Selenium-based digital radiography versus conventional film-screen radiography of the hands and feet: A subjective comparison

被引:26
|
作者
Piraino, DW [1 ]
Davros, WJ [1 ]
Lieber, M [1 ]
Richmond, BJ [1 ]
Schils, JP [1 ]
Recht, MP [1 ]
Grooff, PN [1 ]
Belhobek, GH [1 ]
机构
[1] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
关键词
D O I
10.2214/ajr.172.1.9888764
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to subjectively compare the visibility of normal anatomy of the hands and feet using selenium-based digital radiography versus conventional film-screen (100-speed) radiography. SUBJECTS AND METHODS. Digital and film-screen images of the hands and feet of 24 patients were obtained without an antiscatter grid using identical X-ray exposure. Each pair of images was evaluated independently by five experienced radiologists for visibility of normal anatomy using a six-point rating scale. Soft tissues, cortical bone, and trabeculae were evaluated. For each observer, "equivalence" was defined as a mean difference in image quality of less than 1 unit on the 0-5 scale used in the study. Paired t tests were also performed to determine whether the average visibility rating of one technique was statistically superior to that of the other at a .05 level of significance for each observer and at each anatomic landmark. RESULTS. In all categories, selenium-based digital images were rated equivalent to film-screen images by the five observers. Using the sum of the nine landmarks, four of the ve observers rated the quality of selenium-based digital images superior to that of film-screen images. CONCLUSION. Subjective visibility of normal anatomy of the hands and feet using selenium-based digital radiography was similar to that achieved using conventional film-screen radiography.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 50 条
  • [11] COMPARISON OF DIGITAL LUMINESCENCE RADIOGRAPHY (DLR) AND CONVENTIONAL FILM-SCREEN SYSTEM COMBINATIONS IN SIALOGRAPHIES
    KRUG, B
    FRIEDMANN, G
    STEINBRICH, W
    LOENNECKEN, I
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1989, 150 (06): : 718 - 722
  • [12] Comparison of selenium-based digital and conventional screen-film chest radiography in the depiction of normal anatomy and CT-proved pathology
    Woodard, PK
    Slone, RM
    Gierada, DS
    Reiker, GG
    Jost, RG
    RADIOLOGY, 1996, 201 : 1468 - 1468
  • [13] Comparative reject analysis in conventional film-screen and digital storage phosphor radiography
    S. Peer
    R. Peer
    M. Walcher
    M. Pohl
    W. Jaschke
    European Radiology, 1999, 9 : 1693 - 1696
  • [14] Comparison of Digital Direct Readout Radiography with Conventional Film-screen Radiography for the Recognition of Pneumoconiosis in Dust-exposed Chinese Workers
    Mao, Ling
    Laney, A. Scott
    Wang, Mei Lin
    Sun, Xiwen
    Zhou, Shaowei
    Shi, Jin
    Shi, Haiyan
    JOURNAL OF OCCUPATIONAL HEALTH, 2011, 53 (05) : 320 - 326
  • [15] Comparative reject analysis in conventional film-screen and digital storage phosphor radiography
    Peer, S
    Peer, R
    Walcher, M
    Pohl, M
    Jaschke, W
    EUROPEAN RADIOLOGY, 1999, 9 (08) : 1693 - 1696
  • [16] Comparative reject analysis in conventional film-screen and digital storage phosphor radiography
    Peer, S
    Peer, R
    Giacomuzzi, SM
    Jaschke, W
    DOSE AND IMAGE QUALITY IN DIGITAL IMAGING AND INTERVENTIONAL RADIOLOGY (DIMOND), 2001, : 69 - 71
  • [17] Comparative reject analysis in conventional film-screen and digital storage phosphor radiography
    Peer, S
    Peer, R
    Giacomuzzi, SM
    Jaschke, W
    RADIATION PROTECTION DOSIMETRY, 2001, 94 (1-2) : 69 - 71
  • [18] Applications of selenium-based alloys for digital radiography
    LEcuyer, J
    Mouton, A
    Legros, A
    Selmani, A
    Currie, J
    Degtorov, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 493 - 496
  • [19] Improved contrast-detail detection with flat-panel digital radiography: Comparison with computed radiography and a conventional film-screen system
    Erb, G
    Aretz, K
    Hahmann, M
    Radeleff, BA
    Hansmann, J
    Kauffmann, GW
    RADIOLOGY, 2000, 217 : 164 - 164
  • [20] COMPARISON OF COMPUTERIZED DIGITAL AND FILM-SCREEN RADIOGRAPHY - RESPONSE TO VARIATION IN IMAGING KVP
    BRODERICK, NJ
    LONG, B
    DREESEN, RG
    COHEN, MD
    CORY, DA
    KATZ, BP
    KALASINSKI, LA
    PEDIATRIC RADIOLOGY, 1992, 22 (05) : 346 - 349