Mid- and near-infrared determination of metribuzin in agrochemicals

被引:27
|
作者
Khanmohammadi, M. [2 ]
Armenta, Sergio [1 ]
Garrigues, Salvador [1 ]
de la Guardia, Miguel [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
[2] Imam Khomeini Int Univ, Fac Sci, Dept Chem, Gazvin, Iran
关键词
metribuzin; FT-MIR; FF-NIR; pesticide formulations; agrochemicals;
D O I
10.1016/j.vibspec.2007.10.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two infrared-based methodologies were developed for metribuzin determination in pesticide formulations after extraction with acetonitrile. Fourier transform mid infrared (MIR) procedure was based on peak area measurements between 1692 and 1670 cm(-1) corrected with a baseline fixed at 1877 cm(-1). Fourier transform near infrared (NIR) determination was made by measuring the peak area between 6498 and 6332 cm(-1) corrected using a two points baseline defined between 6570 and 6212 cm(-1). Repeatability, as relative standard deviation, of 5 independent measurements at mg g(-1) concentration level was 0.3% and 0.03% for MIR and NIR, respectively, and limit of detection values of 9 and 17 mg kg(-1) in the solid sample were obtained for MIR and NIR, respectively. NIR determination provides a measurement sample frequency of 120 h(-1), higher than that found by MIR and reference chromatography methods (60 and 10 h-1, respectively). On the other hand, the NIR method reduces the solvent consumption and waste generation, to only 10.5 ml acetonitrile per sample as compared with 16.5 ml required for MIR and 66 ml used in the chromatography reference procedure. However the mean accuracy relative error obtained for the analysis of commercial samples was 0.7 and 2.9% (w/w) for MIR and NIR procedures, respectively as compared with data found by the reference procedure, being thus more accurate the MIR than the NIR methodology. So, vibrational procedures, employing a non-chlorinated solvent, such as acetonitrile, for the extraction of the active principle, can be considered serious alternatives to sensitive but expensive reagents and time consuming chromatography methods usually recommended for quality control of agrochemicals. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [41] Optical properties of organic semiconductors based on erbium phthalocyanine complexes in the mid- and near-infrared spectral regions
    Belogorokhov, I. A.
    Tikhonov, E. V.
    Breusova, M. O.
    Pushkarev, V. E.
    Tomilova, L. G.
    Khokhlov, D. R.
    SEMICONDUCTORS, 2007, 41 (10) : 1204 - 1208
  • [42] Detection Limits for Blood on Four Fabric Types Using Infrared Diffuse Reflection Spectroscopy in Mid- and Near-Infrared Spectral Windows
    DeJong, Stephanie A.
    Lu, Zhenyu
    Cassidy, Brianna M.
    O'Brien, Wayne L.
    Morgan, Stephen L.
    Myrick, Michael L.
    ANALYTICAL CHEMISTRY, 2015, 87 (17) : 8740 - 8747
  • [43] Determination of API Gravity and Total and Basic Nitrogen Content by Mid- and Near-Infrared Spectroscopy in Crude Oil with Multivariate Regression and Variable Selection Tools
    Rainha, Karla Pereira
    do Carmo Rocha, Julia Tristao
    Tavares Rodrigues, Rayza Rosa
    de Oliveira Lovatti, Betina Pires
    Ribeiro de Castro, Eustaquio Vinicius
    Filgueiras, Paulo Roberto
    ANALYTICAL LETTERS, 2019, 52 (18) : 2914 - 2930
  • [44] Revisiting the Aqueous Solutions of Dimethyl Sulfoxide by Spectroscopy in the Mid- and Near-Infrared: Experiments and Car-Parrinello Simulations
    Wallace, Victoria M.
    Dhumal, Nilesh R.
    Zehentbauer, Florian M.
    Kim, Hyung J.
    Kiefer, Johannes
    JOURNAL OF PHYSICAL CHEMISTRY B, 2015, 119 (46): : 14780 - 14789
  • [45] Minerals and essential amino acids of bovine colostrum: Phenotypic variability and predictive ability of mid- and near-infrared spectroscopy
    Goi, A.
    De Marchi, M.
    Costa, A.
    JOURNAL OF DAIRY SCIENCE, 2023, 106 (12) : 8341 - 8356
  • [46] Comparing the direct assessment of steatosis in liver explants with mid- and near-infrared vibrational spectroscopy, prior to organ transplantation
    Rienda, Ivan
    Moro, Erika
    Perez-Rubio, Alvaro
    Trullenque-Juan, Ramon
    Perez-Guaita, David
    Lendl, Bernhard
    Kuligowski, Julia
    Castell, Jose V.
    Perez-Rojas, Judith
    Pareja, Eugenia
    Quintas, Guillermo
    ANALYST, 2023, 148 (17) : 3986 - 3991
  • [47] Recent advances in mid- and near-infrared spectroscopy with applications for research and teaching, focusing on petrochemistry and biotechnology relevant products
    Heise, H. M.
    Fritzsche, J.
    Tkatsch, H.
    Waag, F.
    Karch, K.
    Henze, K.
    Delbeck, S.
    Budde, J.
    EUROPEAN JOURNAL OF PHYSICS, 2013, 34 (06) : S139 - S159
  • [48] Detection of HCl molecules by resonantly enhanced sum-frequency mixing of mid- and near-infrared laser pulses
    Moneke, Benedikt
    Kinder, Jan Frederic
    Ernst, Oskar
    Halfmann, Thomas
    PHYSICAL REVIEW A, 2023, 107 (01)
  • [49] Use of mid- and near-infrared spectroscopy to track degradation of bio-based eating utensils during composting
    Mulbry, Walter
    Reeves, James B.
    Millner, Patricia
    BIORESOURCE TECHNOLOGY, 2012, 109 : 93 - 97
  • [50] Techniques and Instrumentation in Near-Infrared and Mid-Infrared Polarimetry
    Jones, T. J.
    ASTRONOMICAL POLARIMETRY 2008: SCIENCE FROM SMALL TO LARGE TELESCOPES, 2011, 449 : 3 - 8