Acetabular revision using a total acetabular allograft

被引:1
|
作者
Malhotra, Rajesh [1 ]
Kumar, Vijay [1 ]
机构
[1] All India Inst Med Sci, Dept Orthopaed, New Delhi 110029, India
关键词
Acetabular revision; revision hip arthroplasty; total acetabular allograft; total hip replacement; TOTAL HIP-ARTHROPLASTY; 5-YEAR FOLLOW-UP; RECONSTRUCTION; COMPONENT; SURGERY;
D O I
10.4103/0019-5413.50860
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The most challenging aspect of an acetabular revision is the management of severe bone loss, which compromises implant fixation and stability. We present a case of failed acetabular revision with extensive bone loss (Paprosky Type 3b) in a 50-year-old woman with rheumatoid arthritis, which was treated using total acetabular allograft. At a follow-up of 1 year and 3 months, the allograft had united with the host bone. This is the first report of the use of a total acetabular allograft for revision total hip arthroplasty in India. The total acetabular allograft allows the placement of the component closer to the normal hip center, provides initial stability for the acetabular component, and restores bone stock to the host pelvis.
引用
收藏
页码:218 / 221
页数:4
相关论文
共 50 条
  • [22] Treatment of Acetabular Bone Defect in Revision of Total Hip Arthroplasty Using 3D Printed Tantalum Acetabular Augment
    Ying, Jiawei
    Cheng, Liangliang
    Li, Junlei
    Wu, Bin
    Qiu, Xing
    Zhang, Tianwei
    Wang, Feng
    Liu, Baoyi
    Yang, Lei
    Pokharel, Durga Bhakta
    Xie, Hui
    Wang, Fuyang
    Liu, Yuchen
    Xu, Minghao
    Yu, Haiyu
    Zhao, Dewei
    ORTHOPAEDIC SURGERY, 2023, 15 (05) : 1264 - 1271
  • [23] Acetabular revision using a bone-ingrowth total hip component in patients who have acetabular bone stock deficiency
    Woolson, ST
    Adamson, GJ
    JOURNAL OF ARTHROPLASTY, 1996, 11 (06): : 661 - 667
  • [24] The management of severe acetabular bone loss using structural allograft and acetabular reinforcement devices
    Gill, TJ
    Sledge, JB
    Müller, ME
    JOURNAL OF ARTHROPLASTY, 2000, 15 (01): : 1 - 7
  • [25] Cementation of an acetabular liner into a well-fixed acetabular shell during revision total hip arthroplasty
    Springer, BD
    Hanssen, AD
    Lewallen, DG
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 126 - 130
  • [26] COMPRESSED ALLOGRAFT CHIPS FOR ACETABULAR RECONSTRUCTION IN REVISION HIP-ARTHROPLASTY
    AZUMA, T
    YASUDA, H
    OKAGAKI, K
    SAKAI, K
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05): : 740 - 744
  • [27] Effects of Acetabular Screws on the Initial Stability of Porous Coated Acetabular Implants in Revision Total Hip Arthroplasty
    Kaplan, Nathan B.
    Barra, Matthew F.
    Jubril, Ayodeji
    Knapp, Emma
    Awad, Hani
    Ginnetti, John
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (04)
  • [28] Reconstruction at a high hip center in acetabular revision surgery using a cementless acetabular component
    Harris, WH
    ORTHOPEDICS, 1998, 21 (09) : 991 - 992
  • [29] Acetabular Liner Revision Using an Anterolateral Approach
    Shigemura, Tomonori
    Kishida, Shunji
    Nakamura, Junichi
    Takeshita, Munenori
    Takazawa, Makoto
    Harada, Yoshitada
    ORTHOPEDICS, 2012, 35 (04) : E570 - E573
  • [30] Acetabular reinforcement rings associated with allograft for severe acetabular defects
    Gibon, Emmanuel
    Kerboull, Luc
    Courpied, Jean-Pierre
    Hamadouche, Moussa
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (03) : 561 - 571