, Carsten
    Kuntz, Jan
    Kachelriess, Marc
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (16): : 6486 - 6496
  • [23] SUPERFICIAL X-RAY THERAPY IN THE TREATMENT OF PALMOPLANTAR PUSTULOSIS
    FAIRRIS, GM
    JONES, DH
    MACK, DP
    ROWELL, NR
    BRITISH JOURNAL OF DERMATOLOGY, 1984, 111 (04) : 499 - 500
  • [25] Microdosimetry in X-ray synchrotron based binary radiation therapy
    Hugtenburg, R. P.
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : S126 - S128
  • [26] Dose calculation algorithm for a compact x-ray source in Microbeam Radiation Therapy
    Ahmed, M.
    Wilkens, J. J.
    Bartzsch, S.
    Combs, S. E.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S751 - S752
  • [27] Active Shape Model-based segmentation of digital X-ray images
    Behiels, G
    Vandermeulen, D
    Maes, F
    Suetens, P
    Dewaele, P
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 128 - 137
  • [28] Statistical shape model-based segmentation of digital X-ray images
    Behiels, C
    Vandermeulen, D
    Suetens, P
    IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, PROCEEDINGS, 2000, : 61 - 68
  • [29] Statistical modeling challenges in model-based reconstruction for X-ray CT
    Zhang, Ruoqiao
    Chang, Aaron
    Thibault, Jean-Baptiste
    Sauer, Ken
    Bouman, Charles
    COMPUTATIONAL IMAGING XI, 2013, 8657
  • [30] Model-based bone segmentation from digital X-Ray images
    El-Kwae, EA
    Tzacheva, A
    Kellam, JF
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 2529 - 2530