A COMPREHENSIVE SOLUTION FOR DEVELOPMENT OF LARGE SCALE GRID-CONNECTED PV GENERATION IN CHINA

被引:1
|
作者
Wang Qiankun [1 ]
机构
[1] State Grid Energy Res Inst, Beijing 100051, Peoples R China
关键词
Distributed PV; Integration; Comprehensive Solution;
D O I
10.1260/0958-305X.26.1-2.83
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To combat climate change and fulfill the national target of having 15% of primary energy from non-fossil fuels by 2020, China's central government is making every effort to promote PV generation, especially in the context of deteriorating export markets for China's PV industry, resulting from anti-dumping and anti-subsidy campaigns launched by United States and European Union. PV generation PV generation is set to boom in coming years in China. Although there is ambitious planning of building large scale ground-mounted PV plants in the Northwest of China, more than half of the installations are expected to be customer-sited small scale distributed systems. Because PV generation, particularly customer-sited PV systems represents a totally new pattern of power production and consumption. China's electricity system, which has been originally designed for centralized power delivery, is not fully prepared to accommodate large scale PV generation from the technical point of view. Besides, governmental policies and operational regulations are not able to match the need of these new comers. This paper works out a comprehensive solution for integration of large scale distributed PV, which consists of technical strategy, regulatory strategy and policy strategy. Firstly, electricity grids and PV systems should be directionally technically adapted to each other. oGrid friendly PV plants" requires that PV plants should be equipped with advanced technologies to improve the visibility, controllability and predictability, bringing the performance of PV plants increasingly close to that of conventional power plants. Secondly, with high penetration of distributed PV generation, grid dispatch centers should have necessary monitoring and control over these dispersed generating systems, which are supposed to follow the instructions issued by grid operators. Thirdly, incentive polies should be in accordance with national medium-and long term planning, with consideration of minimizing social cost. Policies should also be foreseeable and persistent for all the investors. Based on the framework of the comprehensive solution for PV generation, this paper elaborates major experience drawn from Germany with high PV penetration and illustrates how Germany has successfully integrated large scale distributed PV systems from the technical, regulatory and policy aspect respectively. Finally, it comes up with relevant recommendations for the development of PV generation in China: to speed up the process of establishing and improving the system of technical requirements, to draw up and release detailed operational rules on distributed PV generating systems and replace unified FIT for ground-mounted systems with differentiated FIT. Distributed customer-sited PV systems should be promoted by subsidizing the self-consumed electricity in the form of RMB cent per kWh.
引用
收藏
页码:83 / 94
页数:12
相关论文
共 50 条
  • [31] A Single-Phase Grid-Connected PV Inverter with Improved Grid-connected Current
    Xiao, Furong
    Dong, Lei
    Liao, Xiaozhong
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 4083 - 4088
  • [32] On the Comprehensive Reactive Power Compensation System of Large-scale Grid-connected Wind Power
    Li Chengwei
    Zhou Zhe
    Liu Mingyuan
    PROCEEDINGS OF THE 2015 3RD INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND INFORMATION TECHNOLOGY APPLICATIONS, 2015, 35 : 1169 - 1172
  • [33] Analysis on interaction affect of large scale grid-connected wind farm, PV plant and HVDC systems
    Miao, Miao
    Li, Xingyuan
    Wang, Xi
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2015, 36 (04): : 878 - 885
  • [34] Dynamic Modelling of Distributed PV Grid-connected System With Large Scale of Panel Level DC Optimizers
    Wang Q.
    Yao W.
    Ai X.
    Fang J.
    Wen J.
    Yang X.
    Xie H.
    Huang X.
    Yao, Wei (w.yao@hust.edu.cn), 1600, Power System Technology Press (45): : 559 - 569
  • [35] A Comprehensive Review of Grid-Connected PV Systems Based on Impedance Source Inverter
    Jamal, Ihab
    Elmorshedy, Mahmoud F.
    Dabour, Sherif M.
    Rashad, Essam M.
    Xu, Wei
    Almakhles, Dhafer J.
    IEEE ACCESS, 2022, 10 : 89101 - 89123
  • [36] A Comprehensive Assessment of the Short-Term Uncertainty of Grid-Connected PV Systems
    Scolari, Enrica
    Reyes-Chamorro, Lorenzo
    Sossan, Fabrizio
    Paolone, Mario
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2018, 9 (03) : 1458 - 1467
  • [37] A Low Cost Solution to Grid-connected Distributed Generation Inverters
    Shen, Guoqiao
    Zhang, Jun
    Zhu, Xuancai
    Xu, Dehong
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 503 - 508
  • [38] Power System Probabilistic Production Simulation Including Large Scale Grid-connected Photovoltaic Generation
    Hong, Fan
    Ru, Lu
    Jiang Yanbin
    PROCEEDINGS OF THE 2016 IEEE 11TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2016, : 2066 - 2070
  • [39] Large-Scale Modeling of Grid-Connected Electric Vehicles
    Rolink, Johannes
    Rehtanz, Christian
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 894 - 902
  • [40] Reliability of large-scale grid-connected photovoltaic systems
    Zini, Gabriele
    Mangeant, Christophe
    Merten, Jens
    RENEWABLE ENERGY, 2011, 36 (09) : 2334 - 2340