Spectral Power Analysis of Partial Discharges Waveforms During Electrical Tree Growth Under Different Excitation Frequencies

被引:0
|
作者
Schurch, Roger [1 ]
Munoz, Osvaldo [1 ]
Ardila-Rey, Jorge [2 ]
机构
[1] Univ Tecn Federico Santa Maria, Av Espana 1680, Valparaiso, Chile
[2] Univ Tecn Federico Santa Maria, Av Vicuna Mackenna 3939, Santiago, Chile
关键词
Partial discharges; Electrical trees; Power ratio maps; CABLE INSULATION; XLPE; SEPARATION;
D O I
10.1007/978-3-030-31676-1_84
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical trees are the main mechanism of failure in solid polymeric insulation. Their growth is associated to partial discharge (PD) activity. Measuring and analyzing PDs during tree growth is crucial for the insulation condition assessment and thus, the risk of failure of power equipment. Here, PD pulse waveforms are analyzed using power ratios maps. The aim of the study is to evaluate the ability of power ratio maps to determine the state of progression of electrical trees. Electrical trees were grown in epoxy resin samples at different frequencies, while PDs were measured using very-high frequency (VHF) and ultra-high frequency (UHF) techniques. The progression of the tree was observed using an optical camera and it was correlated with PD data. The results showed that power ratio maps obtained from VHF and UHF signals yield similar patterns. Especially in VHF, it was observed that the centroids of the clusters associated to each stage of tree-growth moved with tree-progression. PDs at the beginning of tree-growth were located at the top-right of power maps, while in more advanced stages, they were located more to the bottom-center of the maps. This means that the PD pulse waveform had higher frequency content in the beginning than in the end of tree growth. In base of this initial results, it is concluded that power ratio maps are sensitive to the state of growth of electrical trees, and thus, can be used for assessing the risk of failure of insulation subjected to electrical treeing degradation mechanism.
引用
收藏
页码:899 / 907
页数:9
相关论文
共 50 条
  • [11] Characterization of Electrical Tree Initiation and Growth in XLPE Under Harmonic Waveforms
    Arachchige, Thanuja Gawasingha
    Zhong, Xin
    Ekanayake, Chandima
    Ma, Hui
    Saha, Tapan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (05) : 1974 - 1982
  • [12] Detection and Analysis of Partial Discharges under PWM Voltage Excitation
    Yang, Mengchen
    Phung, B. T.
    PROCEEDINGS OF 2021 5TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (IEEE CATCON 2021), 2021, : 298 - 302
  • [13] Characteristics of Partial Discharge in XLPE during Electrical Tree Initiation Process under Different Temperatures
    Peng, Suman
    Zhu, Xi
    Wu, Jiandong
    Yin, Yi
    PROCEEDINGS OF 2020 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2020), 2020, : 561 - 564
  • [14] Partial discharge characteristics during electrical tree growth in LDPE
    Zheng, Hualong
    Rowland, Simon
    2018 IEEE 2ND INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), 2018,
  • [15] Preliminary Investigations of the Electrical Tree Growth at Frequencies of 50 Hz and 2.2 kHz by means of Partial Discharge Analysis
    Gallesi, Federico
    Guastavino, Francesco
    Nett, Isabella
    Puffer, Ralf
    Soppe, Bastian
    Vocke, Jan
    2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 469 - 472
  • [16] A Comparative Study of Partial Discharges Under Power and Very Low Frequency Voltage Excitation
    Dao, Thinh
    Phung, B. T.
    Blackburn, T.
    Nguyen, H. V. P.
    2014 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2014, : 164 - 167
  • [17] Influence of different square voltage waveforms on the partial discharges behaviour during tests on twisted pair specimens
    Coletti, G
    Guastavino, F
    Torello, E
    CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 36 - 39
  • [18] A new monitoring and characterization system of partial discharges based on the analysis of the spectral power
    Ardila-Rey, J. A.
    Albarracin, R.
    Robles, G.
    Martinez-Tarifa, J. M.
    INGENIERIA E INVESTIGACION, 2015, 35 : 13 - 20
  • [19] The Influence of Electrical Equipment Insulation Aging Degree on the Growth Rate of Partial Discharges Power
    Fedosov, E. M.
    Sattarov, R. R.
    Volkova, T. A.
    2016 2ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2016,
  • [20] Electrical tree growth under very low frequency (VLF) voltage excitation
    Schurch, Roger
    Donoso, Pablo
    Ardila-Rey, Jorge
    Montana, Johny
    Angulo, Alejandro
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 338 - 341