Rapid determination of uranium isotopes in calcium fluoride sludge by tandem quadrupole ICP-MS/MS

被引:14
|
作者
Xing, Shan [1 ]
Luo, Maoyi [1 ,2 ]
Wu, Yang [1 ]
Liu, Daqian [1 ]
Dai, Xiongxin [1 ,2 ]
机构
[1] China Inst Radiat Protect, Taiyuan 030000, Shanxi, Peoples R China
[2] Jiangsu Higher Educ Inst, Collaborat Innovat Ctr Radiat Med, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
ENVIRONMENTAL-SAMPLES; SEDIMENT SAMPLES; EXTRACTION; ACTINIDES; SPECTROMETRY; PLUTONIUM; DIGESTION; SEAWATER; U-236; SOIL;
D O I
10.1039/c9ja00209j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative analyses of potential radionuclide contaminants in solid wastes (e.g. calcium fluoride sludge) generated by the nuclear industry are essential for clearance or reutilization of these wastes. In order to measure trace uranium isotopes in calcium fluoride sludge, a total sample dissolution method was developed utilizing lithium metaborate fusion and anion exchange chromatography combined with a triple quadrupole ICP-MS/MS instrument. The method was validated using calcium fluoride sludge spiked with known amounts of uranium isotopes. All measured results were in good agreement with the expected values, demonstrating the feasibility of the method for the determination of trace uranium isotopes. The minimum detectable activities of U-234, U-235 and U-238 were determined to be 0.15 mBq (0.65 pg), 0.67 mu Bq (8.38 pg) and 0.014 mBq (1.13 ng), respectively. A key finding was that the sensitivity of uranium (750 Mcps ppm(-1)) with He at a flow rate of 8.5 mL min(-1) was 5 times that achieved by ICP-MS/MS without the collision gas. The investigation of the mechanism of He collision would provide a novel and optimal method to simultaneously improve the sensitivity and suppress interference for the analysis of ultra-low level heavy radionuclides (e.g., uranium, plutonium, and americium) combined with reaction gasses (e.g., CO2, O-2, and NH3).
引用
收藏
页码:2027 / 2034
页数:8
相关论文
共 50 条
  • [21] Method for the Determination of Thorium and Uranium in Urine by ICP-MS
    Schramel, P.
    Wendler, I.
    Roth, P.
    Werner, E.
    Mikrochimica Acta, 1997, 126 (03): : 263 - 266
  • [22] Rapid analysis of 237Np and Pu isotopes in small volume urine by SF- ICP-MS and ICP-MS/MS
    Yang, Guosheng
    Zheng, Jian
    Kim, Eunjoo
    Zhang, Shuai
    Seno, Hatsuho
    Kowatari, Munehiko
    Aono, Tatsuo
    Kurihara, Osamu
    ANALYTICA CHIMICA ACTA, 2021, 1158
  • [23] Accurate Determination of Plutonium in Soil by Tandem Quadrupole ICP-MS with Different Sample Preparation Methods
    Xing, Shan
    Luo, Maoyi
    Yuan, Ni
    Liu, Daqian
    Yang, Yao
    Dai, Xiongxin
    Zhang, Weichao
    Chen, Ning
    ATOMIC SPECTROSCOPY, 2021, 42 (02) : 62 - 70
  • [24] Rapid determination of 237Np and Pu isotopes in environmental samples by ICP-MS
    Kim, CS
    Kim, CK
    Rho, BW
    Lee, KJ
    PLUTONIUM FUTURES - THE SCIENCE, 2003, 673 : 406 - 408
  • [25] COMPARISON OF QUADRUPOLE ICP-MS AND MAGNETIC-SECTOR ICP-MS FOR THE ANALYSIS OF U-TH SERIES ISOTOPES IN NATURAL SAMPLES
    SHAW, TJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 105 - NUCL
  • [26] An emergency radiobioassay method for Pu, Am and Cm isotopes in urine samples using tandem quadrupole ICP-MS
    Wu, Yang
    Dai, Xiongxin
    Luo, Maoyi
    Guo, Hongmei
    Yuan, Ni
    Yang, Yonggang
    He, Jingjing
    Guo, Yuanyuan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (02) : 513 - 519
  • [27] Determination of lead isotopes ratio in rock samples by ICP-MS
    Zheng, Pei-Xi
    Zhou, Yan
    Wang, Tie-Fu
    Liu, Li
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A1522 - A1522
  • [28] DETERMINATION OF ULTRATRACE AMOUNTS OF URANIUM AND THORIUM IN MOLYBDENUM BY ICP-MS
    KAWAMURA, T
    BUNSEKI KAGAKU, 1988, 37 (11) : 585 - 588
  • [29] ON ICP-MS DETERMINATION OF URANIUM IN DRINKING, GROUND AND MINERAL WATERS
    Georgiev, Valentin
    Dakova, Ivanka
    Karadjova, Irina
    COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2023, 76 (04): : 525 - 531
  • [30] Overcoming spectral overlaps: Quadrupole ICP-MS with reaction cell and sector based ICP-MS
    Olesik, JW
    Jones, D
    PLASMA SOURCE MASS SPECTROMETRY: APPLICATIONS AND EMERGING TECHNOLOGIES, 2003, : 261 - 270