A Robust Fractional-Order PID Controller Based Load Frequency Control Using Modified Hunger Games Search Optimizer

被引:20
|
作者
Fathy, Ahmed [1 ]
Yousri, Dalia [2 ]
Rezk, Hegazy [3 ,4 ]
Thanikanti, Sudhakar Babu [5 ]
Hasanien, Hany M. [6 ]
机构
[1] Jouf Univ, Fac Engn, Elect Engn Dept, Sakaka 42421, Saudi Arabia
[2] Fayoum Univ, Fac Engn, Dept Elect Engn, Al Fayyum 63514, Egypt
[3] Prince Sattam Bin Abdulaziz Univ, Coll Engn Wadi Addawaser, Al Kharj 11942, Saudi Arabia
[4] Minia Univ, Fac Engn, Elect Engn Dept, Al Minya 61519, Egypt
[5] Chaitanya Bharathi Inst Technol CBIT, Dept Elect & Elect Engn, Hyderabad 500075, India
[6] Ain Shams Univ, Fac Engn, Elect Power & Machines Dept, Cairo 11517, Egypt
关键词
multi-interconnected system; load frequency control; FOPID; hunger games search optimizer; renewable energy plants; AUTOMATIC-GENERATION CONTROL; MULTI-INTERCONNECTED PLANTS; DAMPED WAVE ALGORITHM; POWER-SYSTEMS; ELECTRIC VEHICLES; DESIGN; AGC;
D O I
10.3390/en15010361
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this article, a recent modified meta-heuristic optimizer named the modified hunger games search optimizer (MHGS) is developed to determine the optimal parameters of a fractional-order proportional integral derivative (FOPID) based load frequency controller (LFC). As an interconnected system's operation requires maintaining the tie-line power and frequency at their described values without permitting deviations in them, an enhanced optimizer is developed to identify the controllers' parameters efficiently and rapidly. Therefore, the non-uniform mutation operator is proposed to strengthen the diversity of the solutions and discover the search landscape of the basic hunger games search optimizer (HGS), aiming to provide a reliable approach. The considered fitness function is the integral time absolute error (ITAE) comprising the deviations in tie-line power and frequencies. The analysis is implemented in two networks: the 1st network comprises a photovoltaic (PV) plant connected to the thermal plant, and the 2nd network has four connected plants, which are PV, wind turbine (WT), and 2 thermal units with generation rate constraints and governor dead-band. Two different load disturbances are imposed for two studied systems: static and dynamic. The results of the proposed approach of MHGS are compared with the marine predators algorithm (MPA), artificial ecosystem based optimization (AEO), equilibrium optimizer (EO), and Runge-Kutta based optimizer (RUN), as well as movable damped wave algorithm (DMV) results. Moreover, the performance specifications of the time responses of frequencies and tie-line powers' violations comprising rise time, settling time, minimum/maximum setting values, overshoot, undershoot, and the peak level besides its duration are calculated. The proposed MHGS shows its reliability in providing the most efficient values for the FOPID controllers' parameters that achieve the lowest fitness of 0.89726 in a rapid decaying. Moreover, the MHGS based system becomes stable the most quickly as it has the shortest settling time and is well constructed as it has the smallest peak, overshoots at early times, and then the system becomes steady. The results confirmed the competence of the proposed MHGS in designing efficient FOPID-LFC controllers that guarantee reliable operation in case of load disturbances.
引用
收藏
页数:25
相关论文
共 50 条
  • [21] Optimization of Fractional Order PID Controller Using Grey Wolf Optimizer
    Verma S.K.
    Yadav S.
    Nagar S.K.
    Journal of Control, Automation and Electrical Systems, 2017, 28 (3) : 314 - 322
  • [22] Fractional-order PID Controller Design using PSO and GA
    Nasir, Mohannad
    Khadraoui, Sofiane
    2021 14TH INTERNATIONAL CONFERENCE ON DEVELOPMENTS IN ESYSTEMS ENGINEERING (DESE), 2021, : 192 - 197
  • [23] Data-Driven Robust Servo Tuning Method Using Fractional-Order PID Controller
    Jinai, K.
    Kawaguchi, N.
    Arrieta, O.
    Sato, T.
    IFAC PAPERSONLINE, 2024, 58 (07): : 436 - 441
  • [24] Robust Fractional-Order Proportional-Integral Controller Tuning for Load Frequency Control of a Microgrid System with Communication Delay
    Ruan, Shitao
    ENERGIES, 2023, 16 (14)
  • [25] A robust fractional-order PID controller design based on active queue management for TCP network
    Hamidian, Hamideh
    Beheshti, Mohammad T. H.
    INTERNATIONAL JOURNAL OF SYSTEMS SCIENCE, 2018, 49 (01) : 211 - 216
  • [26] Robust Fractional-Order PID Controller Tuning Based on Bode's Optimal Loop Shaping
    Liu, Lu
    Zhang, Shuo
    COMPLEXITY, 2018,
  • [27] Novel chaos game optimization tuned-fractional-order PID fractional-order PI controller for load-frequency control of interconnected power systems
    Barakat, Mohamed
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2022, 7 (01)
  • [28] Load frequency control and automatic generation control using fractional-order controllers
    Alomoush, Muwaffaq Irsheid
    ELECTRICAL ENGINEERING, 2010, 91 (07) : 357 - 368
  • [29] Load frequency control and automatic generation control using fractional-order controllers
    Muwaffaq Irsheid Alomoush
    Electrical Engineering, 2010, 91 (7) : 357 - 368
  • [30] Load Frequency Control using PID Controller
    Khairnar, Hitesh
    Patil, Gaurav B.
    Ghugare, Suraj
    More, Bhushan
    Ushkewar, Sandeep
    Mali, Manas
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE COMPUTING AND SMART SYSTEMS, ICSCSS 2024, 2024, : 190 - 195