Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis

被引:136
|
作者
Zhelev, Zhivko [1 ]
Hyde, Christopher [1 ]
Youngman, Emily [1 ]
Rogers, Morwenna [1 ]
Fleming, Simon [2 ]
Slade, Toby [3 ]
Coelho, Helen [1 ]
Jones-Hughes, Tracey [1 ]
Nikolaou, Vasilis [1 ]
机构
[1] Univ Exeter, Sch Med, Inst Hlth Res, Exeter, Devon EX2 4SG, England
[2] Royal Cornwall Hosp, Truro TQ1 3LQ, England
[3] Royal Cornwall Hosp, Emergency Dept, Truro TQ1 3LQ, England
来源
关键词
CORONARY-ARTERY-DISEASE; EARLY RULE-OUT; CARDIAC TROPONIN; RELATIVE CHANGES; RAPID RULE; COPEPTIN; PERFORMANCE; ABSOLUTE; PROTEIN; UTILITY;
D O I
10.1136/bmj.h15
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To obtain summary estimates of the accuracy of a single baseline measurement of the Elecsys Troponin T high-sensitive assay (Roche Diagnostics) for the diagnosis of acute myocardial infarction in patients presenting to the emergency department. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Medline, Embase, and other relevant electronic databases were searched for papers published between January 2006 and December 2013. Study selection Studies were included if they evaluated the diagnostic accuracy of a single baseline measurement of Elecsys Troponin T high-sensitive assay for the diagnosis of acute myocardial infarction in patients presenting to the emergency department with suspected acute coronary syndrome. Study appraisal and data synthesis The first author screened all titles and abstracts identified through the searches and selected all potentially relevant papers. The screening of the full texts, the data extraction, and the methodological quality assessment, using the adapted QUADAS-2 tool, were conducted independently by two reviewers with disagreements being resolved through discussion or arbitration. If appropriate, meta-analysis was conducted using the hierarchical bivariate model. Results Twenty three studies reported the performance of the evaluated assay at presentation. The results for 14 ng/L and 3-5 ng/L cut-off values were pooled separately. At 14 ng/L (20 papers), the summary sensitivity was 89.5% (95% confidence interval 86.3% to 92.1%) and the summary specificity was 77.1% (68.7% to 83.7%). At 3-5 ng/L (six papers), the summary sensitivity was 97.4% (94.9% to 98.7%) and the summary specificity was 42.4% (31.2% to 54.5%). This means that if 21 of 100 consecutive patients have the target condition (21%, the median prevalence across the studies), 2 (95% confidence interval 2 to 3) of 21 patients with acute myocardial infarction will be missed (false negatives) if 14 ng/L is used as a cut-off value and 18 (13 to 25) of 79 patients without acute myocardial infarction will test positive (false positives). If the 3-5 ng/L cut-off value is used, < 1 (0 to 1) patient with acute myocardial infarction will be missed and 46 (36 to 54) patients without acute myocardial infarction will test positive. Conclusions The results indicate that a single baseline measurement of the Elecsys Troponin T high-sensitive assay could be used to rule out acute myocardial infarction if lower cut-off values such as 3 ng/L or 5 ng/L are used. However, this method should be part of a comprehensive triage strategy and may not be appropriate for patients who present less than three hours after symptom onset. Care must also be exercised because of the higher imprecision of the evaluated assay and the greater effect of lot-to-lot reagent variation at low troponin concentrations. Systematic review registration PROSPERO registration number CRD42013003926.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Diagnostic accuracy of sensitive or high-sensitive troponin on presentation for myocardial infarction: a meta-analysis and systematic review
    Sethi, Ankur
    Bajaj, Anurag
    Malhotra, Gurveen
    Arora, Rohit R.
    Khosla, Sandeep
    VASCULAR HEALTH AND RISK MANAGEMENT, 2014, 10 : 435 - 450
  • [2] High-sensitive Troponin T assay for the diagnosis of acute myocardial infarction: an economic evaluation
    Vaidya, Anil
    Severens, Johan L.
    Bongaerts, Brenda W. C.
    Cleutjens, Kitty B. J. M.
    Nelemans, Patty J.
    Hofstra, Leonard
    van Dieijen-Visser, Marja
    Biessen, Erik A. L.
    BMC CARDIOVASCULAR DISORDERS, 2014, 14
  • [3] High-sensitive Troponin T assay for the diagnosis of acute myocardial infarction: an economic evaluation
    Anil Vaidya
    Johan L Severens
    Brenda WC Bongaerts
    Kitty BJM Cleutjens
    Patty J Nelemans
    Leonard Hofstra
    Marja van Dieijen-Visser
    Erik AL Biessen
    BMC Cardiovascular Disorders, 14
  • [4] Early diagnostic and prognostic utility of high-sensitive troponin assays in acute myocardial infarction: a meta-analysis
    Li, W. -J.
    Chen, X. -M.
    Nie, X. -Y.
    Lin, X. -X.
    Cheng, Y. -J.
    Hu, C. -H.
    Du, Z. -M.
    Dong, Y. -G.
    Ma, H.
    Wu, S. -H.
    INTERNAL MEDICINE JOURNAL, 2015, 45 (07) : 748 - 756
  • [5] Performance of a sensitive troponin assay in the early diagnosis of acute myocardial infarction in the emergency department
    Kelly, Anne-Maree
    EMERGENCY MEDICINE AUSTRALASIA, 2011, 23 (02) : 181 - 185
  • [6] Effect of age and gender differences on high-sensitive troponin T measurement in the diagnosis of acute myocardial infarction
    Isiksacan, Nilgun
    Biyik, Ismail
    Opan, Selcuk
    Caglar, Fatma N. T.
    Erturk, Mehmet
    Yazan, Serkan
    Kasapoglu, Pinar
    Karabulut, Dilay
    Kocamaz, Nursel
    Yildirim, Mehmet R.
    Baycan, Omer F.
    Ozalp, Begum
    Karakurt, Huseyin
    Akturk, Ibrahim F.
    JOURNAL OF LABORATORY MEDICINE, 2019, 43 (01) : 35 - 40
  • [7] The diagnostic accuracy of cardiac ultrasound for acute myocardial ischemia in the emergency department: a systematic review and meta-analysis
    Virginia Zarama
    María Camila Arango-Granados
    Ramiro Manzano-Nunez
    James P. Sheppard
    Nia Roberts
    Annette Plüddemann
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 32
  • [8] The diagnostic accuracy of cardiac ultrasound for acute myocardial ischemia in the emergency department: a systematic review and meta-analysis
    Zarama, Virginia
    Arango-Granados, Maria Camila
    Manzano-Nunez, Ramiro
    Sheppard, James P.
    Roberts, Nia
    Pluddemann, Annette
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2024, 32 (01):
  • [9] HIGH-SENSITIVE TROPONIN T ASSAY IN THE DIAGNOSIS OF PERIOPERATIVE MYOCARDIAL INFARCTION AFTER HEART SURVERY
    Maroto Rodriguez, B.
    Gutierrez Rodriguez, J.
    Perez Vela, J. L.
    Arribas Lopez, P.
    Corres Pieretti, M. A.
    Pereales Rodriguez de Viguri, N.
    INTENSIVE CARE MEDICINE, 2012, 38 : S159 - S159
  • [10] SERIAL HIGH-SENSITIVITY CARDIAC TROPONIN T MEASUREMENTS TO RULE OUT ACUTE MYOCARDIAL INFARCTION AND A SINGLE HIGH BASELINE MEASUREMENT FOR SWIFT RULE-IN: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Arslan, Murat
    Dedic, Admir
    Boersma, Eric
    Dubois, Eric A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 282 - 282