Stability Augmentation of a Grid-Connected Wind Farm by Fuzzy-Logic-Controlled DFIG-Based Wind Turbines

被引:21
|
作者
Hazari, Md. Rifat [1 ]
Mannan, Mohammad Abdul [2 ]
Muyeen, S. M. [3 ]
Umemura, Atsushi [1 ]
Takahashi, Rion [1 ]
Tamura, Junji [1 ]
机构
[1] Kitami Inst Technol KIT, Dept Elect & Elect Engn, 165 Koen Cho, Kitami, Hokkaido 0908507, Japan
[2] Amer Int Univ Bangladesh AIUB, Dept Elect & Elect Engn, Ka 66-1,Kuratoli Rd, Dhaka 1229, Bangladesh
[3] Curtin Univ, Dept Elect & Comp Engn, Perth, WA 6845, Australia
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 01期
关键词
squirrel cage induction generator (SCIG); doubly fed induction generator (DFIG); fuzzy logic controller (FLC); PI controller; low voltage ride through (LVRT); power system; FAULT-RIDE; VOLTAGE; SYSTEMS; CROWBAR; SCHEME;
D O I
10.3390/app8010020
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Wind farm (WF) grid codes require wind generators to have low voltage ride through (LVRT) capability, which means that normal power production should be resumed quickly once the nominal grid voltage has been recovered. However, WFs with fixed-speed wind turbines with squirrel cage induction generators (FSWT-SCIGs) have failed to fulfill the LVRT requirement, which has a significant impact on power system stability. On the other hand, variable-speed wind turbines with doubly fed induction generators (VSWT-DFIGs) have sufficient LVRT augmentation capability and can control the active and reactive power delivered to the grid. However, the DFIG is more expensive than the SCIG due to its AC/DC/AC converter. Therefore, the combined use of SCIGs and DFIGs in a WF could be an effective solution. The design of the rotor-side converter (RSC) controller is crucial because the RSC controller contributes to the system stability. The cascaded control strategy based on four conventional PI controllers is widely used to control the RSC of the DFIG, which can inject only a small amount of reactive power during fault conditions. Therefore, the conventional strategy can stabilize the lower rating of the SCIG. In the present paper, a new control strategy based on fuzzy logic is proposed in the RSC controller of the DFIG in order to enhance the LVRT capability of the SCIG in a WF. The proposed fuzzy logic controller (FLC) is used to control the reactive power delivered to the grid during fault conditions. Moreover, reactive power injection can be increased in the proposed control strategy. Extensive simulations executed in the PSCAD/EMTDC environment for both the proposed and conventional PI controllers of the RSC of the DFIG reveal that the proposed control strategy can stabilize the higher rating of the SCIG.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Cooperative Rotor-Side SMES and Transient Control for Improving the LVRT Capability of Grid-Connected DFIG-Based Wind Farm
    Xiao, Xian-Yong
    Yang, Ruo-Huan
    Zheng, Zi-Xuan
    Wang, Ying
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)
  • [42] Improvement of Wind-Generator Stability by Fuzzy-Logic-Controlled SMES
    Ali, Mohd Hasan
    Park, Minwon
    Yu, In-Keun
    Murata, Toshiaki
    Tamura, Junji
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (03) : 1045 - 1051
  • [43] Modeling of a Droop-Controlled Grid-Connected DFIG Wind Turbine
    Oraa, Iker
    Samanes, Javier
    Lopez, Jesus
    Gubia, Eugenio
    IEEE ACCESS, 2022, 10 (6966-6977): : 6966 - 6977
  • [44] A simulation method of grid-connected wind farm on transient stability
    Han, Xiaoning
    Lei, Qiaohong
    Shi, Yan
    Han, Xiaoqing
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 955 - +
  • [45] Control strategy for suppressing the shafting oscillation of the grid-connected DFIG-based wind power generation system
    Yao, Jun
    Zhang, Tian
    Wang, Xuewei
    Zeng, Deyin
    Sun, Peng
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (09):
  • [46] Enhancement of the Flickermeter for Grid-Connected Wind Turbines
    Wang, Chau-Shing
    Yang, Wen-Ren
    Hsu, Yi-Cheng
    ENERGIES, 2021, 14 (18)
  • [47] PERFORMANCE ANALYSIS OF GRID-CONNECTED WIND TURBINES
    Duong, M. Q.
    Grimaccia, F.
    Leva, S.
    Mussetta, M.
    Sava, G.
    Costinas, S.
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2014, 76 (04): : 169 - 180
  • [48] Coupling DFIG-Based Wind Turbines with the Grid under Voltage Imbalance Conditions
    Sobhy, Ahmed
    Abo-Khalil, Ahmed G.
    Lei, Dong
    Salameh, Tareq
    Merabet, Adel
    Alkasrawi, Malek
    SUSTAINABILITY, 2022, 14 (09)
  • [49] Indirect Fuzzy Adaptive Synchronization and Control of a Grid-Connected DFIG-Based WECS
    Labdai, S.
    Alibi, A.
    Chrifi-Alaoui, L.
    Drid, S.
    Hemici, B.
    Nezli, L.
    2020 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND DIAGNOSIS (ICCAD), 2020, : 283 - 288
  • [50] Study of a Simplified Model for DFIG-Based Wind Turbines
    Lima, F. K. A.
    Luna, A.
    Rodriguez, P.
    Watanabe, E. H.
    Aredes, M.
    2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 749 - +