Spectral Power Analysis of Partial Discharges Waveforms During Electrical Tree Growth Under Different Excitation Frequencies

被引:0
|
作者
Schurch, Roger [1 ]
Munoz, Osvaldo [1 ]
Ardila-Rey, Jorge [2 ]
机构
[1] Univ Tecn Federico Santa Maria, Av Espana 1680, Valparaiso, Chile
[2] Univ Tecn Federico Santa Maria, Av Vicuna Mackenna 3939, Santiago, Chile
关键词
Partial discharges; Electrical trees; Power ratio maps; CABLE INSULATION; XLPE; SEPARATION;
D O I
10.1007/978-3-030-31676-1_84
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical trees are the main mechanism of failure in solid polymeric insulation. Their growth is associated to partial discharge (PD) activity. Measuring and analyzing PDs during tree growth is crucial for the insulation condition assessment and thus, the risk of failure of power equipment. Here, PD pulse waveforms are analyzed using power ratios maps. The aim of the study is to evaluate the ability of power ratio maps to determine the state of progression of electrical trees. Electrical trees were grown in epoxy resin samples at different frequencies, while PDs were measured using very-high frequency (VHF) and ultra-high frequency (UHF) techniques. The progression of the tree was observed using an optical camera and it was correlated with PD data. The results showed that power ratio maps obtained from VHF and UHF signals yield similar patterns. Especially in VHF, it was observed that the centroids of the clusters associated to each stage of tree-growth moved with tree-progression. PDs at the beginning of tree-growth were located at the top-right of power maps, while in more advanced stages, they were located more to the bottom-center of the maps. This means that the PD pulse waveform had higher frequency content in the beginning than in the end of tree growth. In base of this initial results, it is concluded that power ratio maps are sensitive to the state of growth of electrical trees, and thus, can be used for assessing the risk of failure of insulation subjected to electrical treeing degradation mechanism.
引用
收藏
页码:899 / 907
页数:9
相关论文
共 50 条
  • [1] Electrical tree growth under harmonic frequencies characterized by partial discharges waveforms
    Schurch, Roger
    Munoz, Osvaldo
    Ardila-Rey, Jorge
    2020 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (2020 IEEE CEIDP), 2020, : 168 - 171
  • [2] Partial Discharges Behavior Under Different Rectified Waveforms
    Imburgia, Antonino
    Romano, Pietro
    Viola, Fabio
    Hozumi, Naohiro
    Morita, Shosuke
    2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 114 - 117
  • [3] Partial discharges mechanisms under different voltage waveforms
    Guastavino, F
    Torello, E
    del Casale, MD
    Egiziano, L
    PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING TECHNOLOGY CONFERENCE, 2003, : 353 - 357
  • [4] Analysis of Partial Discharges in Electrical Tree Growth Under Very Low Frequency (VLF) Excitation Through Pulse Sequence and Nonlinear Time Series Analysis
    Donoso, Pablo
    Schurch, Roger
    Ardila, Jorge
    Orellana, Luis
    IEEE ACCESS, 2020, 8 : 163673 - 163684
  • [5] Simulation of partial discharges and electrical tree growth in solid insulation under AC voltage
    Malinovski, AS
    Noskov, MD
    Sack, M
    Schwab, AJ
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, 1998, : 305 - 308
  • [6] Investigations of the Electrical Tree Growth at Different Voltages and Frequencies
    Gallesi, Federico
    Guastavino, Francesco
    Torello, Eugenia
    Nett, Isabella
    Soppe, Bastian
    Vocke, Jan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (06) : 2490 - 2497
  • [7] Electrical Tree Growth and Partial Discharge in Epoxy Resin Under Combined AC and DC Voltage Waveforms
    Iddrissu, Ibrahim
    Rowland, Simon M.
    Zheng, Hualong
    Lv, Zepeng
    Schurch, Roger
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (06) : 2183 - 2190
  • [8] Acoustic emission measurement of partial discharges during electrical tree growth in XLPE cable insulation
    Tian, Y
    Lewin, PL
    Davies, AE
    Hathaway, GM
    Sutton, SJ
    Swingler, SG
    ICSD '01: PROCEEDINGS OF THE 2001 IEEE 7TH INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, 2001, : 477 - 480
  • [9] Electrical tree growth and partial discharges analyzed by fractal and correlation dimensions
    Schurch, Roger
    Donoso, Pablo
    Aguirre, Pablo
    Cardenas, O'Bryan
    Zuniga, Marcos
    Rowland, Simon M.
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 785 - 788
  • [10] Core Loss Characteristics Analysis of Power Transformer Under Different Frequencies Excitation
    Hasan, Syafruddin
    Taib, Soib
    Hardi, Surya
    Rahim A. R, A.
    Shukri, Ahmad
    PROCEEDINGS OF THE 2013 IEEE 7TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO2013), 2013, : 619 - 623