A smartphone-based device for simultaneous measurement of ratiometric fluorescence and absorbance demonstrated by the determination of hypochlorous acid

被引:1
|
作者
Dou, Jianzhi [1 ]
Shen, Qirui [2 ]
Yang, Yan [2 ]
Song, Haiyan [2 ]
Shen, Dazhong [2 ]
机构
[1] Weifang Engn Vocat Coll, Sch Appl Chem Food & Drug, Qingzhou 262500, Peoples R China
[2] Shandong Normal Univ, Collaborat Innovat Ctr Functionalized Probes Chem, Coll Chem Chem Engn & Mat Sci, Jinan 250014, Peoples R China
基金
中国国家自然科学基金;
关键词
FIELD ANALYSIS; QUANTUM DOTS; LIVING CELLS; CHROMIUM; HEXAVALENT; ABSORPTION; PROBE;
D O I
10.1039/d2nj03106j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Multi-signal assays can improve the accuracy of determinations by integrating the merits of each analytical signal. In the widely used fluorometric and colorimetric dual-mode, the fluorescence intensity and absorbance are measured, respectively, using a fluorophotometer and a spectrophotometer. Herein, we developed a smartphone-based portable device by sandwiching a fluorescence cuvette between two Perspex right-angle trapezoidal cubes, which can measure simultaneously the ratiometric fluorescence and absorbance. Under the irradiation of the excitation light, the fluorescence intensity of the test solution in the cuvette and the intensities of the incident and transmitted light were measured from one picture. According to the intensity ratio of the fluorescence and incident light, the ratiometric fluorescence signal was obtained. The absorbance of the test solution was estimated from the brightness ratio of two trapezoidal cubes. The applicability of the dual-mode portable device was demonstrated by the determination of hypochlorous acid using a heptamethine cyanine-based probe. The limits of detection of the ratiometric fluorescence and absorbance modes for the determinations of HClO are 0.011 and 0.13 mu M, respectively, with the detectable concentration range of 0.02-10 mu M in the dual-mode. The absorbance can be used to monitor the influence of the inner filter effect at the excitation wavelength on the ratiometric fluorescence intensity.
引用
收藏
页码:17487 / 17495
页数:9
相关论文
共 50 条
  • [41] Design and Implementation of a Smartphone-Based Portable Ultrasound Pulsed-Wave Doppler Device for Blood Flow Measurement
    Huang, Chih-Chung
    Lee, Po-Yang
    Chen, Pay-Yu
    Liu, Ting-Yu
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (01) : 182 - 188
  • [42] A ratiometric fluorescence sensor for ascorbic acid determination based on an AND-NAND logic pair
    Zhang, Zilong
    Long, Dengying
    Yang, Mei
    Chang, Xiaojuan
    Xian, Hong
    Chen, Jun
    Peng, Huanjun
    Peng, Jingdong
    MICROCHIMICA ACTA, 2021, 188 (11)
  • [43] A ratiometric fluorescence sensor for ascorbic acid determination based on an AND-NAND logic pair
    Zilong Zhang
    Dengying Long
    Mei Yang
    Xiaojuan Chang
    Hong Xian
    Jun Chen
    Huanjun Peng
    Jingdong Peng
    Microchimica Acta, 2021, 188
  • [44] Micropaper-based analytical device (μPAD) for the simultaneous determination of nitrite and fluoride using a smartphone
    Vidal, Ezequiel
    Lorenzetti, Anabela S.
    Lista, Adriana G.
    Domini, Claudia E.
    MICROCHEMICAL JOURNAL, 2018, 143 : 467 - 473
  • [45] Cleavable hairpin beacon-enhanced fluorescence detection of nucleic acid isothermal amplification and smartphone-based readout
    Ding, Xiong
    Yin, Kun
    Li, Ziyue
    Pandian, Vikram
    Smyth, Joan A.
    Helal, Zeinab
    Liu, Changchun
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [46] Cleavable hairpin beacon-enhanced fluorescence detection of nucleic acid isothermal amplification and smartphone-based readout
    Xiong Ding
    Kun Yin
    Ziyue Li
    Vikram Pandian
    Joan A. Smyth
    Zeinab Helal
    Changchun Liu
    Scientific Reports, 10
  • [47] Smartphone-based photochemical sensor for multiplex determination of glucose, uric acid, and total cholesterol in fingertip blood
    Duan, Wenfang
    Cheng, Jie
    Guo, Jinhong
    ANALYST, 2022, 147 (14) : 3285 - 3290
  • [48] Smartphone-based non-invasive detection of salivary uric acid based on the fluorescence quenching of gleditsia sinensis carbon dots
    Xiang, Yujuan
    Yu, Hongpeng
    Wu, Kegang
    Quan, Ziting
    He, Dong
    Ou, Cansheng
    Chai, Xianghua
    Liang, Yinglin
    Duan, Xuejuan
    Zhang, Xiangyu
    Zha, Qin
    Xie, Wei
    MICROCHIMICA ACTA, 2025, 192 (02)
  • [49] Intelligent Platform for Simultaneous Detection of Multiple Aminoglycosides Based on a Ratiometric Paper-Based Device with Digital Fluorescence Detector Readout
    Wang, Lumin
    Zhu, Fawei
    Zhu, Yuqiu
    Xie, Siqi
    Chen, Miao
    Xiong, Yu
    Liu, Qi
    Yang, Hua
    Chen, Xiaoqing
    ACS SENSORS, 2019, 4 (12) : 3283 - 3290
  • [50] Point-of-need quantitation of 2,4-dichlorophenoxyacetic acid using a ratiometric fluorescent nanoprobe and a smartphone-based sensing system
    Liu, Yun
    Xiao, Meng
    Xu, Ningxia
    Yang, Mengsu
    Yi, Changqing
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 367