A plastic scintillation dosimeter for high dose rate brachytherapy

被引:106
|
作者
Lambert, J. [1 ]
McKenzie, D. R.
Law, S.
Elsey, J.
Suchowerska, N.
机构
[1] Univ Sydney, Sch Phys, Sydney, NSW 2006, Australia
[2] Royal Prince Alfred Hosp, Dept Radiat Oncol, Camperdown, NSW 2050, Australia
[3] Univ Sydney, Opt Fibre Technol Ctr, Eveleigh, NSW 1430, Australia
[4] Bandwidth Foundry Pty Ltd, Eveleigh, NSW 1430, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 21期
关键词
D O I
10.1088/0031-9155/51/21/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vivo dose verification in brachytherapy requires a small insertable dosimeter with a real-time readout capability. Fibre optic scintillation dosimeters, consisting of a plastic scintillator coupled to an optical fibre, are one of the most promising dosimeters for this application. We have developed two sizes of the BrachyFOD (TM) scintillation dosimeter which have external diameters of 2.2 mm and 1 mm and have determined their important dosimetric characteristics ( depth dose relation, angular dependence, temperature dependence, energy dependence). We have shown that the background signal created by Cerenkov and fibre fluorescence does not significantly affect the performance in most clinical geometries using an Ir-192 source from an HDR brachytherapy unit. The dosimeter design enables readout at less than 0.5 s intervals. The BrachyFOD (TM) satisfies the need for a real-time in vivo brachytherapy dosimeter.
引用
收藏
页码:5505 / 5516
页数:12
相关论文
共 50 条
  • [41] High dose rate brachytherapy for prostate cancer
    Hoskin, P.
    CANCER RADIOTHERAPIE, 2008, 12 (6-7): : 512 - 514
  • [42] High dose rate brachytherapy of the base of tongue
    Takácsi-Nagy, Z
    Oberna, F
    Somogyi, A
    Major, T
    Polgár, C
    Németh, G
    EUROPEAN JOURNAL OF CANCER, 1999, 35 : S178 - S178
  • [43] High dose rate brachytherapy for gynecologic neoplasms
    Petereit, DG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 104 - 104
  • [44] MUSCLE AND PLASTIC EQUIVALENT GLASS DOSIMETER FOR HIGH-DOSE DOSIMETRY
    ABDELREHIM, F
    MAGED, AF
    MORSY, MA
    HASHAD, AM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1990, 140 (01): : 103 - 110
  • [45] Dose distribution verification in high-dose-rate brachytherapy using a highly sensitive normoxic N-vinylpyrrolidone polymer gel dosimeter
    Watanabe, Yusuke
    Mizukami, Shinya
    Eguchi, Kou
    Maeyama, Takuya
    Hayashi, Shin-ichiro
    Muraishi, Hiroshi
    Terazaki, Tsuyoshi
    Gomi, Tsutomu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 72 - 79
  • [46] Verification of dose distribution in high dose-rate brachytherapy for cervical cancer using a normoxic N-vinylpyrrolidone polymer gel dosimeter
    Watanabe, Yusuke
    Maeyama, Takuya
    Mizukami, Shinya
    Tachibana, Hidenobu
    Terazaki, Tsuyoshi
    Takei, Hideyuki
    Muraishi, Hiroshi
    Gomi, Tsutomu
    Hayashi, Shin-ichiro
    JOURNAL OF RADIATION RESEARCH, 2022, 63 (06) : 838 - 848
  • [47] Plastic Scintillation Detector for Dosimetric Characterization of Mobetron Ultra-High Dose Rate Electron Beam
    Famulari, G.
    Zerouali, K.
    Piron, O.
    Aubry, J.
    DeBlois, F.
    Carrier, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E539 - E540
  • [48] Sigmoid dose delivered by high-dose-rate brachytherapy versus low-dose-rate brachytherapy for cervical cancer
    Holloway, C. L.
    O'Farrell, D. A.
    Cormack, R. A.
    Viswanathan, A. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S165 - S165
  • [49] Toward 3D dose verification of an electronic brachytherapy source with a plastic scintillation detector
    Georgi, Peter
    Kertzscher, Gustavo
    Nyvang, Lars
    Solc, Jaroslav
    Schneider, Thorsten
    Tanderup, Kari
    Johansen, Jacob Graversen
    MEDICAL PHYSICS, 2022, 49 (05) : 3432 - 3443
  • [50] Accurate calibration of a polymer gel dosimeter with a plastic scintillation detector
    Tremblay, Nicolas M.
    Hubert-Tremblay, Vincent
    Bujold, Rachel
    Beddar, A. Sam
    Beaulieu, Luc
    Lepage, Martin
    MEDICAL PHYSICS, 2011, 38 (05) : 2754 - 2761