Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis

被引:136
|
作者
Zhelev, Zhivko [1 ]
Hyde, Christopher [1 ]
Youngman, Emily [1 ]
Rogers, Morwenna [1 ]
Fleming, Simon [2 ]
Slade, Toby [3 ]
Coelho, Helen [1 ]
Jones-Hughes, Tracey [1 ]
Nikolaou, Vasilis [1 ]
机构
[1] Univ Exeter, Sch Med, Inst Hlth Res, Exeter, Devon EX2 4SG, England
[2] Royal Cornwall Hosp, Truro TQ1 3LQ, England
[3] Royal Cornwall Hosp, Emergency Dept, Truro TQ1 3LQ, England
来源
关键词
CORONARY-ARTERY-DISEASE; EARLY RULE-OUT; CARDIAC TROPONIN; RELATIVE CHANGES; RAPID RULE; COPEPTIN; PERFORMANCE; ABSOLUTE; PROTEIN; UTILITY;
D O I
10.1136/bmj.h15
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To obtain summary estimates of the accuracy of a single baseline measurement of the Elecsys Troponin T high-sensitive assay (Roche Diagnostics) for the diagnosis of acute myocardial infarction in patients presenting to the emergency department. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Medline, Embase, and other relevant electronic databases were searched for papers published between January 2006 and December 2013. Study selection Studies were included if they evaluated the diagnostic accuracy of a single baseline measurement of Elecsys Troponin T high-sensitive assay for the diagnosis of acute myocardial infarction in patients presenting to the emergency department with suspected acute coronary syndrome. Study appraisal and data synthesis The first author screened all titles and abstracts identified through the searches and selected all potentially relevant papers. The screening of the full texts, the data extraction, and the methodological quality assessment, using the adapted QUADAS-2 tool, were conducted independently by two reviewers with disagreements being resolved through discussion or arbitration. If appropriate, meta-analysis was conducted using the hierarchical bivariate model. Results Twenty three studies reported the performance of the evaluated assay at presentation. The results for 14 ng/L and 3-5 ng/L cut-off values were pooled separately. At 14 ng/L (20 papers), the summary sensitivity was 89.5% (95% confidence interval 86.3% to 92.1%) and the summary specificity was 77.1% (68.7% to 83.7%). At 3-5 ng/L (six papers), the summary sensitivity was 97.4% (94.9% to 98.7%) and the summary specificity was 42.4% (31.2% to 54.5%). This means that if 21 of 100 consecutive patients have the target condition (21%, the median prevalence across the studies), 2 (95% confidence interval 2 to 3) of 21 patients with acute myocardial infarction will be missed (false negatives) if 14 ng/L is used as a cut-off value and 18 (13 to 25) of 79 patients without acute myocardial infarction will test positive (false positives). If the 3-5 ng/L cut-off value is used, < 1 (0 to 1) patient with acute myocardial infarction will be missed and 46 (36 to 54) patients without acute myocardial infarction will test positive. Conclusions The results indicate that a single baseline measurement of the Elecsys Troponin T high-sensitive assay could be used to rule out acute myocardial infarction if lower cut-off values such as 3 ng/L or 5 ng/L are used. However, this method should be part of a comprehensive triage strategy and may not be appropriate for patients who present less than three hours after symptom onset. Care must also be exercised because of the higher imprecision of the evaluated assay and the greater effect of lot-to-lot reagent variation at low troponin concentrations. Systematic review registration PROSPERO registration number CRD42013003926.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Diagnostic accuracy of neuroimaging in emergency department patients with acute vertigo or dizziness: A systematic review and meta-analysis for the guidelines for reasonable and appropriate care in the emergency department
    Shah, Vishal Paresh
    e Silva, Lucas Oliveira J.
    Farah, Wigdan
    Seisa, Mohamad
    Balla, Abdalla Kara
    Christensen, April
    Farah, Magdoleen
    Hasan, Bashar
    Bellolio, Fernanda
    Murad, M. Hassan
    ACADEMIC EMERGENCY MEDICINE, 2023, 30 (05) : 517 - 530
  • [32] Use of copeptin and high-sensitive cardiac troponin T for diagnosis and prognosis in patients with diabetes mellitus and suspected acute myocardial infarction
    Zellweger, C.
    Wildi, K.
    Twerenbold, R.
    Reichlin, T.
    Naduvilekoot, A.
    Neuhaus, J. D.
    Balmelli, C.
    Gabutti, M.
    Al Afify, A.
    Ballarino, P.
    Jaeger, C.
    Druey, S.
    Hillinger, P.
    Haaf, P.
    Vilaplana, C.
    Darbouret, B.
    Ebmeyer, S.
    Gimenez, M. Rubini
    Moehring, B.
    Osswald, S.
    Mueller, C.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 190 : 190 - 197
  • [33] Profile of Roche's Elecsys Troponin T Gen 5 STAT blood test (a high-sensitivity cardiac troponin assay) for diagnosing myocardial infarction in the emergency department
    Kavsak, Peter A.
    Andruchow, James E.
    McRae, Andrew D.
    Worster, Andrew
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2018, 18 (06) : 481 - 489
  • [34] Diagnostic accuracy of combined cardiac troponin and copeptin assessment for early rule-out of myocardial infarction: a systematic review and meta-analysis
    Raskovalova, Tatiana
    Twerenbold, Raphael
    Collinson, Paul O.
    Keller, Till
    Bouvaist, Helene
    Folli, Christian
    Giavarina, Davide
    Lotze, Ulrich
    Eggers, Kai M.
    Dupuy, Anne-Marie
    Chenevier-Gobeaux, Camille
    Meune, Christophe
    Maisel, Alan
    Mueller, Christian
    Labarere, Jose
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2014, 3 (01) : 18 - 27
  • [35] Diagnostic accuracy of abdominal ultrasound for diagnosis of acute appendicitis: systematic review and meta-analysis
    Le Conte, P.
    ANNALES FRANCAISES DE MEDECINE D URGENCE, 2018, 8 (03): : 207 - 208
  • [36] Non-acute myocardial infarction-related causes of elevated high-sensitive troponin T in the emergency room: a cross-sectional analysis
    Gregor Lindner
    Carmen Andrea Pfortmueller
    Christian Tasso Braun
    Aristomenis Konstantinos Exadaktylos
    Internal and Emergency Medicine, 2014, 9 : 335 - 339
  • [37] Non-acute myocardial infarction-related causes of elevated high-sensitive troponin T in the emergency room: a cross-sectional analysis
    Lindner, Gregor
    Pfortmueller, Carmen Andrea
    Braun, Christian Tasso
    Exadaktylos, Aristomenis Konstantinos
    INTERNAL AND EMERGENCY MEDICINE, 2014, 9 (03) : 335 - 339
  • [38] Diagnostic Accuracy of Abdominal Ultrasound for Diagnosis of Acute Appendicitis: Systematic Review and Meta-analysis
    Vanja Giljaca
    Tin Nadarevic
    Goran Poropat
    Vesna Stefanac Nadarevic
    Davor Stimac
    World Journal of Surgery, 2017, 41 : 693 - 700
  • [39] DIAGNOSTIC ACCURACY OF ABDOMINAL ULTRASOUND FOR DIAGNOSIS OF ACUTE APPENDICITIS: SYSTEMATIC REVIEW AND META-ANALYSIS
    Giljaca, V.
    Nadarevic, T.
    Poropat, G.
    Nadarevic, V. Stefanac
    Stimac, D.
    GUT, 2017, 66 : A140 - A140
  • [40] Diagnostic Accuracy of Abdominal Ultrasound for Diagnosis of Acute Appendicitis: Systematic Review and Meta-analysis
    Giljaca, Vanja
    Nadarevic, Tin
    Poropat, Goran
    Nadarevic, Vesna Stefanac
    Stimac, Davor
    WORLD JOURNAL OF SURGERY, 2017, 41 (03) : 693 - 700