Optical coherence tomography to detect epithelial lesions of the main pancreatic duct:: An ex vivo study

被引:20
|
作者
Testoni, PA
Mangiavillano, B
Albarello, L
Arcidiacono, PG
Mariani, A
Masci, E
Doglioni, C
机构
[1] Univ Vita Salute San Raffaele, IRCCS San Raffaele Hosp, Dept Human Pathol, Milan, Italy
[2] Univ Vita Salute San Raffaele, IRCCS San Raffaele Hosp, Div Gastroenterol, Milan, Italy
来源
AMERICAN JOURNAL OF GASTROENTEROLOGY | 2005年 / 100卷 / 12期
关键词
D O I
10.1111/j.1572-0241.2005.00326.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND: Optical coherence tomography (OCT) permits high-resolution, real-time, infrared-generated imaging of tissue microstructures by a probe inserted through the endoscope operative channel. Resolution is approximately 10 mu m and the penetration depth of the near-focus probe is about 1 mm. The probe can be inserted into the main pancreatic duct (MPD) through a standard endoscopic retrograde cholangiopancreatography catheter. AIMS AND METHODS: To assess the ability of OCT to identify the structure of the MPD, to distinguish normal and malignant MPD epithelium, and to assess intra- and interobserver reproducibility of OCT images. Multiple sections of neoplastic and non-neoplastic segments of 10 consecutive surgical pancreatic specimens were obtained from patients with pancreatic head adenocarcinoma who had undergone Whipple resection, and repeated OCT radial and longitudinal scanning was done within 1 h of resection and before pathological examination. We compared 249 good-quality images with 100 histopathological sections. RESULTS: OCT recognized a definite, different pattern in 82.9% of tumor-free and in 97.6% of tumor-involved specimens; sensitivity and specificity for discrimination between adenocarcinoma and normal tissue were 78.6% and 88.9%, respectively. Inflammatory and dysplastic changes of the MPD showed an OCT pattern similar to that of the normal tissue in 53.3% of images. Overall, intraobserver reproducibility ranged from 85.1% to 100% and interobserver reproducibility ranged from 69.9% to 100% and from 89.7% to 100% for tumor-free and tumor-involved segments, respectively. CONCLUSIONS: OCT identified the neoplastic and non-neoplastic MPD layer structure and appeared to be a reproducible technique. In non-neoplastic conditions, OCT appeared unable to differentiate between normal and abnormal tissues in about half of the cases.
引用
收藏
页码:2777 / 2783
页数:7
相关论文
共 50 条
  • [21] Optical coherence tomography and Raman spectroscopy of the ex-vivo retina
    Evans, Julia W.
    Zawadzki, Robert J.
    Liu, Rui
    Chan, James W.
    Lane, Stephen M.
    Werner, John S.
    JOURNAL OF BIOPHOTONICS, 2009, 2 (6-7) : 398 - 406
  • [22] Spectroscopic Optical Coherence Tomography for ex vivo brain tumor analysis
    Lenz, Marcel
    Krug, Robin
    Dillmann, Christopher
    Gerling, Alexandra
    Gerhardt, Nils C.
    Welp, Hubert
    Schmieder, Kirsten
    Hofmann, Martin R.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XV, 2017, 10054
  • [23] Integrated Optical Coherence Tomography and Optical Coherence Microscopy Imaging of Ex Vivo Human Renal Tissues
    Lee, Hsiang-Chieh
    Zhou, Chao
    Cohen, David W.
    Mondelblatt, Amy E.
    Wang, Yihong
    Aguirre, Aaron D.
    Shen, Dejun
    Sheikine, Yuri
    Fujimoto, James G.
    Connolly, James L.
    JOURNAL OF UROLOGY, 2012, 187 (02): : 691 - 699
  • [24] Encrustation of urologic double pigtail catheters—an ex vivo optical coherence tomography (OCT) study
    Markus J. Bader
    Katja Zilinberg
    Patrick Weidlich
    Raphaela Waidelich
    Michaela Püls
    Christian Gratzke
    Christian G. Stief
    Herbert Stepp
    Ronald Sroka
    Lasers in Medical Science, 2013, 28 : 919 - 924
  • [25] INVESTIGATING THE FEASIBILITY OF OPTICAL COHERENCE TOMOGRAPHY TO IDENTIFY PROSTATE CANCER - AN EX-VIVO STUDY
    Patel, Amit
    Otte, Christoph
    Schlaefer, Alexander
    Nir, Dror
    Otte, Sebastian
    Ngo, Thane
    Loke, Tim
    Winkler, Mathias
    JOURNAL OF UROLOGY, 2016, 195 (04): : E476 - E477
  • [26] Optical coherence tomography in the assessment of cutaneous cancer margins of the face: An immediate ex vivo study
    Jerjes, Waseem
    Hamdoon, Zaid
    Al-Rawi, Natheer
    Hopper, Colin
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2020, 29
  • [27] EX-VIVO FEASIBILITY STUDY OF OPTICAL COHERENCE TOMOGRAPHY FOR AUTOMATED COLON POLYP CLASSIFICATION
    Thrapp, Andrew
    Photiou, Christos
    Villareyna-Lopez, Erica
    Chung, Anita
    Bhat, Nitasha
    Song, Du-Ri
    Lamphier, Genevieve
    Schulz-Hildebrandt, Hinnerk
    Caravaca-Mora, Oscar
    Murray, Miquela
    Miller, Tiffany
    Biddle, Elizabeth
    Yang, Ronald
    Chiavassa, Estelle
    Gregg, Abigail
    Jansa, Zachary
    Balmasheva, Indira
    Ryan, Emily
    Zoghbi, Sophia
    Grant, Catriona
    Nishioka, Norman
    Tearney, Guillermo
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (06) : AB740 - AB740
  • [28] OPTICAL COHERENCE TOMOGRAPHY OF THE PANCREATIC AND BILE DUCT: ARE WE READY FOR PRIME TIME?
    Tyberg, Amy
    Raijman, Isaac
    Novikov, Aleksey A.
    Sejpal, Divyesh V.
    Benias, Petros C.
    Trindade, Arvind J.
    Das, Ananya
    Sachdev, Mankanwal
    Khosravi, Farhoud
    Kedia, Prashant
    Gaidhane, Monica
    Kahaleh, Michel
    Joshi, Virendra
    GASTROENTEROLOGY, 2018, 154 (06) : S48 - S49
  • [29] Argon laser retinal lesions evaluated in vivo by optical coherence tomography
    Toth, CA
    Birngruber, R
    Boppart, SA
    Hee, MR
    Fujimoto, JG
    DiCarlo, CD
    Swanson, EA
    Cain, CP
    Narayan, DG
    Noojin, GD
    Roach, WP
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (02) : 188 - 198
  • [30] Ex vivo imaging of human thyroid pathology using integrated optical coherence tomography and optical coherence microscopy
    Zhou, Chao
    Wang, Yihong
    Aguirre, Aaron D.
    Tsai, Tsung-Han
    Cohen, David W.
    Connolly, James L.
    Fujimoto, James G.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)