Endovascular Stent-Graft Repair of Major Abdominal Arteriovenous Fistula: A Systematic Review

被引:41
|
作者
Antoniou, George A. [1 ]
Koutsias, Stylianos [1 ]
Karathanos, Christos [1 ]
Sfyroeras, Giorgos S. [1 ]
Vretzakis, Georgios [2 ]
Giannoukas, Athanasios D. [1 ]
机构
[1] Univ Thessaly, Sch Med, Univ Hosp Larissa, Dept Vasc Surg, Larisa 41110, Greece
[2] Univ Thessaly, Sch Med, Univ Hosp Larissa, Dept Anesthesiol, Larisa 41110, Greece
关键词
aortocaval fistula; abdominal aortic aneurysm; aneurysm; arteriovenous fistula; endovascular aneurysm repair; stent-graft; INFERIOR VENA-CAVA; RENAL-VEIN FISTULA; PRIMARY AORTOCAVAL FISTULA; AORTOILIAC ANEURYSM; AORTIC-ANEURYSMS; ENDOGRAFT PLACEMENT; MANAGEMENT; SURGERY;
D O I
10.1583/09-2725.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To evaluate the outcomes of endovascular stent-graft repair of major abdominal arteriovenous fistulas. Methods: The English literature was systematically searched using the MEDLINE electronic database up to January 2009. All reports on endovascular stent-graft repair of major abdominal arteriovenous fistula were considered. Our experience of abdominal arteriovenous fistula was involved in the data analysis. The primary outcome measures were technical success and perioperative, 30-day, and overall mortality. Results: Data for the final analysis were extracted from 21 papers reporting on 22 patients and from the medical records of a patient treated at our institution. The most common causal associations of these fistulae were the presence of an aortoiliac aneurysm and previous endovascular aneurysm repair, accounting for 56% and 13% of all associations, respectively. The technical success rate was 96% (22/23). No perioperative or 30-day mortality was noticed during a mean follow-up of 9 months. The most common procedure-related complication was type II endoleak, which was found in 22% (5/23) of the patients. This event was either self limiting or required minimal percutaneous intervention. Conclusion: Endovascular stent-graft repair of major abdominal arteriovenous fistula is a safe and effective treatment option, with good short- and midterm results. However, no long-term data exist, and larger series are required to draw solid conclusions regarding the outcomes of this method. J Endovasc Ther. 2009;16:514-523
引用
收藏
页码:514 / 523
页数:10
相关论文
共 50 条
  • [31] Predictive risk factors for stent-graft distortion associated with stent-graft migration following endovascular repair of abdominal aortic aneurysm
    Higashiura, W
    Kichikawa, K
    Sakaguchi, S
    Kubota, Y
    Ide, K
    Ohishi, H
    RADIOLOGY, 2001, 221 : 200 - 200
  • [32] Surgical Repair of a Post-traumatic Arteriovenous Fistula Complicated by Stent-Graft Misplacement
    Sinan Şahin
    Bayer Çı ınar
    Şule N. Bilgin
    Levent Çelik
    Ergin E. Eren
    CardioVascular and Interventional Radiology, 2005, 28 : 87 - 89
  • [33] Aortoesophageal fistula successfully treated by endovascular stent-graft
    Metz, Roderik
    Kimmings, A. Nikola
    Verhagen, Hence J. M.
    Rinkes, Inne H. M. Borel
    van Hillegersberg, Richard
    ANNALS OF THORACIC SURGERY, 2006, 82 (03): : 1117 - 1119
  • [34] Surgical repair of a post-traumatic arteriovenous fistula complicated by stent-graft misplacement
    Sahin, S
    Çinar, B
    Bilgin, SN
    Çelik, L
    Eren, EE
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 28 (01) : 87 - 89
  • [35] Tracheo-innominate artery fistula successfully treated by endovascular stent-graft repair
    Nakai, Motoki
    Sato, Hirotatsu
    Sato, Morio
    Ikoma, Akira
    Sanda, Hiroki
    Nakata, Kohei
    Minamiguchi, Hiroki
    Kawai, Nobuyuki
    Sonomura, Tetsuo
    Nishimura, Yoshiharu
    Okamura, Yoshitaka
    JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (01) : 65 - 70
  • [36] Tracheo-innominate artery fistula successfully treated by endovascular stent-graft repair
    Motoki Nakai
    Hirotatsu Sato
    Morio Sato
    Akira Ikoma
    Hiroki Sanda
    Kohei Nakata
    Hiroki Minamiguchi
    Nobuyuki Kawai
    Tetsuo Sonomura
    Yoshiharu Nishimura
    Yoshitaka Okamura
    Japanese Journal of Radiology, 2013, 31 : 65 - 70
  • [37] Stent-graft repair for abdominal aortic aneurysm
    Kalman, PG
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1999, 161 (09) : 1133 - 1133
  • [38] Endovascular Repair of Abdominal Aortic Aneurysms With Reverse Taper Neck Anatomy Using the Endurant Stent-Graft: Analysis of Stent-Graft Oversizing
    Mwipatayi, Bibombe P.
    Picardo, Alarick
    Wong, Jackie
    Thomas, Shannon D.
    Vijayan, Vikram
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (04) : 514 - 522
  • [39] Endovascular stent-graft repair with a flexible stent-graft and a simple applicator prepared from a syringe
    Moriyama, Y
    Iguro, Y
    Yotsumoto, G
    Watanabe, S
    Yamamoto, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (03): : 620 - 621
  • [40] Endovascular stent-graft repair for abdominal aortic aneurysm in a patient with cardiac and renal dysfunction
    Handa N.
    Tomita S.
    Kato M.
    Nishio I.
    Asano M.
    Ueno Y.
    General Thoracic and Cardiovascular Surgery, 2009, 57 (4) : 203 - 207