Global Innervation Zone Identification With High-Density Surface Electromyography

被引:11
|
作者
Zhang, Chuan [1 ]
Dias, Nicholas [1 ]
He, Jinbao [2 ]
Zhou, Ping [3 ]
Li, Sheng [3 ]
Zhang, Yingchun [1 ]
机构
[1] Univ Houston, Dept Biomed Engn, Houston, TX 77204 USA
[2] Ningbo Univ Technol, Sch Elect & Informat Engn, Ningbo, Peoples R China
[3] Univ Texas Hlth Sci Ctr Houston, Dept Phys Med & Rehabil, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
Imaging; Electromyography; Sensors; Band-pass filters; Neuromuscular; Three-dimensional displays; Functional imaging; muscle; inverse methods; innervation zone; surface electromyography; EXTERNAL ANAL-SPHINCTER; LOCATION; REPEATABILITY; CONTRACTION; RECORDINGS; VELOCITY; POSITION;
D O I
10.1109/TBME.2019.2919906
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The aim of this study is to compare the performance of three strategies in determining the global innervation zone (IZ) distribution. Methods: High-density surface electromyography was recorded from the biceps brachii muscle of seven healthy subjects under isometric voluntary contractions at 20%, 50%, and 100% of the maximal voluntary contraction and supramaximal musculocutaneous nerve stimulations. IZs were detected: first, by visual identification in a column-specific manner (IZ-1D); second, based on decomposed bipolar mapping of motor unit action potentials (IZ-2D); and third, by source imaging in the three-dimensional muscle space (IZ-3D). Results: All three IZ detection approaches have exhibited excellent trial-to-trial repeatability. Consistent IZ results were found in the axial direction of the arm across all three approaches, yet a difference was observed in the mediolateral direction. Conclusions: Among all three approaches, IZ-3D is capable of providing the most comprehensive information regarding the global IZ distribution, while maintaining high consistency with IZ-1D and IZ-2D results. Significance: IZ-3D approach can be a potential tool for global IZ imaging, which is critical to the clinical diagnosis and treatment of neuromuscular disorders.
引用
收藏
页码:718 / 725
页数:8
相关论文
共 50 条
  • [11] ASSESSMENT OF INNERVATION SYMMETRY OF EXTERNAL ANAL SPHINCTER IN YOUNG AND ELDERLY FEMALES USING HIGH-DENSITY SURFACE ELECTROMYOGRAPHY RECORDINGS
    Dias, Nicholas
    Li, Xuhong
    Zhang, Chuan
    He, Jinbao
    Zhang, Yingchun
    NEUROUROLOGY AND URODYNAMICS, 2018, 37 : S565 - S566
  • [12] Improving the identification of finger movements using high-density surface electromyography pre-processed with PCA
    Yang, Dandan
    Wu, Xiaoying
    Li, Zhengyi
    Zhou, Hui
    Zhou, Dao
    Guan, Jinan
    Xie, Shuiqing
    Hou, Wensheng
    2020 13TH INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND DESIGN (ISCID 2020), 2020, : 249 - 252
  • [13] Semi-Automated Identification of Motor Units Concurrently Recorded in High-Density Surface and Intramuscular Electromyography
    Yeung, Dennis
    Negro, Francesco
    Vujaklija, Ivan
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [14] Proportional estimation of finger movements from high-density surface electromyography
    Nicolò Celadon
    Strahinja Došen
    Iris Binder
    Paolo Ariano
    Dario Farina
    Journal of NeuroEngineering and Rehabilitation, 13
  • [15] Motor unit number estimation using high-density surface electromyography
    van Dijk, Johannes P.
    Blok, Joleen H.
    Lapatki, Bernd G.
    van Schaik, Ivo N.
    Zwarts, Machiel J.
    Stegeman, Dick F.
    CLINICAL NEUROPHYSIOLOGY, 2008, 119 (01) : 33 - 42
  • [16] Proportional estimation of finger movements from high-density surface electromyography
    Celadon, Nicolo
    Dosen, Strahinja
    Binder, Iris
    Ariano, Paolo
    Farina, Dario
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2016, 13
  • [17] A Pilot Study on Quantifying Signal Quality in High-Density Surface Electromyography
    Farago, Emma
    Chan, Adrian D. C.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [18] High-density surface electromyography: A visualization method of laryngeal muscle activity
    Bracken, David J.
    Ornelas, Gladys
    Coleman, Todd P.
    Weissbrod, Philip A.
    LARYNGOSCOPE, 2019, 129 (10): : 2347 - 2353
  • [19] A Wearable Wireless Armband Sensor for High-Density Surface Electromyography Recording
    Tam, S.
    Bilodeau, G.
    Brown, J.
    Gagnon-Turcotte, G.
    Campeau-Lecours, A.
    Gosselin, B.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6040 - 6044
  • [20] Identifying Motor Units in Longitudinal Studies with High-Density Surface Electromyography
    Martinez-Valdes, Eduardo
    Negro, Francesco
    Laine, Christopher M.
    Falla, Deborah L.
    Mayer, Frank
    Farina, Dario
    CONVERGING CLINICAL AND ENGINEERING RESEARCH ON NEUROREHABILITATION II, VOLS 1 AND 2, 2017, 15 : 147 - 151