First successful transapical aortic valve implantation with the Corevalve Revalving™ System:: A case report

被引:33
|
作者
Lange, Ruediger [1 ]
Schreiber, Christian [1 ]
Goetz, Wolfgang [1 ]
Hettich, Ina [1 ]
Will, Albrecht [2 ]
Libera, Paul [1 ]
laborde, Jean-Claude [3 ]
Bauernschmitt, Robert [1 ]
机构
[1] Tech Univ, Cardiovasc Surg Clin, German Heart Ctr, D-80636 Munich, Germany
[2] Tech Univ, Dept Radiol & Nucl Med, German Heart Ctr, D-80636 Munich, Germany
[3] Clin Pasteur, Dept Cardiol, Toulouse, France
来源
HEART SURGERY FORUM | 2007年 / 10卷 / 06期
关键词
D O I
10.1532/HSF98.20071140
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
On June 26, 2007, the Clinic for Cardiovascular Surgery at the German Heart Center Technical University in Munich successfully implanted a bioprosthetic valve via the apex of the heart within the framework of the CoreValve TAVR ReValving (Corevalve Inc., Irvine, CA, USA) clinical trial. The self-expanding aortic valve prosthesis is primarily designed for retrograde delivery across the aortic valve. The described transapical approach, however, now allows for treatment in those patients who have, for instance, no adequate "access" in the groin vessels due to peripheral vascular disease. Therefore, its feasibility must be considered as a major step in treating high-risk patients.
引用
收藏
页码:E478 / E479
页数:2
相关论文
共 50 条
  • [31] Study of conformability of Corevalve Revalving System® away from implantation
    Ancion, Arnaud
    Legrand, Victor
    ACTA CARDIOLOGICA, 2012, 67 (01) : 127 - 128
  • [32] Implantation of the CoreValve percutaneous aortic valve
    Lamarche, Yoan
    Cartier, Raymond
    Denault, Andre Y.
    Basmadjian, Arsene
    Berry, Colin
    Laborde, Jean-Claude
    Bonan, Raoul
    ANNALS OF THORACIC SURGERY, 2007, 83 (01): : 284 - 287
  • [33] Transfemoral Treatment of Bioprosthetic Aortic Valve Failure-Suitability of the Medtronic CoreValve ReValving System
    Woitek, Felix J.
    Schiefer, Conrad
    Sofianos, Georgios
    Mangner, Norman
    Merx, Marc
    Walther, Thomas
    Mohr, Friedrich W.
    Kelm, Malte
    Schuler, Gerhard C.
    Linke, Axel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B36 - B36
  • [34] Expanding the Eligibility for Transcatheter Aortic Valve Implantation The Trans-Subclavian Retrograde Approach Using the III Generation CoreValve Revalving System
    Fraccaro, Chiara
    Napodano, Massimo
    Tarantini, Giuseppe
    Gasparetto, Valeria
    Gerosa, Gino
    Bianco, Roberto
    Bonato, Raffaele
    Pittarello, Demetrio
    Isabella, Giambattista
    Iliceto, Sabino
    Ramondo, Angelo
    JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) : 828 - 833
  • [35] Transapical aortic valve implantation in humans
    Ye, J
    Cheung, AS
    Lichtenstein, SV
    Carere, RG
    Thompson, CR
    Pasupati, S
    Webb, JG
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (05): : 1194 - 1196
  • [36] Awake transapical aortic valve implantation
    Petridis, Francesco Dimitri
    Savini, Carlo
    Castelli, Andrea
    Di Bartolomeo, Roberto
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (05) : 673 - 674
  • [37] Transapical Transcatheter Aortic Valve Implantation with the J-Valve System in Aortic Regurgitation
    Zhu, Pengxiong
    Li, Jinping
    Xue, Bangde
    Huang, Jing
    Ling, Yun
    Zhang, Qi
    Liu, Jun
    CJC OPEN, 2025, 7 (02) : 145 - 152
  • [38] Minimally transapical aortic valve implantation
    Kempfert, J.
    Walther, T.
    Borger, M. A.
    Falk, V
    Blumenstein, J.
    Fassl, J.
    Lehmann, S.
    Holzhey, D.
    Schuler, G.
    Mohr, E. W.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2007, 21 (04): : 170 - 178
  • [39] Successful Percutaneous Coronary Intervention After Implantation of a CoreValve Percutaneous Aortic Valve
    Geist, Volker
    Sherif, Mohammad A.
    Khattab, Ahmed A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (01) : 61 - 67
  • [40] Transapical transcatheter aortic valve implantation
    Beyersdorf, Friedhelm