Fabrication of Nanoporous Copper Film for Electrochemical Detection of Glucose

被引:59
|
作者
Sattayasamitsathit, Sirilak [1 ,2 ,3 ]
Thavarungkul, Panote [1 ,2 ,4 ]
Thammakhet, Chongdee [1 ,2 ,3 ]
Limbut, Warakorn [1 ,2 ,5 ]
Numnuam, Apon [1 ,2 ,3 ]
Buranachai, Chittanon [1 ,4 ]
Kanatharana, Proespichaya [1 ,2 ,3 ]
机构
[1] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Ctr Innovat Chem, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Fac Sci, Dept Gen Sci, Hat Yai 90112, Songkhla, Thailand
关键词
Electrodeposition; Porous copper electrode; Flow injection; Glucose detection; Chemical etching; Thin films; HIGH-SURFACE-AREA; CARBON NANOTUBE; PLATINUM; ELECTRODES; NICKEL; SYSTEM; ACIDS; CU;
D O I
10.1002/elan.200904697
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nanoporous copper film was fabricated oil a copper wire by electrodeposition of copper/zinc alloy and chemically etching of zinc. The surface morphology was investigated by SEM. When applied to detect glucose in an amperometric flow injection system the porous copper electrode provided 12 times higher sensitivity than solid copper. It could be continuously used LIP to 50 times (%RSD=5.7). Different preparations of the porous film provided reproducible responses (P < 0.05). Detection of glucose in E. coli cultivation medium compared well with spectrophotometric technique (P < 0.05). This simple technique can produce a nanoporous electrode with good performances and can easily be applied to other metals and analytes.
引用
收藏
页码:2371 / 2377
页数:7
相关论文
共 50 条
  • [21] Facile Fabrication of Nanoporous Gold Electrodes that Demonstrate High Electrochemical Activity and Used for Glucose Electrooxidation
    Li, Wenpeng
    Yu, Xiaohua
    Liu, Huiling
    Ji, Jingwei
    2013 INTERNATIONAL CONFERENCE ON MATERIALS FOR RENEWABLE ENERGY AND ENVIRONMENT (ICMREE), VOLS 1-3, 2013, : 433 - 435
  • [22] Electrochemical fabrication of nanoporous copper films in choline chloride-urea deep eutectic solvent
    Zhang, Q. B.
    Abbott, Andrew P.
    Yang, C.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2015, 17 (22) : 14702 - 14709
  • [23] Electrochemical fabrication of nanoporous polypyrrole thin films
    Li, Mei
    Yuan, Jinying
    Shi, Gaoquan
    THIN SOLID FILMS, 2008, 516 (12) : 3836 - 3840
  • [24] One step copper oxide (CuO) thin film deposition for non-enzymatic electrochemical glucose detection
    Inyang, Adijat
    Kibambo, Gloria
    Palmer, Maghmood
    Cummings, Franscious
    Masikini, Milua
    Sunday, Christopher
    Chowdhury, Mahabubur
    THIN SOLID FILMS, 2020, 709
  • [25] Functionalization of Carbon Nanotubes with Copper for Nonenzymatic Electrochemical Detection of Glucose
    Guo, Chang
    Wang, Lin
    Li, Maoguo
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2014, 6 (06) : 481 - 487
  • [26] Facile fabrication of nanoporous gold film electrodes
    Deng, Yanping
    Huang, Wei
    Chen, Xin
    Li, Zelin
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (05) : 810 - 813
  • [27] Low Cost Inkjet Fabrication of Glucose Electrochemical Sensors Based on Copper Oxide
    Bernasconi, R.
    Mangogna, A.
    Magagnin, L.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (08) : B3176 - B3183
  • [28] Cost-Effective and Fast Fabrication of Copper–Cobalt Electrochemical Glucose Sensor
    Aydan Zeynalova
    Kürşad Oğuz Oskay
    Journal of Electronic Materials, 2023, 52 : 6791 - 6799
  • [29] Facile Fabrication of a Graphene-based Electrochemical Biosensor for Glucose Detection
    Zhang Yanqin
    Fan Youjun
    Wang Shanshan
    Tan Yiliang
    Shen Xingcan
    Shi Zujin
    CHINESE JOURNAL OF CHEMISTRY, 2012, 30 (05) : 1163 - 1167
  • [30] Electrochemical Fabrication of Cobalt Oxides/Nanoporous Gold Composite Electrode and its Nonenzymatic Glucose Sensing Performance
    Zhou, Chaohui
    Tang, Xueyong
    Xia, Yue
    Li, Zelin
    ELECTROANALYSIS, 2016, 28 (09) : 2149 - 2157