Simultaneous Investigation of Entrained Liquid Fraction, Liquid Film Thickness and Pressure Drop in Vertical Annular Flow

被引:25
|
作者
Alamu, M. B. [1 ]
Azzopardi, B. J. [2 ]
机构
[1] Floxpat Petr & Energy Serv, London EC1V 4PW, England
[2] Univ Nottingham, Dept Chem Engn, Nottingham NG7 2RD, England
关键词
gas; liquid; drops; entrained fraction; void fraction; annular; PHASE DOPPLER; DIFFRACTION;
D O I
10.1115/1.4004265
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The mechanism of atomization of part of the liquid film to form drops in annular two-phase flow is not entirely understood. It has been observed that drop creation only occurs when there are large disturbance waves present on the film interface. (Woodmansee and Harrantty, 1969, "Mechanisms for the Removal of Droplets From a Liquid Surface by a Parallel Air Flow," Chem. Eng. Sci., 24, pp. 299-307) observed that ripples on these waves were precursors to drops. Though it has been reported that drops occur in bursts by (Azzopardi, Gas-Liquid Flows Begell House Inc., New York, 2006), all previous drop size or concentration measurements have always been time integrated to simplify data analysis. Dynamic time averaged drop size measurements are reported for the first time in annular flow. Experiments were carried out on a 19 mm internal diameter vertical pipe with air and water as fluids. Spraytec, a laser diffraction-based, drop size measurement instrument, was used in the drop related data acquisition. Simultaneous time-resolved measurements were carried out for drop, film thickness, and pressure drop. Film thickness has been measured using the conductance probes employing a pair of flush mounted rings as electrodes. Pressure drop was logged using differential pressure cell connected to two pressure taps located within the test section. The gas superficial velocity was varied systematically from 13 to 43 m/s at fixed liquid superficial velocities of 0.05 and 0.15 m/s, respectively. Additional tests were carried out with the gas velocity fixed at 14 m/s while the liquid superficial velocity was varied from 0.03 to 0.18 m/s. Signal acquired are presented in form of time series to permit data analysis at different levels. Based on signal analysis, interrelationships between liquid film where the drops are sourced and the contribution of the entrained liquid droplets to the overall pressure drop in the system has been elucidated. Though structures are not clearly visible in the signals acquired, the time series have been analyzed in amplitude space to yield probability density function (Pdf). Beyond gas superficial velocity of 30 m/s, Pdf of drop size distribution becomes monomodal or single-peaked marking transition to mist annular flow. [DOI:10.1115/1.4004265]
引用
收藏
页数:10
相关论文
共 50 条
  • [31] EFFECT OF ENTRAINMENT ON LIQUID FILM DRYOUT IN VERTICAL UPWARD ANNULAR FLOW
    Wu, Zan
    Wadekar, Vishwas
    Sunden, Bengt
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2016, VOL 2, 2016,
  • [32] Characteristics of refrigerant film thickness, pressure drop, and condensation heat transfer in annular flow
    Hurlburt, Evan T.
    Newell, Ty A.
    HVAC and R Research, 1999, 5 (03): : 229 - 248
  • [33] Characteristics of refrigerant film thickness, pressure drop, and condensation heat transfer in annular flow
    Hurlburt, ET
    Newell, TA
    HVAC&R RESEARCH, 1999, 5 (03): : 229 - 248
  • [34] Influence of Capillary Number on the droplet Shape, Film Thickness, and Pressure Drop in a Liquid-Liquid Taylor Flow inside a Microcapillary
    Vivekanand, S. V. B.
    Chandrasekhar, S.
    Raju, V. R. K.
    INTERNATIONAL JOURNAL OF MATHEMATICAL ENGINEERING AND MANAGEMENT SCIENCES, 2019, 4 (06) : 1407 - 1419
  • [36] Measurements of the liquid film thickness for annular flow during flow condensation in a circular tube
    Zhang, Yongxin
    Jia, Li
    Dang, Chao
    Qi, Zhuoling
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 187
  • [37] Annular two-phase flow in a C-shaped bend (flow of liquid drop entrained in gas core)
    Usui, Kensuke
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1993, 59 (560): : 1216 - 1221
  • [38] MEASUREMENT OF LIQUID FILM THICKNESS FOR ANNULAR TWO-PHASE HFC134A GAS-LIQUID ETHANOL FLOW IN THE VERTICAL TUBE
    Zhang, Huacheng
    Hisano, Tutomo
    Mori, Shoji
    Yoshida, Hiroyuki
    PROCEEDINGS OF 2021 28TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE28), VOL 4, 2021,
  • [39] Study on pressure drop characteristics of gas-liquid swirl annular flow
    Huo X.
    Xu Y.
    Wang J.
    Zhang T.
    Aikebaier M.
    Wang X.
    Huagong Xuebao/CIESC Journal, 2020, 71 (12): : 5506 - 5514
  • [40] HOLDUP AND PRESSURE DROP WITH GAS-LIQUID FLOW IN A VERTICAL PIPE
    HUGHMARK, GA
    PRESSBURG, BS
    AICHE JOURNAL, 1961, 7 (04) : 677 - 682