Fosfomycin Susceptibility Testing Using Commercial Agar Dilution Test

被引:7
|
作者
Croughs, Peter D. [1 ]
Konijnendijk-de Regt, Michelle [1 ]
Yusuf, Erlangga [1 ]
机构
[1] Erasmus MC, Dept Med Microbiol & Infect Dis, Rotterdam, Netherlands
来源
MICROBIOLOGY SPECTRUM | 2022年 / 10卷 / 02期
关键词
fosfomycin; antimicrobial susceptibility testing; agar dilution; STAPHYLOCOCCUS-AUREUS; ENTEROBACTERALES;
D O I
10.1128/spectrum.02504-21
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The reference standard for fosfomycin antimicrobial susceptibility testing (AST) is agar dilution, but it is laborious and is not routinely used in diagnostic microbiology. In this study, we evaluated the performance of a ready-to-use commercially available agar dilution kit for fosfomycin AST (Liofilchem Diagnostics). We compared this kit with the reference standard agar dilution, performed according to the Clinical & Laboratory Standards Institute (CLSI) in 229 clinical isolates. The isolates were selected to represent both Gram-positive and Gram-negative microorganisms, with various MIC values. It consisted of 43 enterococci (E. faecalis n = 16, E. foecium n = 27), 13 methicillin-resistant S. aureus (MRSA), 118 Enterobacterales (Escherichia colt n = 94, Klebsiella pneumoniae n = 20, and Enterobacter cloacae complex n = 4), 55 Pseudomonas aeruginosa, and three ATCC isolates. Using CLSI breakpoints for enterococci for oral treatment of urinary tract infections, European Committee on Antimicrobial Susceptibility Testing (EUCAST) breakpoints for intravenous dosing for Enterobacterales and Staphylococci, and epidemiological cutoff value for P. aeruginosa, the essential agreement was 87.5%, and 99.6% after discrepancy resolution. There was no very major error, and 1.9% major error before, and 0.9% major error after resolution of discrepancies. The commercial test showed 100% reproducibility. In conclusion, in comparison to the reference standard, the ready-to-use commercially available agar dilution kit for fosfomycin AST showed excellent performance. IMPORTANCE Fosfomycin is increasingly needed to treat infection due to multidrug resistant microorganisms. Yet, the antimicrobial susceptibility test (AST) of fosfomycin is fraught with difficulties or often laborious to perform. An easy-to-use AST method for fosfomycin is thus needed. In this study, we showed that the ready-to-use commercially available agar dilution kit, in comparison to the reference standard, showed excellent performance.
引用
收藏
页数:6
相关论文
共 50 条