Stability Augmentation of a Grid-Connected Wind Farm by Fuzzy-Logic-Controlled DFIG-Based Wind Turbines

被引:21
|
作者
Hazari, Md. Rifat [1 ]
Mannan, Mohammad Abdul [2 ]
Muyeen, S. M. [3 ]
Umemura, Atsushi [1 ]
Takahashi, Rion [1 ]
Tamura, Junji [1 ]
机构
[1] Kitami Inst Technol KIT, Dept Elect & Elect Engn, 165 Koen Cho, Kitami, Hokkaido 0908507, Japan
[2] Amer Int Univ Bangladesh AIUB, Dept Elect & Elect Engn, Ka 66-1,Kuratoli Rd, Dhaka 1229, Bangladesh
[3] Curtin Univ, Dept Elect & Comp Engn, Perth, WA 6845, Australia
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 01期
关键词
squirrel cage induction generator (SCIG); doubly fed induction generator (DFIG); fuzzy logic controller (FLC); PI controller; low voltage ride through (LVRT); power system; FAULT-RIDE; VOLTAGE; SYSTEMS; CROWBAR; SCHEME;
D O I
10.3390/app8010020
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Wind farm (WF) grid codes require wind generators to have low voltage ride through (LVRT) capability, which means that normal power production should be resumed quickly once the nominal grid voltage has been recovered. However, WFs with fixed-speed wind turbines with squirrel cage induction generators (FSWT-SCIGs) have failed to fulfill the LVRT requirement, which has a significant impact on power system stability. On the other hand, variable-speed wind turbines with doubly fed induction generators (VSWT-DFIGs) have sufficient LVRT augmentation capability and can control the active and reactive power delivered to the grid. However, the DFIG is more expensive than the SCIG due to its AC/DC/AC converter. Therefore, the combined use of SCIGs and DFIGs in a WF could be an effective solution. The design of the rotor-side converter (RSC) controller is crucial because the RSC controller contributes to the system stability. The cascaded control strategy based on four conventional PI controllers is widely used to control the RSC of the DFIG, which can inject only a small amount of reactive power during fault conditions. Therefore, the conventional strategy can stabilize the lower rating of the SCIG. In the present paper, a new control strategy based on fuzzy logic is proposed in the RSC controller of the DFIG in order to enhance the LVRT capability of the SCIG in a WF. The proposed fuzzy logic controller (FLC) is used to control the reactive power delivered to the grid during fault conditions. Moreover, reactive power injection can be increased in the proposed control strategy. Extensive simulations executed in the PSCAD/EMTDC environment for both the proposed and conventional PI controllers of the RSC of the DFIG reveal that the proposed control strategy can stabilize the higher rating of the SCIG.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Fault Analysis of PI and Fuzzy-Logic-Controlled DFIG-based Grid-Connected Wind Energy Conversion System
    Ganthia B.P.
    Barik S.K.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (02) : 415 - 437
  • [2] Virtual Synchronous Control for Grid-Connected DFIG-Based Wind Turbines
    Wang, Shuo
    Hu, Jiabing
    Yuan, Xiaoming
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2015, 3 (04) : 932 - 944
  • [3] Virtual Synchronous Control of Grid-Connected DFIG-based Wind Turbines
    Zhao, Yangyang
    Chai, Jianyun
    Sun, Xudong
    2015 THIRTIETH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2015), 2015, : 2980 - 2983
  • [4] Stability Analysis for DFIG-Based Wind Farm Grid-Connected System Under All Wind Speed Conditions
    Du, Chengmao
    Du, Xiong
    Tong, Chenghui
    Li, Ying
    Zhou, Peipeng
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (02) : 2430 - 2445
  • [5] A Maximum Power Tracking Technique for Grid-Connected DFIG-Based Wind Turbines
    Fateh, Fariba
    White, Warren N.
    Gruenbacher, Don
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2015, 3 (04) : 957 - 966
  • [6] Analysis of Influencing Factors on Transient Voltage Stability of a Grid-connected DFIG-based Wind Farm
    Li, Sheng
    Ma, Ya-nan
    Cheng, Jie-lei
    Gong, Tian-tian
    Wang, Cheng
    2ND INTERNATIONAL CONFERENCE ON ENERGY AND POWER ENGINEERING (EPE 2018), 2018, : 212 - 216
  • [7] Modelling and comparison analysis of grid-connected DFIG-based wind farm in weak grid
    Yan, Cai
    Yao, Wei
    Wen, Jianfeng
    Fang, Jiakun
    Ai, Xiaomeng
    Wen, Jinyu
    IET RENEWABLE POWER GENERATION, 2020, 14 (13) : 2406 - 2415
  • [8] Experimental investigation of grid-connected operations for DFIG-based wind turbines with asymmetrical grid faults
    Zheng, Zhong
    Yang, Geng
    Geng, Hua
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2013, 53 (07): : 1036 - 1040
  • [9] Modeling of Grid-Connected DFIG-Based Wind Turbines for DC-Link Voltage Stability Analysis
    Hu, Jiabing
    Huang, Yunhui
    Wang, Dong
    Yuan, Hao
    Yuan, Xiaoming
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2015, 6 (04) : 1325 - 1336
  • [10] STABILITY ENHANCEMENT OF DFIG-BASED WIND FARM CONNECTED TO A GRID USING STATCOM
    Anzum
    Shankar, C. B.
    Prakash, R.
    2015 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2015,