A compensation method for solid concentration through measurement of water content with capacitance sensors in gas-solid flow

被引:0
|
作者
Zhan Ming [1 ]
Liu Kejin [1 ]
Meng Lingjun [1 ]
Dong Hongguang [1 ]
Guo Baogui [1 ]
机构
[1] Northeastern Univ, Sch Informat Sci & Engn, Shenyang 110004, Peoples R China
关键词
capacitance transducer; two-phase flow of solid/gas;
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The moisture content has great effect on capacitance transducer for measuring concentration of two-phase flow of solid/gas. The paper describes an method of correction the error caused by moisture content in capacitance transducer by designing feedback parameters specially. The experimental results showed when variation of moisture content between 0.5%-2%. The measurement error of the concentration of two-phase flow of solid-gas could be restrain below 5%.
引用
收藏
页码:167 / 169
页数:3
相关论文
共 50 条
  • [21] Development of ring-shaped electrostatic coupled capacitance sensor for the parameter measurement of gas-solid flow
    Ding, Hui
    Li, Jian
    Wang, Haoran
    Xu, Chuanlong
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2021, 43 (11) : 2567 - 2576
  • [22] Solid concentration distribution in a gas-solid fluidized bed
    Engineering Research Center of Large Scale Reactor Engineering and Technology, East China University of Science and Technology, Shanghai 200237, China
    不详
    不详
    Guocheng Gongcheng Xuebao, 2008, 5 (839-844):
  • [23] Measurement of Gas-solid Flow Pattern in Rectangle Cross-section in CFB by Electrical Capacitance Tomography
    Li, Jingji
    Wang, Wei
    Yang, Hairui
    Zhang, Hai
    Liu, Qing
    CLEANER COMBUSTION AND SUSTAINABLE WORLD, 2012, : 396 - 399
  • [24] Particle Size Measurement in Gas-Solid Two-Phase Flow Using Acoustic Sensors
    Guo, Miao
    Yan, Yong
    Hua, Yonghui
    Sun, Duo
    Qian, Xiangcheng
    Han, Xiaojuan
    8TH INTERNATIONAL SYMPOSIUM ON MEASUREMENT TECHNIQUES FOR MULTIPHASE FLOWS, 2014, 1592 : 302 - 308
  • [26] Concentration and viscosity of solid phase in a fully developed dilute gas-solid vertical flow
    Ding, Yulong
    Cang, Daqiang
    Yang, Tianjun
    Beijing Keji Daxue Xuebao/Journal of University of Science and Technology Beijing, 1994, 16 (01):
  • [27] Application of γ-ray attenuation technology in measurement of solid concentration of gas-solid two-phase flow in a FCC riser
    Tan, Hong-Tao
    Dong, Gan-Guo
    Wei, Yao-Dong
    Shi, Ming-Xian
    Guocheng Gongcheng Xuebao/The Chinese Journal of Process Engineering, 2007, 7 (05): : 895 - 899
  • [28] Thermodynamics of gas-solid flow
    Collado, FJ
    Sevilla, E
    Valcárcel, C
    AICHE JOURNAL, 2002, 48 (05) : 1100 - 1108
  • [29] On parameter measurement of gas-solid fluidized bed based on electrical capacitance tomography
    Wang Lei
    Shen Tao
    Proceedings of 2005 Chinese Control and Decision Conference, Vols 1 and 2, 2005, : 591 - 593
  • [30] Evaluation of the Performance of Capacitance Sensor for Concentration Measurement of Gas/Solid Particles Flow by Coupled Fields
    Wang, Xiaoxin
    Hu, Yizhi
    Hu, Hongli
    Li, Lin
    IEEE SENSORS JOURNAL, 2017, 17 (12) : 3754 - 3764