The Mid-Infrared Instrument for the James Webb Space Telescope, VII: The MIRI Detectors

被引:79
|
作者
Rieke, G. H. [1 ]
Ressler, M. E. [2 ]
Morrison, Jane E. [1 ]
Bergeron, L. [3 ]
Bouchet, Patrice [4 ]
Garcia-Marin, Macarena [5 ]
Greene, T. P. [6 ]
Regan, M. W. [3 ]
Sukhatme, K. G. [2 ]
Walker, Helen [7 ]
机构
[1] Univ Arizona, Steward Observ, Tucson, AZ 85721 USA
[2] CALTECH, Jet Prop Lab, Pasadena, CA 91109 USA
[3] Space Telescope Sci Inst, Baltimore, MD 21218 USA
[4] Univ Paris Diderot, Lab AIM Paris Saclay, CNRS, CEA,IRFU,SAp, F-91191 Gif Sur Yvette, France
[5] Univ Cologne, Inst Phys 1, D-50937 Cologne, Germany
[6] NASA, Ames Res Ctr, Moffett Field, CA 94035 USA
[7] Rutherford Appleton Lab, RALSpace, STFC, Didcot OX11 0QX, Oxon, England
关键词
ARRAY-CAMERA IRAC; MULTIBAND IMAGING PHOTOMETER; IN-FLIGHT PERFORMANCE; FOCAL-PLANE ARRAYS; REDUCTION ALGORITHMS; SPITZER; CALIBRATION;
D O I
10.1086/682257
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The MIRI Si: As IBC detector arrays extend the heritage technology from the Spitzer IRAC arrays to a 1024 x 1024 pixel format. We provide a short discussion of the principles of operation, design, and performance of the individual MIRI detectors, in support of a description of their operation in arrays provided in an accompanying paper. We then describe modeling of their response. We find that electron diffusion is an important component of their performance, although it was omitted in previous models. Our new model will let us optimize the bias voltage while avoiding avalanche gain. It also predicts the fraction of the IR-active layer that is depleted (and thus contributes to the quantum efficiency) as signal is accumulated on the array amplifier. Another set of models accurately predicts the nonlinearity of the detector-amplifier unit and has guided determination of the corrections for nonlinearity. Finally, we discuss how diffraction at the interpixel gaps and total internal reflection can produce the extended cross-like artifacts around images with these arrays at short wavelengths, similar to 5 mu m. The modeling of the behavior of these devices is helping optimize how we operate them and also providing inputs to the development of the data pipeline.
引用
收藏
页码:665 / 674
页数:10
相关论文
共 50 条
  • [31] Feasibility of the four-quadrant phase mask in the mid-infrared on the James!Webb Space Telescope
    Baudoz, P
    Boccaletti, A
    Riaud, P
    Cavarroc, C
    Baudrand, J
    Reess, JM
    Rouan, D
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2006, 118 (843) : 765 - 773
  • [32] James Webb Space Telescope MIRI Shear Pupil Analysis
    Wright, Raymond H.
    Sabatke, Derek
    Telfer, Randal
    SPACE TELESCOPES AND INSTRUMENTATION 2022: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2022, 12180
  • [33] Detectors for the James!Webb Space Telescope Near Infrared Spectrograph (NIRSpec)
    Rauscher, Bernard J.
    Boker, Torsten
    Cabelli, Craig
    De Marchi, Guido
    Ferruit, Pierre
    Garnett, James
    Hill, Robert J.
    Loose, Markus
    Regan, Michael W.
    Waczynski, Augustyn
    Wen, Yiting
    Wong, Selmer
    Zandian, Majid
    Alexander, David
    Brambora, Clifford K.
    Derro, Rebecca
    Dunn, Carol
    Ellis, Timothy
    Garrison, Matthew B.
    Howe, Bryan
    Jakobsen, Peter
    Johnson, Thomas E.
    Jurado, Miriam
    Lee, Ginn
    Manthripragada, Sridhar S.
    Marsh, James M.
    Marshall, Cheryl
    Martineau, Robert J.
    Mott, Brent
    Nieznanski, John
    Roher, Wayne D.
    Shakoorzadeh, Kamdin B.
    Smith, Miles T.
    Strada, Paolo
    Wallis, Peter
    Wei Xia-Serafino
    York, James
    SPACE TELESCOPES AND INSTRUMENTATION I: OPTICAL, INFRARED, AND MILLIMETER, PTS 1 AND 2, 2006, 6265
  • [34] Detectors for the James Webb Space Telescope near-infrared spectrograph
    Rauscher, BJ
    Figer, DF
    Regan, MW
    Böker, T
    Garnett, J
    Hill, RJ
    Bagnasco, G
    Balleza, J
    Barney, R
    Bergeron, LE
    Brambera, C
    Connelly, J
    Derro, R
    DiPirro, M
    Doria-Warner, C
    Ericsson, A
    Glazer, S
    Greene, C
    Hall, DNB
    Jacobson, S
    Jakobsen, P
    Johnson, E
    Johnson, SD
    Krebs, C
    Krebs, DJ
    Lambros, S
    Likins, B
    Manthripragada, S
    Martineau, RJ
    Morse, E
    Moseley, SH
    Mott, DB
    Muench, T
    Park, H
    Parker, S
    Polidan, E
    Rashford, R
    Shakoorzadeh, K
    Sharma, R
    Strada, P
    Waczynski, A
    Wen, YT
    Wong, S
    Yagelowich, J
    Zuray, M
    OPTICAL, INFRARED, AND MILLIMETER SPACE TELESCOPES, PTS 1-3, 2004, 5487 : 710 - 726
  • [35] Detectors for the James Webb Space Telescope near-infrared spectrograph
    Rauscher, Bernard J.
    Figer, Donald F.
    Regan, Michael W.
    Böker, Torsten
    Garnett, James
    Hill, Robert J.
    Bagnasco, Georgio
    Balleza, Jesus
    Barney, Richard
    Bergeron, Louis E.
    Brambora, Clifford
    Connelly, Joe
    Derro, Rebecca
    DiPirro, Mike
    Doria-Warner, Cristina
    Ericsson, Aprille
    Glazer, Stu
    Greene, Charles
    Hall, Donald N.B.
    Jacobson, Shane
    Jakobsen, Peter
    Johnson, Eric
    Johnson, Scott D.
    Krebs, Carolyn
    Krebs, Danny J.
    Lambros, Scott
    Likins, Blake
    Manthripragada, Sridhar
    Martineau, Robert J.
    Morse, Ernie
    Moseley, S. Harvey
    Mott, D. Brent
    Muench, Theo
    Park, Hongwoo
    Parker, Susan
    Polidan, Elizabeth
    Rashford, Robert
    Shakoorzadeh, Kamdin
    Sharma, Raveev
    Strada, Paolo
    Waczynski, Augustyn
    Wen, Yiting
    Wong, Selmner
    Yagelowich, John
    Zuray, Monica
    Proc SPIE Int Soc Opt Eng, 1600, PART 2 (710-726):
  • [36] The MIRI medium resolution spectrometer for the James Webb Space Telescope
    Wells, M.
    Lee, D.
    Oudenhuysen, A.
    Hastings, P.
    Pel, J-W.
    Glasse, A.
    SPACE TELESCOPES AND INSTRUMENTATION I: OPTICAL, INFRARED, AND MILLIMETER, PTS 1 AND 2, 2006, 6265
  • [37] Development and test programme of the wheel mechanisms for the Mid Infra-Red Instrument (MIRI) of the James Webb Space Telescope (JWST)
    Hofferbert, R
    Lemke, D
    Böhm, A
    de Bonis, F
    Ebert, M
    Grözinger, U
    Henning, T
    Huber, A
    Kuhlmann, S
    Ramos, J
    Rohloff, RR
    11TH EUROPEAN SPACE MECHANISMS AND TRIBOLOGY SYMPOSIUM, PROCEEDINGS, 2005, 591 : 107 - 114
  • [38] Manufacturing and measurement of the MIRI spectrometer optics for the James Webb Space Telescope
    Shore, P.
    Morantz, P.
    Lee, D.
    CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2006, 55 (01) : 543 - 546
  • [39] Cryomechanisms for the instruments MIRI and NIRSpec on the James Webb Space Telescope (JWST)
    Hofferbert, R
    Lemke, D
    Grözinger, U
    Henning, T
    Mertin, S
    Rohloff, RR
    Wagner, K
    Wright, GS
    Visser, H
    INFRARED SPACEBORNE REMOTE SENSING XI, 2003, 5152 : 70 - 82
  • [40] The Mechanical Design of a Kinematic Mount for the Mid Infrared Instrument Focal Plane Module on the James Webb Space Telescope
    Thelen, Michael P.
    Moore, Donald M.
    2009 IEEE AEROSPACE CONFERENCE, VOLS 1-7, 2009, : 1390 - 1396