Effect of fretting amplitude and frequency on the fretting corrosion behaviour of tin plated contacts

被引:52
|
作者
Park, Young Woo [1 ]
Narayanan, T. S. N. Sankara [1 ]
Lee, Kang Yong [1 ]
机构
[1] Yonsei Univ, Sch Mech Engn, Stress Anal & Failure Design Lab, Seoul 120749, South Korea
来源
SURFACE & COATINGS TECHNOLOGY | 2006年 / 201卷 / 06期
关键词
fretting corrosion; tin plated contact; contact resistance; oxidation; surface characteristics;
D O I
10.1016/j.surfcoat.2006.03.031
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The fretting corrosion behaviour of tin plated copper alloy contacts at 3, 10 and 20 Hz and at two different track lengths (fretting amplitude) of +/- 5 and +/- 25 mu m is studied. The change in contact resistance as a function of fretting cycles, surface profile of the contact zone, extent of fretting damage, extent of oxidation and elemental distribution across the contact zone were used to assess the fretting corrosion behaviour. The time to reach a threshold value of contact resistance of 0.1 Omega is found to be early for the track length of +/- 5 mu m compared to that of +/- 25 mu m, at all the three frequencies. For a given track length, this threshold value reaches early at 20 Hz. The roughness and the nature of surface profile suggest considerable amount of oxidation have occurred at the track length of 25 pm compared to that of 5 gm. The surface morphology of the fretted zone reveals severe damage of the contact zone for samples with a track length of 25 lim at all the three frequencies. A pictorial model is proposed to describe the evolution of change in area of the contact zone. Based on the length and width of the contact zone, the fretted area is calculated. The change is fretted area as a function fretting frequency and track length is analyzed. Delamination wear is found to be operative at both track lengths and at all three frequencies. EDX line scanning also indicates higher levels of oxidation at the track length of +/- 25 mu m compared to that of 5 mu m. The variation in the atomic ratios of tin, copper and oxygen of the oxide debris present at the centre and edges of the fretted zone is plotted as an area plot as a function of experimental conditions. The debris is predominantly oxides of copper for the track length of +/- 25 mu m whereas they are mostly oxides of tin for the track length of +/- 5 mu m at all the three frequencies. The narrow and deep surface profile, lower R-a values, overlapping of the tin and copper lines in the EDX line scan and the predominance of oxides of tin support the view that the chances of accumulation of wear debris at the contact zone is very high at the track length of 5 gm. The study concludes that tin plated contacts could encounter an early failure even at shorter track lengths of +/- 5 mu m, if there is sufficient accumulation of the wear debris at the contact zone. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:2181 / 2192
页数:12
相关论文
共 50 条
  • [21] Three-Dimensional Structural Study of Tin Plated Fretting Contacts
    Ito, Tetsuya
    Nomura, Yoshiyuki
    Hattori, Yasuhiro
    PROCEEDINGS OF THE FIFTY-FIFTH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2009, : 316 - 320
  • [22] Observation of Tin Plated Fretting Contacts Using FIB-SEM
    Ito, Tetsuya
    Nomura, Yoshiyuki
    Hattori, Yasuhiro
    IEICE TRANSACTIONS ON ELECTRONICS, 2010, E93C (09): : 1452 - 1455
  • [23] Fretting wear behavior of tin plated contacts: Influence on contact resistance
    Park, Young Woo
    Narayanan, T. S. N. Sankara
    Lee, Kang Yong
    SURFACE REVIEW AND LETTERS, 2006, 13 (05) : 635 - 644
  • [24] Three-Dimensional Structural Transition of Tin Plated Fretting Contacts
    Ito, Tetsuya
    Ogihara, Shigeru
    Hattori, Yasuhiro
    PROCEEDINGS OF THE FIFTY-SIXTH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2010, : 303 - 308
  • [25] Fretting behavior of gold plated contacts
    Lin, Xueyan
    Proceedings of the 2nd International Conference on Reliability of Electrical Products and Electrical Contacts, 2007, : 178 - 182
  • [26] Development of empirical equations for fretting-corrosion failure-time of tin-plated contacts
    Park, Young Woo
    Lee, Kang Yong
    WEAR, 2008, 265 (5-6) : 756 - 762
  • [27] Fretting effect on gold-plated and tin-plated surfaces
    Shao, Chunbo
    Zhang, Jigao
    Beijing Youdian Xueyuan Xuebao/Journal of Beijing University of Posts And Telecommunications, 1998, 21 (02): : 23 - 27
  • [28] Effect of normal forces on fretting corrosion of tin-coated electrical contacts
    Han, Dong-Woon
    Kim, Ho-Kyung
    MICROELECTRONICS RELIABILITY, 2017, 79 : 321 - 327
  • [29] Simulation for fretting corrosion of tin-coated copper contacts
    Lee, K. Y.
    Jeong, D. K.
    Joo, H. G.
    Park, Y. W.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2011, 62 (04): : 352 - 356
  • [30] Fretting behaviour of TiN coating
    Wei, J
    Fouvry, S
    Kapsa, P
    Vincent, L
    SURFACE MODIFICATION TECHNOLOGIES X, 1997, : 24 - 36