Parametric analysis of the phase change material wall combining with micro-channel heat pipe and sky radiative cooling technology

被引:33
|
作者
Yu, Cairui [1 ,2 ]
Shen, Dongmei [2 ]
He, Wei [1 ]
Hu, Zhongting [1 ]
Zhang, Sheng [1 ]
Chu, Wenfeng [1 ]
机构
[1] Hefei Univ Technol, Dept Bldg Environm & Equipment, Hefei 230009, Anhui, Peoples R China
[2] West Anhui Univ, Dept Architecture & Civil Engn, Luan 237012, Anhui, Peoples R China
基金
安徽省自然科学基金;
关键词
Parameter analysis; Micro-channel heat pipe; sky radiative cooling; Phase change material; Building energy-saving; THERMAL PERFORMANCE; ENERGY-STORAGE; PCM; SYSTEM; EFFICIENCY; WALLBOARD; ROOF;
D O I
10.1016/j.renene.2021.07.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To address the problem of heat removal by phase change material (PCM) wall at nighttime in the summer season, a new cooling wall that makes use of the high latent heats of PCMs, the high heat conductivities of micro-channel heat pipes (MHPs), and the passive cooling of sky radiative cooling (RC) is introduced, and is named the MHP-RC-PCM wall. In this study, preliminary experiments were first conducted to determine the emissivity of the radiative plate and the properties of PCMs (paraffin, RT28HC). Next, numerical models of the MHP-RC-PCM wall were established to simulate the thermal behavior, and the model was validated with the experimental results. The parameters that affect the thermal behavior of the MHP-RC-PCM wall, including the phase transition temperature, latent heat of the PCM, number of MHPs, and year-round thermal behavior were investigated. The results showed that the phase transition temperature (T-m) of the PCM had a significant influence on the interior surface temperature, liquid fraction and cooling load reduction ratio of the MHP-RC-PCM wall, whereas the PCM latent heat had little effect. The cooling load reduction ratio was approximately 4% for T-m = 31 degrees C, which was higher than that for T-m = 26 degrees C. In addition, it was determined that the year-round energy-saving of the MHP-RC-PCM wall were approximately 18.2% greater than that of the Brick wall with the same thickness, and 0.4% higher than that of PCM wall in Guangzhou City, China. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1057 / 1069
页数:13
相关论文
共 50 条
  • [21] Experimental investigation of a novel micro-channel flat loop heat pipe (MC-FLHP) for data center cooling and heat recovery
    Xiang, Jinwei
    Luo, Liang
    Wang, Xupeng
    Shittu, Samson
    Wang, Zhangyuan
    Zhao, Xudong
    Weng, Chuangbin
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2022, 19 (12) : 1318 - 1332
  • [22] CHF determination for high-heat flux phase change cooling system incorporating both micro-channel flow and jet impingement
    Sung, Myung Ki
    Mudawar, Issam
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (3-4) : 610 - 619
  • [23] Experimental study and exergy analysis of photovoltaic-thermoelectric with flat plate micro-channel heat pipe
    Shittu, Samson
    Li, Guiqiang
    Zhao, Xudong
    Zhou, Jinzhi
    Ma, Xiaoli
    Akhlaghi, Yousef Golizadeh
    ENERGY CONVERSION AND MANAGEMENT, 2020, 207
  • [24] Numerical simulation and optimization of compact latent heat exchanger with micro-channel plate in shape-stabilized composite phase change material
    Zhou, Weiguan
    He, Yangjing
    Xu, Qing
    Wang, Changjun
    Ling, Ziye
    Zhang, Zhengguo
    Fang, Xiaoming
    APPLIED THERMAL ENGINEERING, 2024, 245
  • [25] Improving thermal performance of micro heat pipe arrays by integration of phase change material
    Zhang, Xuan
    Wu, Suchen
    Zhang, Chengbin
    JOURNAL OF ENERGY STORAGE, 2025, 118
  • [26] Analysis of the Transient Single-Phase Thermal Performance of Micro-Channel Heat Sinks
    Joyce, Gavin
    Soliman, Hassan M.
    HEAT TRANSFER ENGINEERING, 2009, 30 (13) : 1058 - 1067
  • [27] A quasi-three-dimensional distributed parameter model of micro-channel separated heat pipe applied for cooling telecommunication cabinets
    Xia, Guanghui
    Zhuang, Dawei
    Ding, Guoliang
    Lu, Jingchao
    APPLIED ENERGY, 2020, 276 (276)
  • [28] Experimental Heat Transfer Enhancement for Single Phase Liquid Micro-Channel Cooling Using A Micro-Synthetic Jet Actuator
    Fang, Ruixian
    Jiang, Wei
    Khan, Jamil
    Dougal, Roger
    PROCEEDINGS OF THE ASME MICRO/NANOSCALE HEAT AND MASS TRANSFER INTERNATIONAL CONFERENCE, VOL 3, 2010, : 199 - 206
  • [29] Numerical analysis of natural convection of magnetohydrodynamic flow in vertical micro-channel with rarefaction effects and radiative heat transfer
    Jamalabadi, Mohammad Yaghoub Abdollahzadeh
    Kim, Se Won
    Lee, Chang Yeop
    Park, Jae Hyun
    ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (04): : 1 - 10
  • [30] Modeling analysis on the cooling efficiency of composite phase change material-heat pipe coupling system in battery pack
    Tang, Ziyi
    Feng, Renlang
    Huang, Peifeng
    Bai, Zhonghao
    Wang, Qingsong
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2022, 78