Web Server for Peak Detection, Baseline Correction, and Alignment in Two-Dimensional Gas Chromatography Mass Spectrometry-Based Metabolomics Data

被引:15
|
作者
Tian, Tze-Feng [1 ,2 ]
Wang, San-Yuan [1 ,2 ]
Kuo, Tien-Chueh [2 ,5 ]
Tan, Cheng-En [1 ,2 ]
Chen, Guan-Yuan [2 ,3 ]
Kuo, Ching-Hua [2 ,3 ,4 ]
Chen, Chi-Hsin Sally [6 ]
Chan, Chang-Chuan [6 ]
Lin, Olivia A. [5 ]
Tseng, Y. Jane [1 ,2 ,3 ,5 ]
机构
[1] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, 1,Sec 4,Roosevelt Rd, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Ctr Genom Med, Metabol Core Lab, 2 Syu Jhou Rd, Taipei 10055, Taiwan
[3] Natl Taiwan Univ, Sch Pharm, Coll Med, 33 Linsen S Rd, Taipei 100, Taiwan
[4] Natl Taiwan Univ, Natl Taiwan Univ Hosp, Dept Pharm, 1 Changde St, Taipei 10048, Taiwan
[5] Natl Taiwan Univ, Grad Inst Biomed Elect & Bioinformat, 1,Sec 4,Roosevelt Rd, Taipei 10617, Taiwan
[6] Natl Taiwan Univ, Inst Occupat Med & Ind Hyg, 17 Xuzhou Rd, Taipei 100, Taiwan
关键词
CHEMOMETRIC ANALYSIS; MS DATA; METABOLITES; GC; ALGORITHM; ELECTROPHORESIS; IDENTIFICATION; SEPARATIONS; SIMILARITY; SAMPLES;
D O I
10.1021/acs.analchem.6b00755
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two-dimensional gas chromatography time-of-flight mass spectrometry (GCXGC/TOF-MS) is superior for chromatographic separation and provides great sensitivity for complex biological fluid analysis in metabolomics. However, GCXGC/TOF-MS data processing is currently limited to vendor software and typically requires several preprocessing steps. In this work, we implement a web-based platform, which we call GC(2)MS, to facilitate the application of recent advances in GCXGC/TOF-MS, especially for metabolomics studies. The core processing workflow of GC(2)MS consists of blob/peak detection, baseline correction, and blob alignment. GC(2)MS treats GCXGC/TOF-MS data as pictures and clusters the pixels as blobs according to the brightness of each pixel to generate a blob table. GC(2)MS then aligns the blobs of two GCXGC/TOF-MS data sets according to their distance and similarity. The blob distance and similarity are the Euclidean distance of the first and second retention times of two blobs and the Pearsons correlation coefficient of the two mass spectra, respectively. GC(2)MS also directly corrects the raw data baseline. The analytical performance of GC(2)MS was evaluated using GCXGC/TOF-MS data sets of Angelica sinensis compounds acquired under different experimental conditions and of human plasma samples. The results show that GC(2)MS is an easy-to-use tool for detecting peaks and correcting baselines, and GC(2)MS is able to align GCXGC/TOF-MS data sets acquired under different experimental conditions. GC(2)MS is freely accessible at http://gc2ms.web.cmdm.tw.
引用
收藏
页码:10395 / 10403
页数:9
相关论文
共 50 条
  • [41] Baseline Correction Method Using an Orthogonal Basis for Gas Chromatography/Mass Spectrometry Data
    Xu, Zhanfeng
    Sun, Xiaobo
    Harrington, Peter de B.
    ANALYTICAL CHEMISTRY, 2011, 83 (19) : 7464 - 7471
  • [42] Comprehensive two-dimensional gas chromatography-mass spectrometry: A review
    Mondello, Luigi
    Tranchida, Peter Quinto
    Dugo, Paola
    Dugo, Giovanni
    MASS SPECTROMETRY REVIEWS, 2008, 27 (02) : 101 - 124
  • [43] Two-Dimensional Gas Chromatography Coupled With Mass Spectrometry in Food Analysis
    Dymerski, Tomasz
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2018, 48 (04) : 252 - 278
  • [44] Higher mass loadability in comprehensive two-dimensional gas chromatography-mass spectrometry for improved analytical performance in metabolomics analysis
    Koek, Maud M.
    Muilwijk, Bastiaan
    van Stee, Leo L. P.
    Hankemeier, Thomas
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) : 420 - 429
  • [45] Differential metabolomics using stable isotope labeling and two-dimensional gas chromatography, with time-of-flight mass spectrometry
    Huang, Xiaodong
    Regnier, Fred E.
    ANALYTICAL CHEMISTRY, 2008, 80 (01) : 107 - 114
  • [46] Odour fingerprint acquisition by means of comprehensive two-dimensional gas chromatography-olfactometry and comprehensive two-dimensional gas chromatography/mass spectrometry
    Zellner, Barbara d'Acampora
    Casilli, Alessandro
    Dugo, Paola
    Dugo, Giovanni
    Mondello, Luigi
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1141 (02) : 279 - 286
  • [47] Qualitative and quantitative analysis of vetiver essential oils by comprehensive two-dimensional gas chromatography and comprehensive two-dimensional gas chromatography/mass spectrometry
    Filippi, Jean-Jacques
    Belhassen, Emilie
    Baldovini, Nicolas
    Brevard, Hugues
    Meierhenrich, Uwe J.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1288 : 127 - 148
  • [48] Profiling of soil fatty acids using comprehensive two-dimensional gas chromatography with mass spectrometry detection
    Zeng, Annie Xu
    Chin, Sung-Tong
    Patti, Antonio
    Marriott, Philip J.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1317 : 239 - 245
  • [49] Data Analysis Tool for Comprehensive Two-Dimensional Gas Chromatography/Time-of-Flight Mass Spectrometry
    Castillo, Sandra
    Mattila, Ismo
    Miettinen, Jarkko
    Oresic, Matej
    Hyotylainen, Tuulia
    ANALYTICAL CHEMISTRY, 2011, 83 (08) : 3058 - 3067
  • [50] Fast, high peak capacity separations in comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry
    Fitz, Brian D.
    Wilson, Ryan B.
    Parsons, Brendon A.
    Hoggard, Jamin C.
    Synovec, Robert E.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1266 : 116 - 123