Electrospin-coating of nitrocellulose membrane enhances sensitivity in nucleic acid-based lateral flow assay

被引:57
|
作者
Yew, Chee-Hong Takahiro [1 ,2 ]
Azari, Pedram [1 ,3 ]
Choi, Jane Ru [4 ]
Li, Fei [2 ,5 ]
Pingguan-Murphy, Belinda [1 ,6 ]
机构
[1] Univ Malaya, Dept Biomed Engn, Fac Engn, Kuala Lumpur 50603, Malaysia
[2] Xi An Jiao Tong Univ, BEBC, Xian 710049, Shaanxi, Peoples R China
[3] Univ Malaya, Dept Biomed Engn, Ctr Appl Biomech, Fac Engn, Kuala Lumpur 50603, Malaysia
[4] Univ British Columbia, Dept Mech Engn, 2054-6250 Appl Sci Lane, Vancouver, BC V6T 1Z4, Canada
[5] Xi An Jiao Tong Univ, Sch Life Sci & Technol, Minist Educ, Key Lab Biomed Informat Engn, Xian 710049, Shaanxi, Peoples R China
[6] Univ Malaya, Ctr Initiat Talent & Ind Training CITra, Kuala Lumpur 50603, Malaysia
关键词
Point-of-care; Paper-based biosensor; Nucleic acid testing; Electrospinning; Polycaprolactone; Nitrocellulose; POINT; IMMUNOASSAY; BIOSENSOR; INFECTION; NANOFIBER;
D O I
10.1016/j.aca.2018.01.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Point-of-care biosensors are important tools developed to aid medical diagnosis and testing, food safety and environmental monitoring. Paper-based biosensors, especially nucleic acid-based lateral flow assays (LFA), are affordable, simple to produce and easy to use in remote settings. However, the sensitivity of such assays to infectious diseases has always been a restrictive challenge. Here, we have successfully electrospun polycaprolactone (PCL) on nitrocellulose (NC) membrane to form a hydrophobic coating to reduce the flow rate and increase the interaction rate between the targets and gold nanoparticles-detecting probes conjugates, resulting in the binding of more complexes to the capture probes. With this approach, the sensitivity of the PCL electrospin-coated test strip has been increased by approximately ten-fold as compared to the unmodified test strip. As a proof of concept, this approach holds great potential for sensitive detection of targets at point-of-care testing. (c) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [21] Framework nucleic acid-based nanoparticles enhance temozolomide sensitivity in glioblastoma
    Lan, Yufei
    Li, Xiaodie
    Liu, Boyang
    Lu, Jiankun
    Zuo, Boming
    Wang, Yue
    Cao, Shuting
    Fu, Xin
    Yue, Qu
    Luo, Xin
    Zhong, Xiangyang
    Dong, Yaoyuan
    Wang, Zhao
    Yang, Tao
    Xie, Xinyun
    Zeng, Tianci
    Zhang, Manqing
    Wang, Yuankai
    Shen, Yixiong
    Zuo, Huaqin
    Zhao, Yan
    Zhang, Chao
    Guo, Hongbo
    DRUG RESISTANCE UPDATES, 2024, 76
  • [22] Mechanically Compressed Barriers Improve Paper-Based Lateral Flow Assay Sensitivity for COVID-19 Nucleic Acid Detection
    Alam, Nur
    Tong, Li
    He, Zhibin
    Tang, Ruihua
    Ahsan, Laboni
    Ni, Yonghao
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (44) : 18800 - 18809
  • [23] A Review of the Nucleic Acid-Based Lateral Flow Assay for Detection of Breast Cancer from Circulating Biomarkers at a Point-of-Care in Low Income Countries
    Dyan, Busiswa
    Seele, Palesa Pamela
    Skepu, Amanda
    Mdluli, Phumlane Selby
    Mosebi, Salerwe
    Sibuyi, Nicole Remaliah Samantha
    DIAGNOSTICS, 2022, 12 (08)
  • [24] A new colorimetric peptide nucleic acid-based assay for the specific detection of bacteria
    Almeida, Carina
    Constante, Diogo
    Ferreira, Andre
    Cerqueira, Laura
    Vieira, Maria J.
    Azevedo, Nuno F.
    FUTURE MICROBIOLOGY, 2014, 9 (10) : 1131 - 1142
  • [25] Nucleic acid lateral flow assay for simultaneous detection of hygiene indicator bacteria
    Ji Min Kim
    Jung Soo Park
    Tae Hwi Yoon
    Junghun Park
    Ki Soo Park
    Analytical and Bioanalytical Chemistry, 2021, 413 : 5003 - 5011
  • [26] Comparative Study of Gold and Carbon Nanoparticles in Nucleic Acid Lateral Flow Assay
    Carlos Porras, Juan
    Bernuz, Mireia
    Marfa, Jennifer
    Pallares-Rusinol, Arnau
    Marti, Merce
    Isabel Pividori, Maria
    NANOMATERIALS, 2021, 11 (03) : 1 - 11
  • [27] Nucleic acid lateral flow assay for simultaneous detection of hygiene indicator bacteria
    Kim, Ji Min
    Park, Jung Soo
    Yoon, Tae Hwi
    Park, Junghun
    Park, Ki Soo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (20) : 5003 - 5011
  • [28] Nucleic Acid-Based Lateral Flow Biosensor for Salmonella Typhi and Salmonella Paratyphi: A Detection in Stool Samples of Suspected Carriers
    Amalina, Zulkiply Nor
    Khalid, Muhammad Fazli
    Rahman, Sjafri Faizul
    Ahmad, Muhamad Nuramin
    Najib, Mohamad Ahmad
    Ismail, Asma
    Aziah, Ismail
    DIAGNOSTICS, 2021, 11 (04)
  • [29] Rapid detection of methicillin-resistant Staphylococcus aureus in pork using a nucleic acid-based lateral flow immunoassay
    Ma, Luyao
    Zhang, Hongwei
    Ma, Lina
    Hua, Zhong
    Wang, Shuo
    Lu, Xiaonan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [30] Rapid detection of methicillin-resistant Staphylococcus aureus in pork using a nucleic acid-based lateral flow immunoassay
    Zhang, Hongwei
    Ma, Luyao
    Ma, Lina
    Hua, Marti Z.
    Wang, Shuo
    Lu, Xiaonan
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2017, 243 : 64 - 69